steam trap

Transkript

steam trap
SDS U2004-40
STEAM TRAP
MODEL
HR260A
ALLOY STEEL
SUPERCRITICAL SERVICE THERMODYNAMIC DISC TRAP
Features
Air-jacketed disc trap for supercritical
service in high pressure steam mains and
turbines.
1. Inline replaceable valve module for ease of
maintenance and low cost of repair.
2. Lapped disc provides steam-tight seal.
3. Air jacket reduces radiant heat loss to reduce
no-load cycling and so extend life.
4. Built-in screen with large surface area for
extended trouble-free operation.
5. Hardened working surfaces guarantee long
service life.
6. Approved by major power plants worldwide
for supercritical steam use.
Specifications
Model
HR260A
Connection
Pressure-Temperature Rating**
Socket Welded
Butt Welded
DN 15, 25
Size
260
PMO
400
16
Minimum Operating Pressure (barg)
Maximum Operating Temperature (˚C)
TMO
550
Maximum Allowable Pressure (barg)
PMA*
260 @ 550 ˚C
Maximum Allowable Temperature (˚C)
TMA*
TMA (˚C)
Maximum Operating Pressure (barg)
550
500
550 @ 260 barg
1 bar = 0.1 MPa
* PRESSURE SHELL DESIGN CONDITIONS (NOT OPERATING CONDITIONS)
** This Rating Graph is based on Allowable Stress Values of ASTM-Materials at each temperature.
CAUTION
No.
200
100
50% of Inlet Pressure
Maximum Back Pressure
300
0
0
50
100
150
200
PMA (barg)
250
300
To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range.
Local regulations may restrict the use of this product to below the conditions quoted.
Description
DIN*
Material
Alloy Steel A182 F22 Cl.3
1.7380
Alloy Steel (9%Cr - 1%Mo)**
1.4903
ASTM/AISI*
―
1
⃝
Body
2R
⃝
3R
⃝
4R
⃝
5
⃝
6
⃝
7 MR
⃝
8 MR
⃝
9R
⃝
10
⃝
11
⃝
12
⃝
13 R
⃝
14
⃝
15
⃝
Cover
Stainless Steel SUS420J2
1.4031
AISI420
Module Valve Seat
Stainless Steel SUS440C
1.4125
AISI440C
12
Disc
Stainless Steel SUS440C
1.4125
AISI440C
11
Eye Nut
Carbon Steel SS400
1.0037
A6
10
Spacer
Carbon Steel SS400
1.0037
A6
Graphite/Stainl. Stl. SUS309S+Cb
Graphite/Stainl. Stl. SUS309S+Cb
2
Module Gasket
- /1.4833
- /AISI309S+Cb
- /1.4833
7
- /AISI309S+Cb
9
Module Gasket
Screen inside/outside Stainless Steel SUS430/304
―
Body Bolt
Alloy Steel SNB16
1.4016/4301 AISI430/304
1.7711
A193 Gr.B16
Cover Nut
Alloy Steel SNB7
1.7225
A193 Gr.B7
Cap
Carbon Steel SPCC
1.0330
A109
Guide Pin
Stainless Steel SUS304
1.4301
AISI304
Nameplate***
Stainless Steel SUS304
1.4301
AISI304
Hexagon Nut
Carbon Steel SS400
1.0037
A6
* Equivalent materials ** Option *** Not shown
Replacement kits available: (M) maintenance parts, (R) repair parts
5
15
6
4
3
8
13
1
Copyright
C
Consulting & Engineering Service
Dimensions
• HR260A
HR260A Socket Welded*
L
Socket Welded
DN
H1
15
H
25
(mm)
L
H
H1
φD
160
208
179
53.5
h
Weight
(kg)
14
18
φC
21.8
33.9
D
C
* ASME B16.11-2005, other standards available
h
• HR260A
HR260A Butt Welded*
L
Butt Welded
DN
H1
15
H
25
L
H
H1
165
208
179
(mm)
φD
φD1
φd
28
22
16
40
35
27
h
Weight
(kg)
20
18
* DIN 3239 Form C (PN250), other standards available
D
D1
d
30˚
h
Discharge Capacity
Discharge Capacity (kg/h)
250
200
180
160
140
120
100
16
20
30
40
50
60
70
80 90 100
Differential Pressure (bar)
150
200 225
260
1 bar = 0.1 MPa
1. Differential pressure is the difference between the inlet and outlet pressure of the trap.
2. Recommended safety factor: at least 2.
Copyright
(M)
C
SDS U2004-40
Rev. 6/2014
Products for intended use only.
Specifications subject to change without notice.

Benzer belgeler

steam trap

steam trap HR150A Socket Welded*

Detaylı

free float® steam trap

free float® steam trap 2. Differential pressure is the difference between the inlet and outlet pressure of the trap. 3. Capacities are based on continuous discharge of condensate 6 °C below saturated steam temperature. 4...

Detaylı

steam trap

steam trap 5. Built-in screen for trouble-free service. 6. High grade reusable gaskets. 7. Hardened working surfaces for long life.

Detaylı

free float® steam trap

free float® steam trap 2. Differential pressure is the difference between the inlet and outlet pressure of the trap. 3. Capacities are based on continuous discharge of condensate 6 °C below saturated steam temperature.

Detaylı

process float steam trap

process float steam trap * JL14-X has a screwed-in flange ** Optional JLH14-B with bimetal-type air vent unit for initial air venting PRESSURE SHELL DESIGN CONDITIONS (NOT OPERATING CONDITIONS): Maximum Allowable Pressure ...

Detaylı

Specifications

Specifications cleaning and reduces maintenance costs. 5. High-quality stainless steel internals and hardened valve surfaces ensure reliability.

Detaylı

elastomer sitli sürgülü vana (pn 25, f4)

elastomer sitli sürgülü vana (pn 25, f4) Sıcak ve soğuk su sistemleri, asit ve alkali özelliği bulunmayan sıvı akışkanlar Hot and cold water systems, non-acidic and non-flammable liquid fluids

Detaylı

model gp10f cast steel carbon steel

model gp10f cast steel carbon steel Maximum Operating Temperature (˚C)

Detaylı