seri haberleşmeli
Transkript
seri haberleşmeli
SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU HİDROLİK / MEKANİK ASANSÖRLER Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-1- İçindekiler Bölüm 1. Elektronik parçaların montajı 1.1 Kumanda panosu kartları………………………………………………………………………………… 2 1.1.1 Anakart, SL-MAIN….…………………………………………………………………………………………... 2 1.1.2 Seviyeleme kartı GL-2lev……………………………………………………………………………………… 5 1.1.3 Acil indirme kartı, GL4………….……………………………………………………………………………… 6 1.1.4 Besleme kartı, SL-3B……..……………………………………………………………………………………. 7 1.2 Seri veriyolu haberleşme sistemi……………………………………………………………………….. 8 1.2.1 Revizyon kutusu kartı, SL-DIS..………………………………………………………………………………. 8 1.2.2 Kabin butonyeri kartı, SL-COP………...………………………………………………………………………. 10 1.2.3 Veriyolu modülü, SL-IO….…………………………………………………………………………………… 10 Bölüm 2. Kuyu kopyalama 2.1 Katta durdurucu tüp manyetikler (CAA-CAB) ve ön nihai şalterler (EM, ED)……………………….. 11 2.1.1 Mıknatısların yerleştirilmesi…………………………………………………………………………………….. 11 2.1.2 Ön nihai şalterler………………………………………………………………………………………………. 12 2.2 Kat seviyesi sınır tüp manyetikleri (CAZA, CAZB)……………………………………………………… 12 2.2.1 Mıknatısların yerleştirilmesi ………………………………………………………………………………….. 12 2.3 Hidrolik asansörde mıknatısların yerleştirilmesi………………………………………………………… 13 2.4 Mekanik asansörde mıknatısların yerleştirilmesi……………………………………………………….. 14 2.5 Seviyeleme işlemi….………………………………………………………………………………………. 15 Bölüm 3. Hazır tesisat montajı 3.1 Şebeke beslemesi ve motor bağlantıları…...……………………………………………………………. 16 3.2 Bağlantı soketleri…………………………………………………………………………………………… 17 3.3 Kuyu emniyet devresi ve ön nihai şalterlerin bağlantıları - SC8……………………………………… 18 3.3.1 Sınır ve ön nihai şalterler….……………………………………….…………………………………………… 19 3.3.1.1 Hidrolik asansör - 1:1 askı, HA, HAS, HAD ………….………………………………………………19 3.3.1.2 Hidrolik asansör - 1:2 askı tek piston, HAI …………………………………………………………. 20 3.3.1.3 Hidrolik asansör - 1:2 askı çift piston, HADI …………….…………………………………………. 21 3.3.1.4 Mekanik asansör…………………………………………………………………………………. 22 3.3.2 Hız regülatörü ve halat gevşeme kontakları…………………………..……………………………………... 23 3.3.2.1 Hidrolik asansör, HADI……………………………………………………………………………. 23 3.3.2.2 Mekanik asansör………………………………………………..….……………………………. 24 3.3.3 Kat kapıları emniyet devresi………………………………………….………………………………………. 25 3.3.3.1 Yarı otomatik kapılar ……………………………………………………………..………………. 25 3.3.3.2 Otomatik kapılar …………………..…………………………………………………………….. 26 3.4 Hidrolik ünite bağlantıları - KC10……………………………………………………………………….. 27 3.4.1 BLAIN valf bloğu…………………………………………………………………………………………………. 27 3.4.2 BUCHER valf bloğu ……………………………………………..……………………………………………… 28 3.5 Kuyu dibi bağlantıları – PIT STOP……………………………………………………………………….. 29 3.6 Kat butonları………………………………………………………………………………………………… 31 3.7 Kabin kapıları………………………………………………………………………………………………. 32 3.7.1 Otomatik kabin kapısı, KRAMER tipi……………………………………………………………….……… 32 3.7.2 Otomatik kabin kapısı, VVVF tipi……………………………………………………………………………... 33 3.8 Kabin bağlantıları…………………………………………………………………………………………. 34 3.9 Kabin butonyeri iç bağlantılar………………………………………………………………………….…. 35 Bölüm 4. Parametreler 4.1 Parametre programlama……………………………………………………………………………….….. 36 4.2 Ek özellikler………..………………………………………………………………………………………...36 4.3 Parametre analizi….……….………………………………………………………………………….…… 37 4.3.1 ‘Parametre programlama’ kategorisi………...……………………………………………….……………….. 37 4.3.1.1 Genel Zaman Ayarı ………………………………………………………………………………….. 37 4.3.1.2 Kat Bilgisi…………………………………………………………………………………………….. 37 4.3.1.3 Kapı Bilgisi……………………… …………………………………………………………………… 38 4.3.1.4 Seyir Bilgisi ……………………………………………………………………………………… 39 4.3.1.5 Yangın İhbar Bilgisi ………..………………………………………………………………………..39 4.3.1.6 Kayıt Sinyali Bilgisi …….………………………………………………………………………….. 40 4.3.1.7 Veriyolu Bilgisi…………………………………………………………………………………. 40 Bölüm 5. Hatalar 5.1 Hata kontrolü………………………………………………………………………………………………. 41 5.2 Hata listesi………………………………………………………………………………………………….. 42 KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-2- Bölüm 1. Elektronik parçaların montajı Bu bölümde Seri haberleşmeli kumanda panosu ve hazır tesisatının montajı anlatılmıştır. 1.1 Kumanda panosu kartları 1.1.1. Anakart, SL-MAIN SL-MAIN seri haberleşmeli kumanda panosunun anakartıdır. Kart üzerinde çalışma programını içeren mikroişlemci ve parametre hafızası için EEPROM bulunmaktadır. Bu nedenle veri işleme, parametre programlama ve hata kontrolü işlemleri SL-MAIN tarafından yürütülmektedir. 2 satırlı LCD ekran ve kontrol butonları parametre programlama ve hata kontrolü için kullanılmaktadır. Resim 1.1: Anakart, SL-MAIN No 1 2 KILAVUZ: SERİ HAB. Kodu MC1 MC2 Sinyal +24V +24V +24V 0V 0V 0V IOSP1 IOSP2 IOSP3 IOSP4 Giriş/Çıkış Açıklama Besleme voltajı G/Ç G/Ç G/Ç G/Ç Serbest programlanabilir girişler / çıkışlar http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU No Kodu 3 MC3 4 MC4 5 MC5 6 MC6 7 MC7 Sinyal Giriş/Çıkış +CAM 0V +RLU Ç Açıklama Pompa Ç Kabin aydınlatması 0V +CL Ç Asansör kullanımda 0V +O3 Ç Servis dışı 0V STH G Motor termistörü MTH G Yağ termistörü (hidrolik) / Acil indirme komutu (mekanik) CP 8 MC8 Termistörler için ortak uç CAA G Katta durdurucu üst tüp manyetik CAB G Katta durdurucu alt tüp manyetik ED G Alt ön nihai şalter EM G 0V 0V Üst ön nihai şalter SWC Ön nihai şalterler için ortak uç 1B 9 MC9 G Emniyet devresi geri besleme – 1. nokta 6 G Emniyet devresi geri besleme – 2. nokta 8A G Emniyet devresi geri besleme – 3. nokta 8 G Emniyet devresi geri besleme – 4. nokta 10 G Emniyet devresi sonu FLI G Tam yük 0V 10 MC10 0V O3I G Servis dışı VVVF G VVVF hatası Yangın emniyeti FIR G SUI G Aşırı yük FPR G Kontaktör durumu MAN G CMan 11 MC11 Sayfa-3- Kumanda panosunun revizyon modu Kumanda panosu revizyon butonları için ortak uç MUp G Kumanda panosu revizyon YUKARI butonu MDwn G Kumanda panosu revizyon AŞAĞI butonu SH8 Ç Seviyeleme işlemi için emniyet devresi kısa devre komutu ZONE G Kabin kat seviyesinde F+24V 12 13 MC12 MC13 3PFI 0V H-BUS-A 14 MC14 H-BUS-B Seri haberleşme veriyolu L-BUS-A L-BUS-B 15 MC15 IF-A IF-B L-C 16 17 TB1 TB2 Kontaktörlerin aktivasyon çıkışları için voltaj L Ç Hareket kontaktörü Y D C-V Ç Ç D Ç C Ç B Ç A Ç Yıldız kontaktör Üçgen kontaktör Hız çıkışları için voltaj Aşağı yönde düşük hız (Hidrolik) / Düşük hız kontaktörü (Mekanik çift hızlı) / Yüksek hız kontaktörü (Mekanik tek hızlı) Aşağı yönde yüksek hız (Hidrolik) / Yüksek hız kontaktörü (Mekanik çift hızlı) / VVVF (VVVF Mekanik) Yukarı yönde yüksek hız (Hidrolik) / Aşağı yön kontaktörü (Mekanik) / VVVF (VVVF Mekanik) Yukarı yönde düşük hız (Hidrolik) / Yukarı yön kontaktörü (Mekanik) / VVVF (VVVF Mekanik) Tablo 1.1: SL-MAIN bağlantı uçları KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-4- Açıklama Röle 24VDC Η3 Η4 Η5 Η6 Hidrolik Aşağı yönde düşük hız Aşağı yönde yüksek hız Yukarı yönde yüksek hız Yukarı yönde düşük hız Tek hızlı mekanik Çift hızlı mekanik VVVF mekanik Yüksek hız Düşük hız --- Yüksek hız Aşağı yön Aşağı yön Yukarı yön Yukarı yön --- VVVF Η1 Motor çalıştırma --- --- --- Η2 Yıldız bağlantı --- --- --- Tablo 1.2: SL-MAIN röleleri KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-5- 1.1.2 Seviyeleme kartı, GL-2LEV GL-2LEV kartı kapılar açıkken