aqua meter
Transkript
aqua meter
AQUA METER 1. TANIM VE ÖZELL KLER .........................................................................................2 1.1. TANIM ....................................................................................................................2 1.2. ÖZELL KLER ..........................................................................................................2 1.2. TEKN K ÖZELL KLER .............................................................................................3 2. KURULUM ..................................................................................................................4 2.1. GENEL MONTAJ.....................................................................................................4 2.2. ELEKTR K BA LANTISI ..........................................................................................5 2.3. ELEKTROT SEÇ M .................................................................................................5 2.4. ISI SENSÖRÜ ..........................................................................................................6 2.5. ANALOG ÇIKI .......................................................................................................6 2.6. SER HABERLE ME ...............................................................................................6 3. KULLANIM .................................................................................................................7 3.1. GENEL KULLANIM .................................................................................................7 3.2. C HAZ ÇIKI I KONTROL MODUNUN AYARLANMASI ..............................................7 3.3. PARAMETRELER ....................................................................................................8 3.3.1. Parametre De erinin De i tirilmesi......................................................8 3.3.2. Parametre Listesi ......................................................................................9 3.4. KAL BRASYON .....................................................................................................10 3.4.1. pH ve ORP Cihazlarının Kalibrasyonu ...............................................10 3.4.2. Serbest Klor Cihazının Kalibrasyonu .................................................11 3.4.3. letkenlik Cihazının Kalibrasyonu........................................................12 3.5. ÇIKI KONTROL MODLARI ..................................................................................13 3.6. ANALOG ÇIKI MODLARI ....................................................................................13 3.7. SER HABERLE ME .............................................................................................14 3.8. FRE KULLANIMI ................................................................................................14 4. SERV S......................................................................................................................14 5. GARANT VE STANDARTLAR.............................................................................14 6. TEKN K Ç Z MLER .................................................................................................14 06.10.09 Sayfa 1/14 AQUA METER 1. Tanım ve Özellikler 1.1. Tanım AQUA METER cihazı pH, ORP, Klor ve letkenlik olmak üzere dört de i ik de erin ölçümünü yapmak, çe itli çıkı birimlerine dönü türmek ve kontrol etmek amacıyla geli tirilmi Ölçüm Dönü türme ve Kontrol cihazıdır. AQUA METER pH, AQUA METER ORP, AQUA METER Cl, AQUA METER Con olarak adlandırılan bu cihazların her birisi sadece bir birimle ilgilenir. pH ve Con cihazları aynı zamanda ısı ölçümü de yaparak birimlerin ısı kompanzasyonunu da yerine getirir. 