Universal control module for motorized devices

Transkript

Universal control module for motorized devices
Universal control module for motorized devices
Ref: MOD-0105-N
The MOD-0105-N is a universal module for motorized devices,
blinds, awnings, curtains, doors, etc..
Allows, with vivimat® BUS , the local or remote control of a motorized devices, ensuring a reliable use of the motor in both cases.
One of its most common uses is to combine the management of
various motorized devices, and to control them centrally in a safe
way, while the direct access from the individual push buttons of each
device is still operational.
Technical characteristics
Number of motorized devices
1
Power supply
230VAC 50Hz
Consumption
<0,5W
Output type
2 Relies NO de 5A/250VAC connected to phase
Maximum engine power
500W
Overcurrent and overvoltage protection
Via electronic fuses and varistors
Temperature range
-10ºC / 40ºC
Compatible with
vivimat® III
Communication with the vivimat® system
LED status indication
Through the vivimat® BUS
ID configuration in the BUS
via switch
Panel installation
DIN rail mounting
Requires adaptation kit ADP-0010
(NOT INCLUDED)
Universal control module for motorized devices
Dimensions
-
+
42 mm
70 mm
70 mm
44 mm
25 mm
25 mm
70 mm
35 mm
* MOD-0105 + adaptation part ADP-0010 for DIN rail. (NOT INCLUDED)
Connections
vivimat® BUS
Switches
Manual push down buttons
+
Manual push up buttons
-
Remote push down buttons
+
-
Remote push up buttons
Neutral motor N - Output
Output motor down
Output motor up
Phase
F
N
TT-230 Vac
- Wiring: All wires of 0,22mm2
Neuter
Earthing
Universal control module for motorized devices
Configuration
Via the switches the MOD-0105-N can define its module address in the vivimat® BUS . vivimat® III can have up
to 50 motorized devices control modules. Select the address of each module as indicated in the
configuration made with vivimat® Project. The addresses of the modules are consecutively
assigned by vivimat® Project (There must not be 2 modules of the same type with the same address).
ADDRESS 1
ADDRESS 2
ON
ADDRESS 3
ON
1
2
3
4
5
6
1
ADDRESS 10
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
3
4
5
6
2
3
4
5
1
2
3
4
5
6
1
2
3
4
5
3
4
5
1
2
3
4
5
2
3
4
5
2
3
4
5
6
2
3
4
5
2
3
4
5
1
2
3
4
5
2
3
4
5
1
6
1
2
3
4
5
6
2
3
4
5
6
2
3
4
5
2
3
4
5
1
6
2
3
4
5
4
5
6
2
3
4
5
2
3
4
5
6
1
2
3
4
5
2
3
4
5
6
ADDRESS 49
3
4
5
6
2
3
4
5
6
2
3
4
5
1
2
3
4
5
6
2
3
4
5
1
5
6
2
3
4
5
6
2
3
4
5
1
2
3
4
5
6
2
3
4
5
2
3
4
5
6
1
4
5
6
2
3
4
5
6
2
3
4
5
6
ADDRESS 36
ON
1
2
3
4
5
6
1
ADDRESS 44
6
3
ADDRESS 27
2
3
4
5
6
ADDRESS 45
ON
1
1
ADDRESS 35
6
2
ADDRESS 18
ON
1
1
ON
ADDRESS 43
6
4
ADDRESS 26
ON
1
3
ON
ADDRESS 34
6
2
ADDRESS 17
ON
1
1
ON
ADDRESS 42
6
5
ADDRESS 25
ON
2
1
ADDRESS 33
ADDRESS 41
1
4
ON
1
6
3
ON
ADDRESS 24
6
2
ON
ADDRESS 16
ON
1
1
ON
ADDRESS 32
6
3
ON
1
6
2
ADDRESS 9
ON
ADDRESS 15
ON
1
1
ON
ADDRESS 40
6
5
ADDRESS 23
ON
1
2
3
4
5
6
1
2
3
4
5
6
ADDRESS 50
ON
1
4
ON
1
6
3
ADDRESS 8
ON
ADDRESS 14
ADDRESS 31
6
2
ON
ADDRESS 48
6
1
ADDRESS 22
ON
1
6
ON
ADDRESS 47
6
5
ON
ADDRESS 39
ON
4
ON
1
6
3
ADDRESS 7
ON
ADDRESS 13
ON
ADDRESS 46
ON
1
1
6
2
ON
ADDRESS 38
6
1
ADDRESS 30
ON
2
6
ON
ADDRESS 37
ON
1
1
ADDRESS 29
6
5
ADDRESS 21
ON
1
4
ON
ADDRESS 28
ON
3
ON
ADDRESS 20
ON
2
2
ON
ADDRESS 19
ON
1
1
ADDRESS 6
ON
ADDRESS 12
ON
ADDRESS 5
ON
ADDRESS 11
ON
ADDRESS 4
ON
ON
1
2
3
4
5
6
1
2
3
4
5
6
The modules MOD-0105-N belonging to a vivimat® III system must be registered in the configuration of the installation
which is implemented by vivimat® Project, assigning an ID number to the module and specifying which motorized
devices, the module is going to control.
Universal control module for motorized devices
Functioning
LOCAL CONTROL :
Local control is carried out by on or more buttons connected in parallel (see connections).
-A short key press (less than 0,5 sec.) will move totally up or down (motorized device).
depending on the push button you have press (up or down)
- If the device is moving, a short pressing in the opposite direction will stop the device.
- A long key press on the up or down buttons it will move up or down the device depending on the button you
have pressed: In the panel you will just see the positions 0 - 20 - 40 - 60 - 80 - 100%
REMOTE CONTROL:
The control is carried out by the vivimat® home automation system BUS.
It is possible to activate the following functions remotely:
- Move up or down totally the motorized device.
- Move up or down the motorized device to a certain position. 0 - 20 - 40 - 60 - 80 - 100%
- Know the status of the motorized device: 0 - 20 - 40 - 60 - 80 - 100%
- Configure the module.
*SECURITY: The module prioritizes local orders to remote orders. If the module is executing
an “up” or “down” order in the remote mode, the key press of any local key will stop the motorized devices.
LED STATUS INDICATION:
1- Green blinking: Module operative .
2- Red blinking: Module in communication.
3- Red or NOT illuminated: Problems with the module.
Universal control module for motorized devices
Installation recommendations
- Installation corresponding to a > 100 x 100mm box: The 100 x 100mm box is embedded in the wall of the housing.
With 2 screws (NOT INCLUDED) we fix the MOD-0105-N to the box (1).
1
- DIN rail installation: For the DIN rail installation, you require the adaptation kit ADP-0010 (NOT INCLUDED),
consisting of 2 pieces, which has to be inserted into the rear of the module (1). Once the pieces are inserted, we fit
the module into the DIN rail (2).
1
Adaptation part x 2
3
FT-MOD-0105-N_11/01/10-ENG
Product manufactured by: Dinitel 2000 S.A. - Avda. Otaola 20 20600 Eibar ( Guipúzcoa ) Spaint
T. +34 902 111 220 / +34 943 820 458 F. +34 902 124 779
www.domotica-vivimat.com