seviyeleme işlemini yürütmek için seri haberleşmeli kumanda panosunda yer almaktadır. Kartın ana işlevi kapı emniyet devresini kısa devre yaparak aşağıda açıklanan işlemleri gerçekleştirmektir. Aşağıdaki tablo kartın bağlantılarını açıklamaktadır. Resim 1.2: Seviyeleme kartı GL-2LEV Soket / Konnektör TB1 TB2 MC1 MC2 MC3 Açıklama Kat seviyesi sınır tüp manyetikleri (CAZA, CAZB) Kapı emniyet devresi kısa devre SL-MAIN’e kat seviye bilgisi, SL-MAIN’den seviyele işlemi hakkında bilgi Kart beslemesi Acil indirme kartına (GL4) kat seviyesi hakkında bilgi Tablo 1.3: GL-2LEV bağlantı uçları KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-6- 1.1.3 Acil indirme kartı, GL-4 GL-4 kartı hidrolik asansörlerde otomatik kurtarma fonksiyonu için kullanılır. Asansör normal çalışma durumundayken 110VAC ile emniyet devresini çalıştırır ve kontrol eder aynı zamanda akü şarj devresiyle acil durum aküsünü (12V, 2Ah) şarj eder. Elektrik kesildiğinde pano otomatik kurtarma prosedürünü başlatır. GL-4 kartı emniyet devresini 12VDC ile çalıştırır ve devrenin sürekliliğini ve acil indirme bobininin 12VDC ile beslendiğini kontrol eder. Kabindeki siren ve acil aydınlatma da bu kart ile çalışır. Yarı otomatik kapılarda kurtarma prosedürü kapı kilitleri açıldığında durdurulur. Bu durum kabinin kat seviyesinin biraz yukarısında durmasına yol açabilir. Bu nedenle kart üzerinde kurtarmanın süresini uzatan bir potansiyometre vardır. Böylece kabinin net kat seviyesine ulaşmasını sağlanır. Kart bağlantıları aşağıdaki tabloda açıklanmıştır. Resim 1.3: Acil indirme kartı GL-4 Klemens / Konnektör ΤΒ1 ΤΒ2 ΤΒ3 ΤΒ4 MC1 MC2 MC3 Açıklama GL4 besleme voltajı (15V AC) Alarm sireni ve acil aydınlatma için besleme 13,8 VDC Emniyet devresi bağlantıları Acil indirme bobini bağlantıları GL2 kartından kat seviyesi girişi Akü izleme MC2 konnektörüne bağlanır – GL2 kartı Tablo 1.4: GL-4 bağlantı uçları KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-7- 1.1.4 Besleme kartı SL-3B The SL-3B kartı anakartı 24VDC ile besler. Kart üzerinde ayrıca akü şarj devresi ve redresör bulunur. Redresör asansörün özelliklerine göre valf bloğu veya yarı otomatik kapılarda lirpomp beslemesinde kullanılabilir. Resim 1.4: Besleme kartı, SL-3B Klemens / Konnektör TB1 TB2 TB3 MC1 MC2 Açıklama Giriş voltajı 28VAC - Çıkış voltajı 24VDC Alarm sireni ve acil aydınlatma için (GL-4 kullanılmadığında) Giriş voltajı 15VAC- Çıkış voltajı 13,8VDC Redresör bağlantıları Anakarta voltaj çıkışı MC2 konnektörüne bağlanır – GL2 kartı (GL-4 kullanılmadığında) Tablo 1.5: SL-3B bağlantı uçları KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-8- 1.2 Seri veriyolu haberleşme sistemi Kumanda panosu; kabin ve kuyu ile olan çift yönlü iletişiminde bir seri veriyolu kullanır. Bu nedenle tüm veriler direkt bağlantılar vasıtasıyla anakartta son bulmadan seri veriyolu ile taşınırlar. Seri veriyolundan kastedilen iki (2) besleme hattı (24VDC) ve iki (2) veri transfer hattıdır. Veri transferi için gerekli kablo sayısının önemli ölçüde azalarak sonuç olarak hızlı ve kolay montaj sağladığı açıktır. Aynı zamanda oluşabilecek muhtemel hatalar bağlantı sayısı azalararak en aza indirilmiştir. Kuyudaki haberleşme veriyolu BUS hattındaki dört (4) kablo sağlanır. Kablolar paralel ve seri sinyaller arasında dönüştürücü görevi gören SL IO kartlarında son bulur. Kabinin haberleşme veriyolu FC1 yassı kablosunun revizyon kutusundaki SL-DIS’te son bulan dört (4) kablosu ile sağlanır. SL-DIS vasıtasıyla seri veriyolu uzatılarak SL-COP kabin butonyeri kartına bağlanır. 1.2.1 Revizyon kutusu kartı, SL-DIS SL-DIS kabin revizyon kutusunda yer alır. Kart bağlantıları aşağıdaki tabloda anlatılmıştır. Resim 1.5: Revizyon kutusu kartı SL-DIS No Kodu Sinyal Açıklama +BAT 1 TB1 Telefon hattı TEL1 TEL2 +24V_IN 2 TB2 0V_IN H_B_A Seri haberleşme veriyolu H_B_B 3 TB3 CAA Katta durdurucu üst tüp manyetik (çıkış) CAB Katta durdurucu alt tüp manyetik (çıkış) CAZA Kat seviye sınır tüp manyetiği A (çıkış) CAZB Kat seviye sınır tüp manyetiği B (çıkış) CAZ+ KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU No 4 Kodu TB4 Sinyal Açıklama MCAZ+ MCAZA Kat seviye sınır tüp manyetiği A (giriş) MCAZB MCAZ- 5 6 7 TB5 TB6 TB7 Sayfa-9- Kat seviye sınır tüp manyetiği B (giriş) MCAA Katta durdurucu üst tüp manyetik (giriş) MCAB Katta durdurucu alt tüp manyetik (giriş) CM Ortak uç ED Alt ön nihai şalter EM Üst ön nihai şalter 0V 0V INS Kabinin revizyon modu INSUP Kabin revizyonu YUKARI butonu INSDOWN Kabin revizyonu AŞAĞI butonu CINS Ortak uç SPI1 8 TB8 SPI2 SPI3 Programlanabilir girişler 0V 9 10 11 TB9 TB10 TB11 +24V +24V 0V 0V SUI Aşırı yük girişi (kabine monte edilmiş yük kontrol aygıtı) FLI Tam yük girişi (kabine monte edilmiş yük kontrol aygıtı) DC Kapı kapama komutu DO Kapı açma komutu C-D Kapı komutları için besleme DCL1 Kapı kapama sınır anahtarı DOL1 Kapı açma sınır anahtarı 0V 0V CS1 Fotosel 0V 0V SPO1 12 TB12 SPO2 SPO3 Programlanabilir çıkışlar +24V 13 TB13 14 TB14 15 TB15 16 MC1 TEL1 Telefon hattı TEL2 FAN Fan beslemesi (çıkış) FAN NF Fan beslemesi (giriş) LF SL-DIS – SL-COP ara bağlantısı Tablo 1.6: SL-DIS bağlantıları KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-10- 1.2.2 Kabin butonyeri kartı, SL-COP SL-COP tüm kabin butonyeri bağlantılarının yapıldığı karttır. SL-DIS kartı ile ara bağlantısı 16pin konektörlü MC1 kablosu ile sağlanır. Resim 1.6: SL-COP kabin butonyeri kartı 1.2.3 Veriyolu modülü, SL-IO SL-IO veriyolu modülleri çoğunlukla kuyuya monte edilir ve seri haberleşme veriyoluna bağlanır. Genellikle kat butonyerleri (LOP) ile kumanda panosu arasındaki iletişimde kullanılırlar. Kart panodan aldığı tüm seri sinyalleri paralele, butonlardan aldığı paralel sinyalleri de seriye dönüştürür. Klemenste seri veriyolu TB1’e, kat butonlarının bağlantıları TB2 ve TB3’e bağlanır. Resim 1.7: Veriyolu modülü, SL-IO KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-11- Bölüm 2. Kuyu kopyalama Anakarta kabinin kuyudaki konumu, katların konumu ve yavaşlama noktaları hakkındaki bilgiler gereklidir. Bu bilgiler tüp manyetikler ve nihai şalterler vasıtasıyla sağlanır. Tüp manyetikler kullanımına göre iki kategoriye ayrılır: a) katta durdurucu tüp manyetikler (CAA, CAB), b) kat seviyesi sınır tüp manyetikleri (CAZA, CAZB) 2.1 Katta durdurucu tüp manyetikler (CAA-CAB) ve ön nihai şalterler (EM, ED) İki katta durdurucu tüp manyetik kullanılır. Bunlar kabin karkasına monte edilen özel alüminyum tutuculara kılavuz rayın aynı tarafını görecek şekilde dikey olarak yerleştirilir. Üstteki tüp manyetiğe CAA, alttakine CAB denir. Bunlar anakarta kabinin kuyudaki konumu ve yavaşlama noktaları hakkında bilgi sağlar. CAA, CAB Şekil 3.1’de görüldüğü gibi rayın bir tarafına yerleştirilmiş 10cm lik mıknatıs çifti tarafından etkin hale gelir. Mıknatis çifti tüp manyetiklerin etkinleşmesini kesinleştirmek için kullanılır. Toplam mıknatıs adedi durak adedine bağlıdır: Mıknatıs adedi = [(durak adedi-1) x 8] + 4. 