1.2. Özellikler • pH, ORP, serbest klor, iletkenlik, ısı için ölçüm, kontrol ve dönü türme cihazı. • Standart kombine elektrodlar ile pH, ORP ölçümü; özel Cl2 elektrodu ile klor ölçümü, standart iletkenlik probu ile iletkenlik ölçümü. • Isı ölçme özelli i ile ölçümlerde ısı kompanzasyonu. • Tampon sıvılar kullanarak ,ayar çubu u, tornavida vb. gerektirmeden tamamen dijital ayarlama ve otomatik kalibrasyon. • RS485 seri ba lantı portu ile bilgisayar, gösterge panelleri ve yazıcı modülü ile do rudan haberle me. • Yüksek çalı ma güvenli i, elektrik izolasyonu, nem, asit ve klor buharına kar ı tam yalıtım. • Kolay ve esnek kurulum. • Mikro kontrolör teknolojisi. • Analog kontrol çıkı ı (0-20mA, 4-20mA, 0-10V 0-5V 1-10V 1-5V ) • Programlanabilir alarm çıkı ı. • Kullanıcı ifresi 06.10.09 Sayfa 2/14 AQUA METER 1.2. Teknik Özellikler Aqua Meter Teknik Özellikler Model Ölçme Aralı ı pH ORP pH 0,00 – 14,00 0 – 50ºC NTC 0 – 100mV Çözünürlük 0,01 pH, 0,1 ºC 1 mV Isı Kompanzasyonu NTC – Pt100 Chlorine 0,01 – 3,00 ppm -25 – +125ºC Pt100 Conductivity 0,01 – 10,00mS 0 – 50ºC NTC -25 – +125º Pt100 0,01 ppm 0,01 mS 0,1 ºC NTC – Pt100 Kontrol Çıkı ı 220V~ 5A 700VA 3P Role Alarm Çıkı ı 220V~ 5A 700VA 3P Role Analog Çıkı 0-5V, 0-10V, 1-5V, 2-10V, 0-10mA, 0-20mA, 2-10mA, 4-20mA Haberle me RS485 Besleme Çalı ma Isısı 220V~ 50 Hz 0 .. 50 ºC Gövde IP65 A ırlık 0,7 Kg Ölçüler 200 x 150 x 100 (G x Y x D) 06.10.09 Sayfa 3/14 AQUA METER 2. Kurulum 2.1. Genel Montaj Cihaz duvara yada bir panele monte edilebilir. Panele monte edilmesi ve monte edilecek yerin iyi havalandırılması önerilir. Özellikle makine dairelerinde asit ve klor nemi çok olaca ı için cihaza zarar verebilir. Bunun için gereken bütün korumalar alınmı olsa da cihazın uzun ömürlü olması için bu gereklidir. Cihaz üst kısmında bulunan montaj elemanı üzerindeki iki adet vida deli i sayesinde monte edilebilir. 06.10.09 Sayfa 4/14 AQUA METER 2.2. Elektrik Ba lantısı AQUA METER Ana Kart Elektrik Ba lantısı Dikkat: Cihazın montajı yada bakımı esnasında besleme akımını kesiniz. Cihazınız 50Hz 220V AC ile çalı ır. ki adet (Kontrol ve Alarm için) röle çıkı ı vardır. Bu çıkı lara max 2.5A yük ba lanabilir. Klemens kapa ı içerisinde terminal ba lantı isimleri kısaltmalar ile belirtilmi tir. Elektronik devre sigorta ile korunmu tur 1A den büyük sigorta kullanılmamalıdır. 2.3. Elektrot Seçimi Cihazın kullandı ı elektrotlar tabloda gösterilmi tir. Ba lantıları BNC konnektör ile yapılır. Cihaz üzerinde hangi elektrotun nereye ba lanaca ı belirtilmi tir. Cihaz Tipi pH ORP Cl Con 06.10.09 Elektrod Tipi Standart Kombine pH Elektrodu Standart Kombine ORP Elektrodu Antech Serbest klor hücresi Antech letkenlik Elektrodu Sayfa 5/14 AQUA METER 2.4. Isı Sensörü AQUA METER pH ve Con cihazları NTC ve Pt100 olmak üzere iki tür ısı sensörünü destekler. Antech ısı sensörleri cihaz üzerindeki ba lantı noktasına direkt olark ba lanabilmektedirler. Ba lantı noktasının detaylı ekli yanda verilmi tir. Isı