2.1.1 Mıknatısların yerleştirilmesi Mıknatıslar çalışmalarına göre iki kategoriye ayrılırlar: a) Kat ve seviyeleme mıknatısları b) Hız değiştirme mıknatısları a) Kat ve seviyeleme mıknatısları 3cm 10cm Kabin zemin kat net seviyesinde durdurulur. Bir mıknatıs üst tüp manyetiğin (CAA) 3-5 cm üzerine, diğer mıknatıs da alt tüp manyetiğin (CAB) 3-5 cm altına yerleştirilmelidir. Bu kural montajdaki her kat için tekrarlanır. Belirtilen mesafe asansörün yavaş hızdaki hareketinin eylemsizliğine bağlıdır. Bu nedenle en iyi seviyelemeyi başarmak için her asansörün kendi mesafesi olmalıdır. Kabin katta durduğunda iki tüp manyetik kat ve seviyeleme mıknatıslarının arasında kalmalıdır. 5cm (MIN) 10cm 3cm level Şekil 3.1: Katta durdurucu tüp manyetikler b) Hız değiştirme mıknatısları Başlangıçta frenleme mesafesi hesaplanmalıdır. Hidrolik asansörde bu mesafe asansörün hızıyla doğrudan ilişkilidir. Örneğin asansörün hızı u=0.6m/sn ise mesafe S=60cm olacaktır. Üst tüp manyetiğin üzerine mıknatıs yerleştirirken manyetik ile hız değiştirme mıknatısının üst kısmı arasındaki mesafe 60cm olmalıdır. İkinci bir mıknatıs alt tüp manyetiğin altına manyetik ile hız değiştirme mıknatısının alt kısmı arasındaki mesafe 60cm olacak şekilde yerleştirilmelidir. Bu kural montajdaki her kat için tekrarlanmalıdır. En üst katta üst tüp manyetik üzerine ve en alt katta alt tüp manyetik altına hız değiştirme mıknatısı yerleştirilmesine gerek olmadığı açıktır. Mekanik asansörde frenleme mesafesi asansör hızının 1,2 katına eşittir. Örneğin asansörün hızı u=1.0m/sn ise mesafe S=120cm olacaktır. Üst tüp manyetiğin üzerine mıknatıs yerleştirirken manyetik ile hız değiştirme mıknatısının üst kısmı arasındaki mesafe 120cm olmalıdır. İkinci bir mıknatıs alt tüp manyetiğin altına manyetik ile hız değiştirme mıknatısının alt kısmı arasındaki mesafe 120cm olacak şekilde yerleştirilmelidir. Bu kural montajdaki her kat için tekrarlanmalıdır. En üst katta üst tüp manyetik üzerine ve en alt katta alt tüp manyetik altına hız değiştirme mıknatısı yerleştirilmesine gerek olmadığı açıktır. KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-12- 2.1.2 Ön nihai şalterler En üst ve en alt katta hız değiştirme mıknatıslarından önce üst ön nihai şalter (EM) ve alt ön nihai şalter (ED) olmak üzere iki adet nihai şalter bulunur. Bunlar kabin karkasına monte edilen kama ile etkin hale gelir ve kontak açarak kabinin kabinin yavaş hızda hareketini kesinleştirir. EM ve ED’nin etkinleşme durumuna göre pano kabinin en üst veya en alt kata yaklaştığını algılar. 2.2 Kat seviyesi sınır tüp manyetikleri (CAZA, CAZB) Bu iki tüp manyetik hidrolik asansörlerde kullanılır ve seviyeleme ve otomatik acil indirme işlemlerinde gereklidirler. Kabin karkasına monte edilmiş özel alüminyum tutuculara rayın farklı taraflarını görecek şekilde yatay olarak yerleştirilir (Katta durdurucu tüp manyetikler ile kat seviyesi sınır tüp manyetiklerinin farklı kılavuzları rayı görmeleri gerektiği açıktır). CAZA kat seviyesi sınır tüp manyetiği bir değişken kontak taşır, CAZB ise NO (Normalde açık) kontak taşır ve ikisi de kabin revizyon kutusuna bağlıdır. Bunlar panoya normal ve acil indirme çalışmasında kabinin kat seviyesine girdiğini bildirir. 2.2.1 Mıknatısların yerleştirilmesi Tüp manyetikler kılavuz raya yerleştirilen 20cm’lik mıknatıs çiftiyle etkin hale gelir. Yerleştirilecek mıknatıs adedi toplam durak adedine bağlıdır. Mıknatıs adedi = durak adedi x 4. Mıknatısları yerleştirmek için kabin en alt kata net kat seviyesine getirilmelidir. Kılavuz rayın iki tarafına bir mıknatısı tüp manyetikleri mıknatısın ortasına bakacak şekilde yerleştirin. Bu kural her katta tekrarlanmalıdır. 10cm 10cm 10cm 10cm LEVEL 20cm Şekil 3.2: Kat seviyesi sınır tüp manyetikleri Kat seviyesi tüp manyetikleri kabinin hareketi esnasında mıknatısları aynı anda görmelidir. Tüp manyetikler ve katlardaki mıknatıslar buna göre hizalanmalıdır. KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-13- 2.3 Hidrolik asansörde mıknatısların yerleştirilmesi Bu örnekte : • Durak adedi = 4 • Kabin hızı = 0.6m/sn • Frenleme mesafesi = [Kabin hızı]x1 = 0.6 x 1 = 60cm SC8:82(1B) Upper limit switch (TOS) Guide rails SC8:85 (EM) 5cm Upper pre-final switch (ÅÌ ) 10cm Operational magnetic switches SC8:82(1B) 60cm Zone magnetic switches 3cm 11cm Level 3 12cm Lift stopped at the upper level 20cm SC8:87 (0V) 11cm Level 2 60cm 60cm 3cm 11cm Level 1 Lift stopped at an indermediate level 60cm Lift stopped at the lower level 12cm SC8:86 (ED) Lower pre-final switch (ÅD) SC8:87 (0V) 3cm 11cm Level 0 Şekil 3.3: Hidrolik asansörde mıknatısların yerleşimi örneği KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-14- 2.4 Mekanik asansörde mıknatısların yerleştirilmesi Bu örnekte : • Durak adedi = 4 • Kabin hızı = 1m/sn • Frenleme mesafesi = [Kabin hızı]x1,2 = 1 x 1,2 = 120cm SC8:82(1B) Upper limit switch (TOS) Guide rail SC8:85 (EM) 5cm Upper pre-final switch (ÅÌ ) 10cm Operational magnetic switches SC8:82(1B) 120cm 3cm 11cm Level 3 12cm Lift stopped at the upper level SC8:87 (0V) 120cm 11cm Level 2 Lift stopped at an intermediate level 120cm 3cm 11cm Level 1 120cm Lift stopped at the lower level 12cm SC8:86 (ED) Lower pre-final switch (ÅD) SC8:87 (0V) 3cm 11cm Level 0 SC8:82(1B) Lower limit switch (BOS) SC8:82(1B) Şekil 3.4: Mekanik asansörde mıknatısların yerleşimi örneği KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-15- 2.5 Seviyeleme işlemi Hidrolik asansörlerde kabin yükleme ve boşaltmadan dolayı net kat seviyesinden çıkabilir. Bu durumlarda pano kabini doğru kat seviyesine getirmek için seviyeleme işlemini gerçekleştirir. Tüp manyetiklerin asansör durduğunda seviyeleme işleminin gerekli olup olmadığının belirlenmesi için kabinin konumu hakkında panoyu bilgilendirir. Aşağıdaki tablo tüp manyetiklerin konumuna göre seviyeleme işleminin gerçekleşmesi durumlarını gösterir. Kat seviyesi sınır tüp manyetikleri CAZA, CAZB Katta durdurucu üst tüp manyetik CAA Katta durdurucu alt tüp manyetik CAB Kabinin konumu Seviyeleme Etkin Etkin değil Etkin değil Kat seviyesinde Hayır Etkin Etkin Etkin değil Net kat seviyesinin üstünde Evet, Aşağı Etkin Etkin değil Etkin Net kat seviyesinin altında CAZA Evet, Yukarı CAZB Şekil 3.5: Kabin kabul edilebilir kat seviyesindeyken tüp manyetiklerin konumu Şekil 3.6: Kabin kabul edilebilir kat seviyesinin üzerindeyken tüp manyetiklerin konumu Seviyeleme işlemi aşağıda tarif edilmiştir: • Kabin bir katta kapılar açık durmaktadır • Kat seviyesi sınır tüp manyetikleri – CAZA, CAZB – etkintir. GL-2LEV kartı kabinin kat seviyesinde olduğu bilgisini anakarta iletir. • SL-MAIN kartı katta durdurucu tüp manyetiklerin (CAA, CAB) durumunu kontrol eder. • İkisi de etkin değilse pano normal çalışmasını sürdürür • İkisinden biri etkin ise anakart kapı emniyet devrelerini (emniyet devresi 6-10) kısa devre yapması için GL2LEV kartını bilgilendirir. • GL-2LEV kartı kapı emniyet devrelerini kısa devre yaptıktan sonra emniyet devresi sürekli ise pano kabini doğru konumuna getirmek için yukarı veya aşağı hareket başlatır. • İki katta durdurucu tüp manyetik etkin olmadığı anda pano hareketi durdurur ve kapı emniyet devrelerindeki kısa devrenin kaldırılması için GL-2LEV kartını bilgilendirir. KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-16- Bölüm 3. Hazır tesisat montajı 3.1 Şebeke beslemesi ve motor bağlantıları Aşağıdaki şekillerde panoda şebeke anahtarı kullanıldığı veya kullanılmadığı durumlarda şebeke beslemesi ve motor bağlantıları gösterilmektedir. 3phase motor Single phase motor L N L' 3phase motor • Direct Coupling - Hydraulic lift • VVVF or 1speed - Traction lift N' PE N Mains supply 1~ 230V AC L1 L2 L3 U1 V1 W1 • Õ-Ä Coupling - Hydraulic lift • 2speeds - Traction lift PE N N L2 L3 U1 V1 W1 W2 V2 PE U2 Mains supply 3~ 400V AC Mains supply 3~ 400V AC L L1 PE U M 1~ V W PE U1 V1 W1 M 3~ M 3~ W2 V2 U2 Şekil 3.1: Şebeke beslemesi ve motor bağlantısı (şebeke anahtarı olmayan pano) • Õ-Ä Coupling - Hydraulic lift • 2speeds - Traction lift • Direct Coupling - Hydraulic lift • VVVF or 1speed - Traction lift I ON I ON N OFF O L' L 3phase motor 3phase motor Single phase motor N' I ON N OFF O PE N U1 N Mains supply 1~ 230V AC L1 L2 V1 W1 N M 1~ PE O PE L3 U1 N Mains supply 3~ 400V AC L OFF L1 L2 V1 W1 U2 V2 W2 PE L3 Mains supply 3~ 400V AC U V W PE M 3~ U1 V1 W1 PE M 3~ W2 V2 U2 Şekil 3.2: Şebeke beslemesi ve motor bağlantısı (şebeke anahtarı olan pano) KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-17- 3.2 Bağlantı soketleri Hazır tesisat tüm gerekli kabloların panoya bağlanmasını sağlar. Bu kablolarda panonun ilgili soketlerine bağlanması gereken soketler bulunmaktadır. Her asansörün özelliğine göre farklı kablo setleri gerekir ve bu sebeple panoda farklı bağlantı soketleri bulunur. Aşağıdaki tablo hazır tesisatlı seri haberleşmeli kumanda panosundaki bağlantı soketlerini göstermektedir. Bağlantı soketi 1 SC8 2 2 3 3 24V 7 5 4 8 9 10 11 12 13 14 15 16 B 3 2 24V A 6 CAA 0V B COM MAN 3 2 TSG+ RSG+ 2 4 SU 2 NS 3 L2 2 L1 KILAVUZ: SERİ HAB. 4 5 PE N TL TL 1B CAM- 9 10 11 12 LED- 5 CAM+ +BAT 8 1B CAM- 8 8A N CL NDAC LDAC PE SP LED+ PE 6 1B 8 8A N CL NDAC LDAC PE • Pin adedi: 24 2 • Kablo: H05VVH6-F24 24x0,75 mm • Bağlantılar: Kabin bağlantıları • Durum: Hidrolik asansör • Pin adedi: 24 2 • Kablo: H05VVH6-F24 24x0,75 mm • Bağlantılar: Kabin bağlantıları • Durum: Mekanik asansör • Pin adedi: 12 2 • Kablo: YSLY JZ 16x0,75 mm • Bağlantılar: Kumanda panosu revizyon kutusu • Durum: Kumanda panosu revizyon kutusu • Pin adedi: 5 2 • Kablo: YSLY JB 5x0,75 mm • Bağlantılar: Hız regülatörü test & sıfırlama bobini • Durum: Test & sıfırlama bobinli hız regülatörü • • • • Pin adedi: 5 2 Kablo: 5x2,5 mm Bağlantılar: Yük kontrol aygıtı Durum: Mekanik asansör + 2:1 askı • • • • Pin adedi: 5 2 Kablo: 5x2,5 mm Bağlantılar: Yağ soğutucu Durum: Hidrolik asansör + yağ soğutucu • • • • Pin adedi: 3 2 Kablo: H05VV-F 3x1,5 mm Bağlantılar: Yağ ısıtıcı Durum: Hidrolik asansör + yağ ısıtıcı 3 PE N 5 PE L3 L1 1 PE RSG- 0V 1 5 4 TSG- 24V TL 6 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 SP 7 5 CAM+ 2 3 3 9 4 3 TL +BAT LEv2 6 PE • Kablo: H05VV-F 3x1 mm • Bağlantılar: Hız regülatörü test bobini • Durum: Test bobinli hız regülatörü TSG- 2 • Pin adedi: 12 2 • Kablo: YSLY JZ 12x0,75 mm • Bağlantılar: Kuyu dibi bağlantıları • Durum: Standart • Pin adedi: 3 PE TSG+ 8 7 DOWN UP 0V 10 11 12 CAZ+ LEv1 5 4 24V • Pin adedi: 16 2 • Bağlanan kablo: YSLY JZ 16x0,75 mm • Bağlantılar: Hidrolik ünite • Durum: Hidrolik asansör FL 3.2 NS PE 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 CAZB CAB 3 2 8 CAZA 5 3.1 INTER N230 COM INTE R230 RCOM 7 CAB 4 9 SU SUI AL 6 CAA 8 7 AL 5 4 0V 6 TL A 1 OIL HEATER 6 TL 3 2 1 OIL COOLER 3 2 1 LDC 5 SP 1 TSG • Pin adedi: 6 • Bağlanan kablo: SC9 kablosu(6) • Bağlantılar: Seri veriyolu • Durum: Standart SP 4 2 1S 1 TSG PE A48 C48 8 D12 COMTH MTH 6a B48 6bD48 COM STH 0V 1 INSPECTION BOX ED 6 B 2 10 • Pin adedi: 12 • Bağlanan kablo: SC8 kablosu (12) • Bağlantılar: Kuyu emn. devresi ve ön nihai şalterler • Durum: Standart 0V SP 0V PIT STOP FC1 5 Açıklama 9 10 11 12 EM 8A 4 A +24V 8 7 8 5 1 FC1 6 6 3 1 KC10 5 4 4 1 BUS 3 2 http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-18- 3.3 Kuyu emniyet devresi ve ön nihai şalterlerin bağlantıları - SC8 Kuyu emniyet devresi ve ön nihai şalterler SC8 adı verilen kablo demetine bağlanır. SC8’deki kablolar 81’den 87’ye kadar ve aynı numaraları içeren dört çift ile (81-81, 82-82, 83-83, 84-84) numaralandırılmıştır. Her kablo çifti aynı numaralı mavi soketlere bağlanır (3). SC8 kablo demetine tüm bağlantılar turuncu ve kırmızı soketler ile yapılır. Turuncu soketler seri bağlantıda, kırmızı soketler paralel bağlantıda kullanılır. Asansörün askı tipine göre kuyuda monte edilmesi gereken farklı emniyet devresi elemanları bulunmaktadır. Aşağıdaki resim hazır tesisat paketinin A Kutusu’nda bulunan SC8 kablo demetini göstermektedir. Metal halka (1) kablonun sonunda yer alır ve asılması için kullanılır. Soket (2) kumanda panosundaki SC8 soketine bağlanmalıdır. KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-19- 3.3.1 Sınır ve ön nihai şalterler 3.3.1.1 Hidrolik asansör - 1:1 askı, HA, HAS, HAD Blue fast connector PE 86 87 84 85 83 84 82 83 81 82 81 82 FR 638 pizzato 3x1 mm2 Blue Brown Orange fast connector TOS Upper limit switch 82 87 85 Red fast connectors FR 638 pizzato 3x1 mm2 Blue 85 Brown 87 EM Upper pre-final switch PE 86 87 84 85 83 84 82 83 81 82 81 87 86 Red fast connectors FR 638 pizzato 3x1 mm2 Blue 86 Brown 87 ED Lower pre-final switch PE 86 87 84 85 83 84 SC8 connector Connect to the controller SC8 terminal strip. *ATTENTION. Make sure that the 81 numbered wire is connected to the 2 terminal KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr SC8 82 83 81 82 81 SC8 terminal strip 2 3 4 5 6 8A 8 10 EM ED 0V PE SC8 wire numbers 81 81 82 82 83 83 84 84 85 86 87 Yellow/Green Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-20- 3.3.1.2 Hidrolik asansör - 1:2 askı tek piston, HAI Blue fast connector PE 86 87 84 85 83 84 82 83 81 82 81 82 FR 638 pizzato 3x1 mm2 Blue Brown Orange fast connector PLS Piston limit switch 82 PE 86 87 84 85 83 84 82 83 81 82 81 82 FR 638 pizzato 3x1 mm2 Blue Brown Orange fast connector TOS Upper limit switch 82 87 85 Red fast connectors FR 638 pizzato 3x1 mm2 Blue 85 Brown 87 EM Upper pre-final switch PE 86 87 84 85 83 84 82 83 81 82 81 87 86 Red fast connectors FR 638 pizzato 3x1 mm2 Blue 86 Brown 87 ED Lower pre-final switch PE 86 87 84 85 83 84 SC8 connector Connect to the controller SC8 terminal strip. *ATTENTION. Make sure that the 81 numbered wire is connected to the 2 terminal KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr SC8 82 83 81 82 81 SC8 terminal strip 2 3 4 5 6 8A 8 10 EM ED 0V PE SC8 wire numbers 81 81 82 82 83 83 84 84 85 86 87 Yellow/Green Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-21- 3.3.1.3 Hidrolik asansör - 1:2 askı çift piston, HADI Blue fast connector PE 86 87 84 85 83 84 82 83 81 82 81 82 FR 638 pizzato 3x1 mm 2 Blue Brown Orange fast connector PLS A Piston A limit switch 82 PE 86 87 84 85 83 84 82 83 81 82 81 82 FR 638 pizzato 3x1 mm 2 Blue Brown Orange fast connector PLS B Piston B limit switch 82 PE 86 87 84 85 83 84 82 83 81 82 81 82 FR 638 pizzato 3x1 mm 2 Blue Brown Orange fast connector TOS Upper limit switch 82 PE 86 87 84 85 83 84 82 83 81 82 81 87 85 Red fast connectors FR 638 pizzato 3x1 mm 2 Blue 85 Brown 87 EM Upper pre-final switch PE 86 87 84 85 83 84 82 83 81 82 81 87 86 Red fast connectors FR 638 pizzato 3x1 mm 2 Blue 86 Brown 87 ED Lower pre-final switch PE 86 87 84 85 83 84 SC8 connector Connect to the controller SC8 terminal strip. *ATTENTION. Make sure that the 81 numbered wire is connected to the 2 terminal KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr SC8 82 