Sensörü Ba lantısı 2.5. Analog Çıkı Cihaz toplam 8 de i ik analog çıkı verebilmektedir. Cihaz üzerinde bulunan jumperlar vasıtası ile bu çıkı ekillerinden birisi seçilebilir. Analog Çıkı Ba lantısı ve Jumper Ayarları 2.6. Seri Haberle me Cihaz üzerinde bulunan RS 485 seri ba lantı noktası vasıtası ile bilgisayar, yazıcı ve Antech bilgilendirme panelleri ile haberle ebilmektedir. J5 Jumper’ı 120 ohm luk sonlandırma direncini devreye sokmak için yerle tirilmi tir. RS 485 seri haberle me ba lantısı 06.10.09 Sayfa 6/14 AQUA METER 3. Kullanım 3.1. Genel Kullanım Kontrol paneli 4 fonksiyon tu u ve 3 durum ledinden olu maktadır. Parametrelere eri im ve kontrol bu 4 fonksiyon tu u sayesinde gerçekle ir. A a ıda örnek olarak Set parametresinin de i tirilmesi gösterilmi tir. 3.2. Cihaz Çıkı ı Kontrol Modunun Ayarlanması Cihazın çıkı kontrol modu ekranın sa üstünde gösterilir. Üç de i ik durum vardır. OFF : Cihaz çıkı ı sürekli kapalıdır. AUTO : Cihaz çıkı ı ayarlanan de erlere göre otomatik olarak çalı ır. ON : Cihaz çıkı ı sürekli açıktır. Bu durumlar yukarı tu u ile de i tirilir. 06.10.09 Sayfa 7/14 AQUA METER 3.3. Parametreler 3.3.1. Parametre De erinin De i tirilmesi Giri tu una basarak parametrelere ula ılır. Yandaki ekran görülür. Yukarı[ ] ve a a ı[ ] a a ı tu larını kullanarak Set parametresini bulunuz. Soldaki Ekran Giri tu una basarak parametre de erini de i tirme bölümüne giriniz. Yandaki ekran görülür. Yukarı ve a a ı tu ları ile de eri istedi iniz de ere getiriniz. Giri tu u ile de eri kaydedip çıkınız bir üst menüye dönebilirsiniz. [C] tu u bir üst menüye de eri kaydetmeden dönmenizi sa lar. Ana ekrana dönmek için yine [C] tu unu kullanınız. 06.10.09 Sayfa 8/14 AQUA METER 3.3.2. Parametre Listesi 01 02 03 04 05 06 07 Parametre _Device _Temp.Sens. Mode Cont Mode Output Mode Cont. Run Analog Type De er 000-002 000 001 000 001 002 000 001 000 001 000 001 0-30 min 000 001 0-30 000 001 000 001 000 001 000 001 0 - Max** 0 – Max** 08 Temp Comp. 09 10 Log Interv. Pass Enable 11 12 Dev Addr 13 CRC Cont 14 LR 15 HR 16 17 Set Set Ofset 18 Ratio Diff. 0-100 19 20 21 22 23 24 Low Alarm High Alarm Buf Sol 1 Buf Sol 2 pH (Cl) Password 0 – Max** 0 – Max** 0 -Max** 0 -Max** Comm Mode 0-9999 Açıklama Fabrika Ayarı Fabrika Ayarı Çıkı Kontrol Off - Auto - On Role Kontrol Oransal Kontrol Yükseltme Kontrol Dü ürme Kontrol Dü ürme ve Yükseltme Kontrol Run Mode 1 dk sonra Auto Run Mode Oransal Kontrol Çıkı lı Tam Skala Çıkı lı Isı Düzeltme Pasif Isı Düzeltme Aktif Bilgi Gönderme Periyodu ifre Koruma Kapalı ifre Koruma Açık Rs-485 leti im Adresi Rs-485 Slave Mode Rs-485 Master Mode Haberle mede CRC Kontrolü Kapalı Haberle mede CRC Kontrolü Açık Alt limit de er a ımında çıkı pasif Alt limit de er a ımında çıkı aktif Üst limit de er a ımında çıkı pasif Üst limit de er a ımında çıkı aktif Set Noktası Ofset Seviyesi Analog çıkı %100 noktasınıon Set De erinden farkı De er dü ük alarmı De er yüksek alarmı 1. Tampon Sıvı (pH ve ORP cihazlarında) 2. Tampon Sıvı (pH ve ORP cihazlarında) pH de eri (Cl cihazında) ifre Tanımlama ** Max Cihaz tipine göre de i ir. De erler öyledir. pH=14,00 ORP=2000 Cl=3,00 Con=10,00 06.10.09 Sayfa 9/14 AQUA METER 3.4. Kalibrasyon Cihazın kalibrasyonu cihaz tipine göre de i iklik gösterir. pH ve ORP cihazlarını kalibrasyonu aynıdır fakat Cl ve Con cihazları farklıdır. A a ıda her üç kalibrasyon da gösterilmi tir. A a ı [ ] ve yukarı[ ] tu larına aynı anda basılır ise ekranda “Calibration” mesajı görülür ve kalibrasyon menüsüne girilir. 