83 81 82 81 SC8 terminal strip 2 3 4 5 6 8A 8 10 EM ED 0V PE SC8 wire numbers 81 81 82 82 83 83 84 84 85 86 87 Yellow/Green Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-22- 3.3.1.4 Mekanik asansör Blue fast connectors PE 86 87 84 85 83 84 82 83 81 82 81 82 FR 638 pizzato 3x1 mm 2 Blue Brown Orange fast connector TOS Upper limit switch 82 87 85 Red fast connectors FR 638 pizzato 3x1 mm 2 Blue 85 Brown 87 EM Upper pre-final switch PE 86 87 84 85 83 84 82 83 81 82 81 87 86 Red fast connectors FR 638 pizzato 3x1 mm2 Blue 86 Brown 87 ED Lower pre-final switch 82 FR 638 pizzato BOS Lower limit switch 3x1 mm 2 Blue Brown Orange fast connector 82 PE 86 87 84 85 83 84 SC8 connector Connect to the controller SC8 terminal strip. *ATTENTION. Make sure that the 81 numbered wire is connected to the 2 terminal KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr SC8 82 83 81 82 81 SC8 terminal strip 2 3 4 5 6 8A 8 10 EM ED 0V PE SC8 wire numbers 81 81 82 82 83 83 84 84 85 86 87 Êßôñéí ï /ĞñÜóéí ï Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-23- 3.3.2 Hız regülatörü ve halat gevşeme kontakları 3.3.2.1 Hidrolik asansör, HADI Blue fast connector PE 86 87 OGSC Overspeed governor switch 84 85 83 84 82 83 81 82 81 82 3x1 mm2 Blue Brown Orange fast connector 82 PE 86 87 84 85 83 84 82 83 81 82 81 81 FR 638 pizzato 3x1 mm2 Blue Brown Orange fast connector SRS2 Slack rope switch 2 81 81 FR 638 pizzato SRS1 Slack rope switch 1 3x1 mm2 Blue Brown Orange fast connector 81 PE 86 87 84 85 83 84 SC8 connector Connect to the controller SC8 terminal strip. *ATTENTION. Make sure that the 81 numbered wire is connected to the 2 terminal KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr SC8 82 83 81 82 81 SC8 terminal strip 2 3 4 5 6 8A 8 10 EM ED 0V PE SC8 wire numbers 81 81 82 82 83 83 84 84 85 86 87 Yellow/Green Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-24- 3.3.2.1 Mekanik asansör Blue fast connectors PE 86 87 84 85 83 84 82 83 81 82 81 OGSC Overspeed governor switch 82 3x1 mm 2 Blue Brown Orange fast connector 82 81 3x1 mm 2 Blue Brown Orange fast connector 81 SRS Slack rope switch (lift suspension 2:1) PE 86 87 PE 84 85 86 87 83 84 84 85 83 84 SC8 connector Connect to the controller SC8 terminal strip. *ATTENTION. Make sure that the 81 numbered wire is connected to the 2 terminal KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr 82 83 SC8 81 82 82 83 81 81 82 81 SC8 terminal strip 2 3 4 5 6 8A 8 10 EM ED 0V PE SC8 wire numbers 81 81 82 82 83 83 84 84 85 86 87 Yellow/Green Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-25- 3.3.3 Kat kapıları emniyet devresi 3.3.3.1 Yarı otomatik kapılar Blue fast connector PE 86 87 Door lock Black Orange fast connector 81 82 81 GN/YL 84 83 GN/YL Black 3x1 mm 2 82 83 Green/Yellow Grounding point Door contact 83 84 84 GN/YL Black 3x1 mm 2 84 85 Green/Yellow Black Orange fast connector GN/YL 83 Semiautomatic landing door Level-N PE 86 87 Door lock Black Orange fast connector 81 GN/YL 84 Green/Yellow Black Orange fast connector GN/YL 83 Semiautomatic landing door Level-0 PE 86 87 84 85 83 84 SC8 connector Connect to the controller SC8 terminal strip. *ATTENTION. Make sure that the 81 numbered wire is connected to the 2 terminal KILAVUZ: SERİ HAB. 81 82 83 GN/YL Black 3x1 mm 2 82 83 Green/Yellow Grounding point Door contact 83 84 84 GN/YL Black 3x1 mm 2 84 85 http://www.kleemannlifts.com.tr SC8 82 83 81 82 81 SC8 terminal strip 2 3 4 5 6 8A 8 10 EM ED 0V PE SC8 wire numbers 81 81 82 82 83 83 84 84 85 86 87 Yellow/Green Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-26- 3.3.3.2 Otomatik kapılar Blue fast connector PE 86 87 Door lock 83 84 82 83 81 82 81 84 GN/YL Black 3x1 mm 2 84 85 Green/Yellow Black Grounding point Orange fast connector GN/YL 84 Automatic landing door Level-N PE 86 87 Door lock 83 84 82 83 81 82 81 84 GN/YL Black 3x1 mm 2 84 85 Green/Yellow Black Grounding point Orange fast connector GN/YL 84 Automatic landing door Level-0 PE 86 87 84 85 83 84 82 83 81 82 81 SC8 connector Connect to the controller SC8 terminal strip. *ATTENTION. Make sure that the 81 numbered wire is connected to the 2 terminal KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr SC8 Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-27- 3.4 Hidrolik ünite bağlantıları - KC10 3.4.1 BLAIN valf bloğu Hidrolik ünite elemanı Yukarı yön düşük hız valf bobini Yukarı yön yüksek hız valf bobini Aşağı yön yüksek hız valf bobini Aşağı yön düşük hız valf bobini Valf bloğu Acil indirme bobini Motor termistörü Termistörler Yağ termistörü Aşırı yük basınç anahtarı Düşük basınç anahtarı Tam yük basınç anahtarı Mekanik basınç anahtarları Voltaj beslemesi Elektronik basınç anahtarı Aşırı yük kontağı Tam yük kontağı KC10 soketi A48 COM B48 COM C48 COM D48 COM D12 COM STH COMTH MTH COMTH 0V SU/SUI 3.1 3.2 0V FL/NS 0V 24V SU/SUI FL/NS KC10 kablo no 1 6 2 6 3 6 4 6 5 6 8 7 9 7 10 11 13 14 10 15 10 12 11 15 Tablo 4.1 Blain valf bloklu hidrolik ünite bağlantıları KC-10 A48 B48 2 C48 3 D12 5 4 16x0.75 mm 2 6 COMTH 7 STH 8 MTH 9 PE PE FL/ NS 2 1B 1B 24V 2 4V S U/S UI 0V SU/ SUI 0V MTH MTH S TH C10 8 7 6 5 D12 C48 10 9 C48 B48 12 11 STH C OMTH C OMTH COM 15 13 4 3 B48 A48 FL/NS PE FL 3.2NS PE 15 16 D48 D48 D12 KC-10 14 3.2 3.1 3.1 13 14 FL/NS 24V 24V 12 2 SU/SUI 11 COM 0V 10 A48 COM SU SUI KC-10 D48 A48 C48 D12 COMTH MTH B48 D48 COM STH 0V Connect to the controller's KC-10 terminal strip Connect to the valve block KC-10 terminal strip 1 2 1 YELLOWGREEN Blain valve block KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-28- 3.4.2 Bucher valf bloğu Hidrolik ünite elemanı Aşağı yön valf bobini Valf bloğu Yukarı yön valf bobini Acil indirme bobini Motor termistörü Termistörler Yağ termistörü Aşırı yük basınç anahtarı Düşük basınç anahtarı Tam yük basınç anahtarı Mekanik basınç anahtarları Voltaj beslemesi Elektronik basınç anahtarları Aşırı yük kontağı Tam yük kontağı KC10 soketi 6a 7 6b 8 D12 COM STH COMTH MTH COMTH 0V SU/SUI 3.1 3.2 0V FL/NS 0V 24V SU/SUI FL/NS KC10 kablo no 1 2 3 4 5 6 8 7 9 7 10 11 13 14 10 15 10 12 11 15 Tablo 4.2 Bucher valf bloklu hidrolik ünite bağlantıları KC-10 C48 3 D12 5 B48 A48 4 STH MTH 7 8 9 10 PE PE FL/NS 2 FL/NS SU/SUI 0V 2 0V MTH 11 10 9 MTH C10 STH 13 STH COMTH 14 8 7 COMTH COM 15 6 8 5 4 3 7 6a 6a FL/NS 15 16 12 COM D12 8 D12 6b 6b 7 3.2 14 KC-10 3.1 13 SU/SUI 1B 1B 24V 12 24V SU/SUI 11 24V 0V KC-10 16x0.75 mm2 6 COMTH COM Connect to the controller's KC-10 terminal strip Connect to the valve block KC-10 terminal strip 2 D48 PE SU A48 C48 D12 COMTH MTH 3.1 FL SUI 3.2NS PE B48 D48 COM STH 0V 24V 1 2 1 YELLOWGREEN Bucher valve block Descent valve coil Ascent valve coil Bucher feedback cable NTA-2 Power supply unit (placed in the controller) KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-29- 3.5 Kuyu dibi bağlantıları – PIT STOP Kuyu dibi bağlantıları Kuyu dibi emniyet devresi Telefon soketi Alarm butonu Interkom aygıtı 230V AC soketi PIT STOP soketi 1S 2 TL TL AL AL INTERCOM INTERCOM R230 N230 PE PIT STOP kablo no 1 2 4 5 6 7 8 9 10 11 GN/YL PIT STOP SP 3 2 SP 12x0.75mm 2 4 TL TL TL TL 5 6 AL AL AL 7 8 INTER N230 INTE COM R230 RCOM PE PE INTER N230 COM INTE R230 RCOM AL Connect to the conroller's PIT STOP terminal strip PIT STOP 2 2 1S 1S 