3.4.1. pH ve ORP Cihazlarının Kalibrasyonu Kalibrasyon menüsüne girilince soldaki ekran gelir bu de er Buf.Sol.1 parametresindeki de er için kalibrasyon yapaca ınızı gösterir. Buf.Sol.1 ve Buf.Sol.2 parametreleri daha önceden elinizdeki tampon sıvılara göre ayarlanmalıdır. Bizim örne imizde pH 4.00 ve pH 7.00 tampon sıvıları kullanılacaktır. Ve parametre menüsüne girilerek daha önceden sisteme tanıtılmı tır. Bu ekran gelince elektrot sıvıya daldırılır ve ekrandaki de erin hareketsiz hale gelmesi beklenir. Hareket durunca Giri tu una basılarak ikinci tampon sıvıya geçilir. NOT :Elektrot ikinci tampon sıvıya daldırmadan önce mutlaka saf su ile temizlenmelidir. Bu defa elektrot ikinci tampon sıvıya daldırılır ve yine ekrandaki de erin hareketsiz hale gelmesi beklenir. Hareket durunca yine Giri tu una basılarak kalibrasyon i lemi tamamlanır. E er kalibrasyon de erleri sorunsuz ise soldaki mesaj görülür ve kalibrasyon de erleri kaydedilir. E er kalibrasyon de erleri kabul edilebilir sınırlar içinde de il ise bu defa hata mesajı görülür ve cihaz kalibrasyonu yapmadan ana ekrana döner. Kalibrasyon i lemi sırasında [C] tu una basmak kalibrasyon i lemini iptal etmenizi sa lar. 06.10.09 Sayfa 10/14 AQUA METER 3.4.2. Serbest Klor Cihazının Kalibrasyonu Serbest klor kalibrasyonunda da önce yukarı a a ı tu ları ile kalibrasyon tipi seçilir. ZERO CAL: Sudaki klor miktarı sıfır oldu unda cihazın sıfır noktasını belirlemek için kullanılır. Giri tu una basılınca cihaz elektrot de erini okur ve sıfır noktası olarak kaydeder. DPD1 CAL: Suyun serbest klor miktarını ölçtükten sonra cihaza de eri girmenizi sa lar. Giri tu una basılınca DPD1 de erinin girilebilece i ekran gelir. Yukarı ve A a ı tu ları kullanılarak ekrandaki de erin istenilen de ere gelmesi sa lanır Tekrar Giri tu una basılarak kalibrasyon i lemi sonlandırılır. De er kaydetmeden çıkmak için [C] tu una basılır. 06.10.09 Sayfa 11/14 AQUA METER 3.4.3. letkenlik Cihazının Kalibrasyonu letkenlik kalibrasyonuna girince soldaki ekran görülür. letkenlik kalibrasyonu slope kalibrasyonu eklinde yapılır(Ham de erin ekranın solunda bulunan slope de eri ile çarpımı ve tekrar 1000’e bölünmesi ile yapılan i lem). letkenlik elektrotu tampon sıvıya daldırıldıktan sonra Yukarı ve A a ı tu ları ile Slope de eri de i tirilerek sa taraftaki de erin tampon sıvının de erine gelmesi sa lanır. Giri tu una basılarak de erin kaydedilmesi sa lanır [C] tu u basılırsa de er kaydedilmeden ana ekrana dönülür. 06.10.09 Sayfa 12/14 AQUA METER 3.5. Çıkı Kontrol Modları Cihaz çıkı kontrol modlarını ayarlayan iki adet parametre vardır. Cont Mode ve Output Mode Parametreleri. Parametre durumları ve açıklamaları a a ıda gösterilmi tir. Çıkı 1 Cont Output Mode Mode Çıkı 2 1 0 0 Okunan de er (Set + Offset) de erinin üzerine Okunan de er (Low_Alarm) de erinden çıkana kadar çıkı verir. Üzerine çıkınca keser, küçükse veya (High_Alarm) de erinden tekrar (Set – Offset) de erinin altına dü ene büyükse çıkı verir kadar bekler. 2 0 1 Okunan de er (Set – Offset) de erinin altına Okunan de er (Low_Alarm) de erinden dü ene kadar çıkı verir. Altına dü ünce keser, küçükse veya (High_Alarm) de erinden tekrar (Set + Offset) de erinin üzerine çıkana büyükse çıkı verir kadar bekler. 