1 9 10 11 Yellow/Green STOP TL PIT STOP INTERCOM Slave Intercommunication device INTERCOM KD-600 3x1mm 2 KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-30- Çift pistonlu bir 1:2 askı hidrolik asansörde (HADI) veya bir mekanik asansörde fren tertibatını çalıştırmak için kuyuya hız regülatörü monte edilir. Hız regülatörünün ağırlık kontağı emniyet devresine kuyu dibi durdurucusundan (Pit stop) bağlanır. Overspeed governor PIT STOP SP 3 TL 5 2 SP 12x0.75mm 2 4 TL TL TL 6 AL AL AL 7 8 INTER N230 PE PE INTER N230 COM INTE R230 RCOM INTE COM R230 RCOM AL Connect to the conroller's PIT STOP terminal strip PIT STOP 2 2 1S 1S 1 9 10 11 YELLOWGREEN STOP TL PIT STOP Brown Green/ Yellow INTERCOM Slave Blue KD-600 3x1mm 2 Connect the overspeed governor 's tension device switch cable Overspeed governor 's tension device 3x1mm 2 KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-31- 92 91 94 93 95 96 3.6 Kat butonları 93 3 91 92 94 4 2 1 ON 2 ON 3 ON 4 ON 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 6 ON 7 ON 8 ON 9 ON 10 ON 11 ON 12 ON 13 ON 14 ON 15 ON 1 2 3 4 5 6 4 3 2 1 6 1 2 3 4 5 6 IC1 Diagram 2 Connection of the L.O.P.'s cable DS1 ON DS1 5 DS1 1 1 2 3 4 5 6 DS1 ON DS1 6 Wires 91 92 93 94 95 96 0 DS1 6 Connector 1 2 3 4 Dip Switches SL-IO DS1 Diagram 1 Connection of the BUS braid of wires to the black connector 95 96 Level IC2 PH1 DS1 IC5 IC4 SL-IO IO5 IO6 IO7 IO8 DS1 1 2 3 4 5 6 DS1 1 2 3 4 5 6 DS1 1 2 3 4 5 6 DS1 1 2 3 4 5 6 IC6 IC1 IC2 PH1 1 2 3 4 5 6 DS1 1 2 3 4 5 6 ON Diagram 3 L.O.P. cable connection board, connected to the SL-IO 4 3 2 1 1 2 3 4 5 6 DS1 6 1 2 3 4 5 6 DS1 L.O.P. cable connection board 1 2 3 4 5 6 DS1 IO1 IO2 IO3 IO4 1 2 3 4 5 6 DS1 1 2 3 4 5 6 ON SL-IO bus module DS1 SL-IO IC6 KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-32- 3.7 Kabin kapıları 3.7.1 Otomatik kabin kapısı, KRAMER tipi 220V 230V - N / 1A. PE 230V - L / 1A. Blue Yellow Green Brown ENTRADAS OPEN Bus door command cable 3x1mm 2 0V ~230V 50/60Hz Prim:4200/0.07 Sec:2*140/0.28 COM 12V CLOSE BUS door power supply cable 3x1mm2 Blue Brown RELLANO Magnetic switch BATERIA BATTERY Battery 12 VDC BATTERY + RELET SERIE Brown Bus door contact cable 3x1mm 2 Blue Car Revision KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 KILAVUZ: SERİ HAB. Light curtain connections Automatic door cable 16x0,75mm2 installed, short circuit wire No5 with the blue wire. * In case there is no light curtain 4 5 * BLUE M 39 40 41 36 37 38 33 34 35 30 31 32 Revision Box Car door contact connection 12 13 6 8 9 55. ENCODER 56. MOTOR .......OK! DO NOT OPER THE COVER KLEFER STATUS OBSTRUCTION PHOTOCELL CLOSED OPENED MASTER ON LEFT & CENTRAL ON 4 SAFETY OFF 3 http://www.kleemannlifts.com.tr TEST ? 15 14 13 10 (VVVF-4) 12 (VVVF-4) 8 (VVVF-4) Light curtain supply Light curtain supply 7 (VVVF-4) DC +24V 0V CS1 3 4 5 6 30 (VVVF-4) 66 (Emergency supplier) 67 (Emergency supplier) Door contact Door contact EDO1 EDO1 7 8 9 10 11 12 13 1 (Emergency supplier) 3 (Emergency supplier) 2 (Emergency supplier) NDAC PE 15 Yellow/Green 14 33 (VVVF-4) DCL1 DOL1 8 7 19 18 17 ÁÕÔÏ Ì ÁÔÇ ÐÏ ÑÔÁ V+ 16 V- 8 12 11 10 9 20 26 21 25 23 RX TX SERIAL PORT DO PUSH TO CHECK THE DOOR WHITE RECEIVER GREEN BLACK BLACK EMITTER YELLOW WHITE PHOTOCELL C-D 50 PUSH TO CALIBRATE THE DOOR AUTOADJUSTMENT 51 1 ON OFF FLOOR LEVER RE-OPEN SLOW CLOSE +12V COM PRIORITY INPUTS OPEN 0V COM OUT+12V CLOSE INPUTS 7 6 100.230F 5 N SUPLPLY GND 2 4 321 Use only fuse 4 Amps/250Volt SP F 2 INPUT OFF MANUAL LANDING DOOR ÊÙÄÉÊÏ Ó + + + OFF CLOSE +12Volt Com 1 INPUT 0Volt OPEN ON AUTOMATIC LANDING DOOR CLOSE +12Volt Com 0Volt OPEN ON Á/Á - - - 1 2 LDAC CLOSE SPEED 52 OPEN SPEED 53 54 SLAVE RIGHT OFF 1 3 2 + +29 BATTERY - -28 CONTROL VVVF4 FLOOR +12V COM 26 23 11 10 67 66 FLOOR KLEFER 5 Êßôñéí ï / ĞñÜóéí ï 3 2 14 1 L3 GND L2 SUPPLY 230V.AC OUTPUT VVVF4 Magnetic switch for emergency door opening signal 15 EMERGENCY SUPPLIER 6 L2' GND L1' 7 ÁÐÅÃÊËÙÂÉÓÌ Ï Ó ON BAT BATTERY FUSE 20A (yellow) STANDBY Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-33- 3.7.2 Otomatik kabin kapısı, VVVF tipi Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-34- 3.8 Kabin bağlantıları Revision Box REV B A 0V 2 4V REV1 2 PE CL 5 TL 1 Connection to the REV1 terminal strip Connection to the SL-DIS board 1 2 Travelling cable FC1 24x0.75mm2 C.O.P. connection cable 16x0.34mm2 Connect to the controller's FC1 terminal strip FC1 2 4V KILAVUZ: SERİ HAB. A 6 B 8 8A *The cable is connected to the MC1 connector of the SL-COP board (paragraph 3.8) N CL PE http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-35- 3.9 Kabin butonyeri iç bağlantılar Car Operating Panel DISPLAY OVL 1 TB1 MC1 1 MC2 MC1 connector C.O.P. cable connection SL-COP FAN SW2 SW 8 SW2 LED+ SW1 SW2 LED- LED+ 7 SW1 SW2 SW1 SW2 LED- LED+ LED- LED+ SW1 SW2 SW1 SW2 LED- LED+ LED- LED+ SW1 SW2 SW1 SW2 LED- LED+ LED- LED+ SW1 SW2 SW1 SW2 LED- LED+ LED- LED+ SW1 SW2 SW1 SW2 LED- LED+ LED- LED+ SW1 SW2 SW1 SW2 LED- LED+ LED- LED+ SW1 SW2 SW1 SW2 LED- LED+ LED- LED+ SW1 SW2 SW1 SW2 LED- LED+ LED- LED+ 6 5 3 4 2 1 D.O. KILAVUZ: SERİ HAB. SW1 LED- D.C. SW1 SW1 LED- LED- http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-36- Bölüm 4. Parametreler 4.1 Parametre programlama Aşağıdaki şekil menü içeriği ve parametre programlamaya bir örnektir. Resend Enter Esc PARAMETERS PROGRAMMING Enter Esc Right GENERAL TIMERS Right PARAMETERS LEVEL FUNCTIONS Left PARAMETERS OF DOOR FUNCTIONS Left Enter Esc Right TYPE OF DOOR Right DOOR SIGNALS PERMANENT Right PARKING WITH OPEN DOORS Left ........... Left × ÑÏ Í Ï Ó ÁÍ Ï É× Ô. È ÕÑÁÓ ÓÔÇÍ ÓÔÁÓÇ Left Enter Esc 3-45 TDoorDA Press UP or DOWN to change the parapeters value and then press ENTER to save the value Seconds 06 Up 3-45 TDoorDA Seconds 08 Enter 3-45 TDoorDA Seconds 08 Auto Return 4.2 Ek özellikler Kumanda panosunun revizyon modu açık olduğunda menüde bazı ek özellikler erişilebilir olur. Resend (3) (1) Up (2) (6) (5) Left (4) Right Enter Esc Down • • • • Göstergeyi taramak ve program sürümünü görmek için Left (1) ‘e basın. Menünün dilini seçmek için Right (2) ‘ye basın. Kabin çağrıları kaydı vermek için Up (3) ‘a basın. Kabinin konumu ve durumunu görüntülemek Right (2) ve Down (4) ‘a aynı anda basın. KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-37- 4.3 Parametre analizi Seri haberleşmeli panonun menüsü yedi ana kategoriye ayrılmıştır: • Parametre programlama. Bu kategori montaj özellikleri ve asansörün çalışmasyla ilgili tüm parametreleri içerir. • Arıza geçmişi. Hatal kayıtları ve işlenmesi bulunmaktadır. Kaydedilen bilginin açıklaması bölüm 5.1’de anlatılmaktadır. • Sistem güvenlik. Bu kategoriden menüye erişim için şifre belirlenebilir. • Tarih ve saat ayarı. Tarih ve saat ayarları yapılır. Hata kayıtları bu ayarlara göre şekillenir. • Varsayılan parametreler. Farklı montaj tipleri için varsayılan ayarları içerir. • Gizli fonksiyonlar. Sadece şifre ile erişilebilien parametreleri içerir. • GSM parametreleri. GSM aygıt ayarları için kullanılır. 4.3.1 Parametre programlama kategorisi. Bu kategorideki parametreler aşağıdaki tablolarda anlatılan yedi alt kısma ayrılır. 4.3.1.1 Genel Zaman Ayarı Parametre TRAVEL TIMER HIGH SPEED (TTravf) TRAVEL TIMER SLOW SPEED (TTravS) YÜKSEK HIZDA SEYİR ZAMANI (TTravf) DÜŞÜK HIZDA SEYİR ZAMANI (TTravS) TRAVEL TIMER RELEVELING (TReLev) SEVİYELEME ZAMANI (TReLev) ON LEVEL BETWEEN CALLS (TCarIdle) ÇAĞRI ZAMANI (TCarIdle) AUTO PARKING TIMER (TParking) PARK SÜRESİ (TParking) SERVICE DAYS (TSDays) SERVİS GÜNÜ (TSDays) STAND BY TIME (TSMinutes) BEKLEME ZAMANI (TSMinutes) Açıklama Değer aralığı Bir kattan diğerine yüksek hızdaki maksimum seyir zamanını belirler (hedef kata ulaşıldığındaki hız değişimine kadar). 20-60 Saniye Hız değişim noktası ile kat seviyesi arasında düşük hız maksimum seyir zamanını belirler. 6-45 Saniye Sistemin seviyeleme fonksiyonunu gerçekleştirmesi için izin verilen maksimum zamanı belirler. 0-15 Saniye Kabin kapısı olmayan asansör (kata ulaştığında kabin kapısı emniyeti olmadığından otomatik olarak durdurulan). Kabinin bir sonraki hareketin başlangıcına kadar katta bekleme süresini belirler (henüz ulaşıp halen kayıtlı çağrıları olan). Bu süre sadece kabin bir kata ulaşıp kat kapısı açılmadığı durumda geçerlidir. Park süresini belirler. Kabin bir katta durup belirlenen süre kadar bekledikten sonra belirlenen park katına ("Kat bilgisi>Park durağı ayarı ") otomatik hareket gerçekleştirir. Parametre değeri “0” ise fonksiyon kapalıdır. Diğer durumlarda fonksiyon açıktır ve geri sayım başlar. Geri sayım 0’a ulaştığında asansör servis dışı olur. Kumanda panosu revizyonu açılıp kapatıldığında asansör normal çalışmaya döner. Enerji tasarrufu fonksiyonu. Eğer parametre “0” ise fonksiyon kapalıdır. Diğer durumlarda fonksiyon açık ve geri sayım başlamıştır. Geri sayım 0’a ulaştığında asansör bekleme moduna geçer. 0-10 Saniye 0-10 Dakika 0-999 Gün 0-99 Dakika 4.3.1.2 Kat Bilgisi Parametre NO OF FLOORS FROM (2-16) (NFloor) PARKING LEVEL CHOISE (NParking) KILAVUZ: SERİ HAB. Açıklama Değer aralığı DURAK ADEDİ (2-16) (NFloor) Durak sayısını belirler. 2-16 Kat PARK DURAĞI (NParking) Park durağını belirler. 0-15 Kat http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-38- 4.3.1.3 Kapı Bilgisi Parametre TYPE OF DOOR (DType) DOOR SIGNALS PERMANENT (DcExtend) PARKING WITH OPEN DOORS (ParkADoO) DR CL TIME AFT CAR CALL ENABLE (TCDACallEn) DOOR CLOs TIME AFTER CAR CALL (TCDACall) KABİN ÇAĞRISI SONRASI KAPI KAPANMA SÜRESİ AKTİF (TCDACallEn) KABİN ÇAĞRISI SONRASI KAPI KAPANMA SÜRESİ (TCDACall) DOOR OPEN TIME ON LEVEL (TDoorDA) KAPI AÇIK BEKLEME SÜRESİ (TDoorDA) DOOR CLOSING TIME-OUT TIME (TDoorCOD) KAPI KAPANMA SÜRESİ (TDoorCOD) DOOR POS. OPEN ON OUT OF ORDER (O3DOpen) NO CAR DOOR FUNCTION (NCDFun) SERVİS DIŞI MODUNDA KABİN KAPISI AÇIK (O3DOpen) KABİN KAPISI YOK (NCDFun) Açıklama Değer aralığı KAPI TİPİ (DType) Kabin kapısı tipini belirler. 0-1 “0” = Kramer veya kapı yok “1” = Otomatik KAPI SİNYALİ DC (DcExtend) Otomatik kabin kapısına hareket esnasında gelen sürekli kapı kapama sinyalinin etkinleştirilmesi. EVET - HAYIR KAPI AÇIK BEKLEME (ParkADoO) Katta kabin kapısı açık bekleme. EVET - HAYIR Bu fonksiyonu etkinleştirir: Kapı kapama sinyali kabin çağrılarına bağlıdır. Kabinden çağrı yapıldığında pano aşağıdaki parametrede belirlenen süreden geri saymaya başlar ve sonrasında kapıyı kapatır. EVET - HAYIR Üstteki parametreyi kontrol edin. 0-2 Saniye Sonraki kayıtlı çağrı gerçekleştirilmeden önce otomatik kabin kapısının katta açık bekleme süresini belirler (kapının açılması için gerekli süreyi de içerir). Tanımlanmış süre kapı açma sinyali verildiğinde başlar, sürenin bitiminde kapı kapama sinyali verilir. Otomatik kabin kapısının kapanması için gerekli süreyi belirler. Süre kapı kapama sinyali verildiğinde başlar. Sürenin sonunda kabin kapısı emniyeti “8” ve kat kapısı emniyeti “10” kapamalıdır. Süre bittiğinde bu sağlanmazsa kapı kapama sinyalini takip eden yeni bir kapı açma sinyali verilir. Anakart emniyet devresini tamamlamak için kapıyı 5 defa açar ve kapatmaya çalışır. 5 inde de bu sağlanamaz ise “49 KAPI KAPATMA HATASI” verilir ve tüm kayıtlı çağrılar iptal edilir. 3-45 Saniye 3-45 Saniye “Servis dışı” (O3I girişi etkin) fonksiyou esnasında kabin kapısı açık kalmalı. EVET - HAYIR "Kapı tipi = 0". Yarı otomatik kat kapısı açık olduğunda çağrı kaydı yapılamaz. EVET - HAYIR 4.3.1.4 Seyir Bilgisi Parametre CHOICE OF LIFT TYPE (LType) CALL AUTOM/TIO SELECT (CallAuto) A3 FUNCTION ACTIVATION (A3FunEn) RELEVEL FUNCT. IN VVVF MOD (RAIVvvf) KILAVUZ: SERİ HAB. ASANSÖR TİPİ (LType) ÇAĞRI OTOMASYONU SEÇİMİ (CallAuto) A3 FONKSİYONU ETKİNLEŞTİRME (A3FunEn) VVVF MODUNDA SEVİYELEME (RAIVvvf) Açıklama Asansör tipi seçimi Çağrı otomasyonu seçimi Değer aralığı 0-3 "0" = Hidrolik "1" = Mekanik çift hızlı "2" = Mekanik tek hızlı “3” = Mekanik VVVF 0-2 "0" = Tek otomatik "1" = Aşağı yön toplamalı "2" = Çift yön toplamalı Kumanda panosunun kontrolsüz kabin hareketine özel fonksiyonlarını etkinleştirir. EVET - HAYIR Mekanik VVVF asansörde seviyeleme fonsiyonunu etkinleştirir. EVET - HAYIR http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU CAR CALL PRIOR TIME (DPCall) MOTOR DELAY STOP DELAY (TStop) VALVE DELAY STOP TIME (TValve) Υ/∆ TIMER START TIME (TStDel) INTERMED VVVF SPEED ACTIVATION (ISType) END OF MOTION DELAY ACTIVATION (IAMode) END OF MOTION DELAY SETTING (TAVVVF) END OF MOTION DELAY DOWN (TStopDown) CAR-LANDING COMMON (CLSame) BUCHER ACTIVATION (Bucher) KABİN ÇAĞRI ÖNCELİĞİ SÜRESİ (DPCall) YUMUŞAK DURUŞ SÜRESİ A (TStop) YUMUŞAK DURUŞ SÜRESİ B (TValve) Sayfa-39- Kabin katta durduğunda bu parametredeki süre boyunca kabin çağrılarının kat çağrılarına karşı önceliği vardır. 3-15 Saniye Hidrolik asansörde motorun devredışı kalması için gecikme süresi. 0-3000 Millisaniye Hidrolik asansörde aşağı yön düşük hız bobininin devredışı kalması için gecikme süresi. 0-5000 Millisaniye Υ/∆ SÜRESİ (TStDel) Hidrolik asansörde Yıldız – Üçgen geçiş süresi EVET - HAYIR ARA VVVF HIZI ETKİNLEŞTİRME (ISType) Mekanik VVVF parametresi etkinleştirildiğinde peşpeşe katlar arası hareket ara hız ile gerçekleşir. EVET - HAYIR HAREKET SONU GECİKME ETKİNLEŞTİRME (IAMode) Parametre etkinleştirildiğinde “FM” ve “FD” hareket sinyalleri belirlenecek süre boyunca devredışı kalır. Mekanik VVVF’de kullanılır ve sürücü tarafından yapılan asansörün elektriksel duruşunda yardımcı olur. EVET - HAYIR HAREKET SONU GECİKME AYARI (TAVVVF) Mekanik VVVF: Hareket sinyallerinin devre dışı kalma süresi 0-5000 Millisaniye Hidrolik asansör Bucher. Aşağı yönde hareketin devre dışı kalması için gecikme süresi 0-1000 Millisaniye Parametre etkinleştirildiğinde kabin ve kat çağrıları eş zamanlı etkinleştirilir. EVET - HAYIR Hidrolik asansör VVVF - Bucher. SL-MAIN anakartının “VVVF” girişi etkinleştirilir. EVET - HAYIR HAREKET SONU AŞAĞI YÖN GECİKME (TStopDown) KABİN-KAT ORTAK (CLSame) BUCHER ETKİNLEŞTİRME (Bucher) 4.3.1.5 Yangın İhbarı Bilgisi Parametre Açıklama Değer aralığı DEFINE FIREMAN TYPE (Fire) YÖNETMELİK SEÇME (Fire) Yönetmelik tipi tanımlama 0-2 "0" = Yangın ihbarı yok "1" = Fransız yönetmeliği "2" = İngiliz yönetmeliği DEFINE FIREMAN LEVEL (ΝFire) DURAK BELİRLEME (ΝFire) “FIR” girişinin etkinleştirilmesinde asansörün otomatik olarak hareket edeceği durağı belirler. 