3 0 2 Okunan de er (Set + Offset) de erinin üzerine çıkana kadar çıkı verir. Üzerine çıkınca keser, tekrar (Set – Offset) de erinin altına dü ene kadar bekler. Okunan de er (High_Alarm – Offset) de erinin altına dü ene kadar çıkı verir. Altına dü ünce keser, tekrar (High_Alarm + Offset) de erinin üzerine çıkana kadar bekler. 4 1 0 Okunan de er (Set-Ratio_Diff) de erinin altındaysa sürekli çıkı verir. (Set) de erinin üzerine çıkana kadar oransal çıkı verir. (Set) de eri üzerinde çıkı vermez. Okunan de er (Low_Alarm) de erinden küçükse veya (High_Alarm) de erinden büyükse çıkı verir. 5 1 1 Okunan de er (Set+Ratio_Diff) de erinin üstündeyse sürekli çıkı verir. (Set) de erinin altında dü ene kadar oransal çıkı verir. (Set) de eri altında çıkı vermez. Okunan de er (Low_Alarm) de erinden küçükse veya (High_Alarm) de erinden büyükse çıkı verir Okunan de er (Set-Ratio_Diff) de erinin altındaysa sürekli çıkı verir. (Set) de erinin üzerine çıkana kadar oransal çıkı verir. (Set) de eri üzerinde çıkı vermez. Okunan de er (High_Alarm+Ratio_Diff) de erinin üstündeyse sürekli çıkı verir. (High_Alarm) de erinin altında dü ene kadar oransal çıkı verir. (High_Alarm) de erinin altında çıkı vermez. 1 6 2 3.6. Analog Çıkı Modları Durum Analog Type Açıklama 1 0 Analog Dif. noktası “0” kabul edilir ve Output Mode parametresine ba lı olarak hesaplana oran analog çıkı a yansıtılır. Bu durum oransal kontrollü dozaj pompalarının kontrolü için geli tirilmi tir. 2 1 Cihazın Minimum de eri %0 Maksimum de eri %100 kabul edilir ve okunan de er analog çıkı a yansıtılır. Cihazın transmitter olarak kullanılması için geli tirilmi tir. 06.10.09 Sayfa 13/14 AQUA METER 3.7. Seri Haberle me Cihaz RS485 seri haberle me portu sayesinde bilgisayar, yazıcı ve Antech Bilgilendirme Panelleri ile haberle ebilmektedir. Durum Ba lantı Comm Mode Dev Addr. Log Interv. Açıklama 1 Yazıcı 1 0-30 0-30 Yazıcı ba lantısı yapıldı ında cihaz master moda olmalı, 0-30 arası bir adres belirlenmeli ve 0-30 dk. arasında yazıcıya bilgi gönderme süresi belirlenmelidir. 2 Info Panel 0 0-30 - Info Panel ba lantısında cihaz slave olmalı 0-30 arası bir adres belirlenmelidir. 3 Bilgisayar 0 0-30 - Bilgisayar ba lantısında cihaz slave olmalı 0-30 arası bir adres belirlenmelidir. 3.8. ifre Kullanımı Cihazın yetkili olmayan ki iler haricinde kullanımı engellemek üzere ifre ile korunabilmektedir. ifre korumanın aktif olması için “09-Pass.Enable” parametresinin de erinin 1 yapılması gerekmektedir. “21-Password” parametresi ise ifreyi de i tirmek için kullanılır. E er ifre unutulursa ana ekranda iken sırasıyla A a ı tu una 30 saniyeden daha uzun bir süre basılı tutulur. Bu “09-Pass.Enable” parametresinin “0” olmasını sa lar. Ekranda “Password Disabled” Mesajı Görülür. 4. Servis Cihazın, kapa ı kapalı tutuldukça hiç bir bakım gerektirmez. 5. Garanti ve Standartlar Cihazınız, yasal hükümlülükler çerçevesinde malzeme ve üretim hatalarından kaynaklanan hasarlar için 2 yıl garantilidir. Normal yıpranma, a ırı yükleme veya usulüne aykırı kullanmadan kaynaklanan hasarlar garanti kapsamında de ildir. Malzeme veya üretim hatalarından kaynaklanan hasarlar, hatalı parça veya cihazın kendisinin verilmesi veya onarımı yolu ile telafi edilir. Garantiye ili kin talepler ancak cihaz sökülmeden teslimatçı ya da yetkili servise getirildi i takdirde kabul edilir. 6. Teknik Çizimler 06.10.09 Sayfa 14/14