0-16 durak 4.3.1.6 Kayıt Sinyali Parametreleri Parametre NEXT DEPARTURE ARROWS (NDArrows) CALL REGISTRY FLASHING (CalFls) DIRECT. ARROWS FLASHING (ArrFls) KILAVUZ: SERİ HAB. Açıklama Değer aralığı SONRAKİ HAREKET OKLARI (NDArrows) Sonraki yön oklarının etkinleştirilmesi EVET - HAYIR KABİNDEN KAYIT SİNYALİ (CalFls) Kabin çağrısından sonra kayıt alınan durağın butonunda ışık yanıp sönmesi EVET - HAYIR YÖN OKLARI (ArrFls) Yön oklarının yanıp sönmesi EVET - HAYIR http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU LANDING CALLS FLASHING (ExDFls) KATLARDAN KAYIT SİNYALİ (ExDFls) CAR LIGHTS TIMER (TLight) TIMER LIFT IN USE (TCl) GONG ACTIVATION POINT (GTrPos) GONG PULSE DURATION (TGong) FM-FD OUTPUTS ON IOSP3 AND 4 (ArrowsIo) Sayfa-40- Çağrı butonuna basıldığında ledi yanıp söner. EVET - HAYIR Meşgul sinyali kesildikten sonra kabin ışıkların açık kalacağı süre 0-60 Saniye Kullanılmıyor. 0-60 Saniye Gong sinyali etkinleştirme noktası 0-1 "0" = Kata varışta "1" = Kata gelmeden GONG SÜRESİ (TGong) Gong sinyali süresi. 100-3000 Millisaniye IOSP3 VE 4’DE FM-FD ÇIKIŞLARI (ArrowsIo) IOSP3 ve IOSP4 SL-MAIN kartının serbest programlanabilir giriş/çıkışları yön okları olarak programlanmıştır (FM, FD) EVET - HAYIR KABİN AYDINLATMA SÜRESİ (TLight) MEŞGUL SÜRESİ (TCl) GONG ETKİNLEŞTİRME NOKTASI (GTrPos) 4.3.1.7 Veriyolu Parametreleri SL-COP1 Parametreleri Parametre ΑΝΑΠΑΡΑΓΩΓΗ ΣΗΜΑΤΩΝ VOC (Cop1Voc) CAR CALL REG. SOUND EN 8170 (Cop1Beep) DC AND DO ACTIVATION Açıklama Değer aralığı VOC İŞARETİ ÜRETME (Cop1Voc) Bu parametrenin etkinleştirilmesi anons biriminin kırmızı SLCOP1 soketine bağlanmasına izin verir. EVET - HAYIR KABİN ÇAĞRI KAYIT SESİ (EN 81-70) (Cop1Beep) Kabin çağrı butonlarına basıldığında sesli uyarı EVET - HAYIR KAPI AÇMA VE KAPI KAPAMA SİNYALLERİNİ ETKİNLEŞTİRME SL-COP1’de kapı açma ve kapı kapama sinyallerinin etkinleştirilmesi. EVET - HAYIR SL-DIS Parametreleri Parametre ED AND EM ON SL-DIS (DisEdEm) SU ON SL-DIS (DisSu) FL ON SL-DIS (DisFl) FIR ON SL-DIS (DisFir) SL-DIS ÜZERİNDE ED VE EM (DisEdEm) SL-DIS ÜZERİNDE SU (DisSu) SL-DIS ÜZERİNDE FL (DisFl) SL-DIS ÜZERİNDE FIR (DisFir) Açıklama Değer aralığı SL-DIS kartı ön nihai şalter girişlerinin etkinleştirilmesi (EM, ED) DİKKAT! SL-MAIN’deki eşdeğer girişleri devre dışı kalacaktır.. EVET - HAYIR SL-DIS kartı aşırı yük girişinin etkinleştirilmesi (SU) DİKKAT! SL-MAIN’deki eşdeğer girişi devre dışı kalacaktır. EVET - HAYIR SL-DIS kartı tam yük girişinin etkinleştirilmesi (FL) DİKKAT! SL-MAIN’deki eşdeğer girişi devre dışı kalacaktır. EVET - HAYIR SL-DIS kartı yangın ihbar girişinin etkinleştirilmesi (FIR) DİKKAT! SL-MAIN’deki eşdeğer girişi devre dışı kalacaktır. EVET - HAYIR SL-IO Parametreleri Parametre VVVF AND FPR ON Ι/Ο (IoVvvfFpr) KILAVUZ: SERİ HAB. I/O ÜZERİNDE VVVF VE FPR (IoVvvfFpr) Açıklama Bir SL-IO veriyolu modülünde "VVVF" (sürücü hatası) ve “FPR” (kontaktörler izleniyor) etkinleştirilir. DİKKAT! SL-MAIN’deki eşdeğer girişi devre dışı kalacaktır. http://www.kleemannlifts.com.tr Değer aralığı EVET - HAYIR Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-41- Bölüm 5. Hatalar 5.1 Hata kontrolü Anakart parametre menüsündeki “Hata tespiti” kategorisinde hata kayıtları ve hatanın kaydedildiği andaki asansörün durumuyla ilgili bilgiler mevcuttur. Bilgiler hata kaydedildiği andaki konum, yön, hız, kabin hedefi, saat ve tarihi içerir. Aşağıdaki örnek bir Mekanik VVVF’li asansörde hata kontrolünü göstermektedir. (6) CHECK FAULT HISTORY (6) CHECK ERROR HISTORY (1) ERROR Enter Enter Í ï ( 2) Automatic display switch 36 TRAVEL TIMER Down (1) Í ï ( 1) Automatic display switch (1) ED Right (4) ERROR (A) A C FM P= 00 D= 02 =0 Right (Ã) A FD P= 28 D= 03 43 EM ACTIVATED AT WRONG TIME (B) DESTINATION 12/06 09:30 (1) EM Right (Ä) DESTINATION 12/06 09:15 =3 Right Gösterge açıklamaları (A) A C FM P= 00 D= 02 • ED Gösterge (Α). Üst satır: A C. Anakartın A ve C röleleri etkin, buna göre yüksek hız (Mekanik VVVF). FM. Yukarı yön etkin ED. Alt ön nihai şalter etkin (açık) Alt satır: P=00. Şu anki kabin konumu. Bu durumda kat 0. D=02. Hedef. Bu durumda kat 2. (B) DESTINATION 12/06 09:30 • =0 Gösterge (Β). Üst satır: Hedef kat 0 Alt satır: Hata kaydının tarih ve zamanı (Ã) A FD P= 28 D= 03 • EM Gösterge (C). Üst satır: A. Anakartın A röleleri etkin, buna göre yüksek hız (Mekanik VVVF). FD. Aşağı yön etkin EM. Üst ön nihai şalter etkin (açık) Alt satır: P=28. Şu anki kabin konumu. Bu durumda kat 28. D=03. Hedef. Bu durumda kat 3. (Ä) DESTINATION 12/06 09:15 • =3 Gösterge (D). Üst satır: Hedef kat 3 Alt satır: Hata kaydının tarih ve zamanı KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-42- 5.2 Hata listesi Seri haberleşmeli kumada panosunun hataları, muhtemel nedenleri ve asansörü normal çalışmaya döndürecek bazı düzeltici eylemlerle birlikte aşağıdaki tabloda anlatılmıştır. Hata 01 MAN AND INS ACTIVE TOGETHER 02 OIL PTC ACTIVATED 03 MOTOR PTC ACTIVATED 06 OVERLOAD ACTIVATED Açıklama – Muhtemel neden Pano revizyonu (MAN) ve kabin revizyonu (INS) aynı anda açık. Yağ termistörü açık (MTH) {Hidrolik Asansör}. Yağ sıcaklığı normale düşünce normal çalışmaya dönecektir. Motor termistörü açık (STH) {Hidrolik & Mekanik Asansör}. Motor sıcaklığı normale düşünce normal çalışmaya dönecektir. Bu hata Flexy Lift modelinde otomatik katlanır etek sacının çalışmasındaki bir problemi ifade edebilir. Etek sacı yarım açılmış veya açılmaması gereken yerde tamamen açılmış olabilir. Aşırı yük etkin (SUI). Asansörün otomatik olarak normal çalışmaya dönmesi için kabindeki fazla yük çıkarılmalıdır. 07 SAFETIES OPEN POINT -1Β- Emniyet devresi nokta 1B’de kesintiye uğradı 08 SAFETIES OPEN POINT -6- Emniyet devresi nokta 6’da kesintiye uğradı 09 SAFETIES OPEN POINT -8- Emniyet devresi nokta 8’de kesintiye uğradı 10 SAFETIES OPEN POINT –8A- Emniyet devresi nokta 8A’da kesintiye uğradı 11 SAFETIES OPEN POINT -10-- Emniyet devresi nokta 10’da kesintiye uğradı 12 NO DOOR ZONE WHILE RELEVELING Tüp manyetikler (CAZA, CAZB) düzgün ayarlanmamış (ya eş zamanlı değil ya da hiç yerleştirilmemiş) {Hidrolik & Mekanik asansör} 15 POWER RELAY STILL ACTIVE Güç kontaktörleri hareket (FPR) sonunda devre dışı olmuyor. { Mekanik asansör } 16 POWER RELAY DIDN’T ACTIVE Güç kontaktörleri hareket (FPR) başlangıcında çalışmıyor. { Mekanik asansör} 17 POWER RELAY OFF WHILE MOTION 19 FIREMAN ACTIVATED KILAVUZ: SERİ HAB. Güç kontaktörleri hareket (FPR) esnasında bırakıyor. Yangın ihbarı devrede (FIR) http://www.kleemannlifts.com.tr Kontroller – Düzeltici eylemler Lütfen birini veya normal çalışmaya geçiş için ikisini kapatın. Ayrıca termistörü kontrol edin. • Motor termistörünü kontrol edin • Etek sacının çalışmasını kontrol edin (Flexy). Yük kapasiteden fazla değilse elektronik aygıtın doğru programlandığından emin olun. Devre şemasını kullanarak emniyet devresi nokta 1B’den önce hangi emniyet aygıtının etkin olduğunu kontrol edin. Devre şemasını kullanarak emniyet devresi nokta 1B ve 6 arasında hangi emniyet aygıtının etkin olduğunu kontrol edin. • Otomatik kapı. Kabin kapısı kontağı • Kramer kapı – yarı otomatik kat kapısı. Kramer kapı kontağı. • Otomatik kapı. Nokta 8A ile nokta 6 fabrika çıkışı köprülüdür (ör. bu durumda kullanılmıyor) • Kramer kapı – yarı otomatik kat kapısı. Kat kapısı kontağı • Otomatik kapı. Kat kapısı kontağı. • Kramer kapı – yarı otomatik kat kapısı. Kat kapısı kilit kontağı. • Mıknatısları hizalayın • Tüp manyetikleri kontrol edin • Güç kontaktörlerini veya yedek kontaklarını kontrol edin VVVF çalışma durumunda güç kontaktörlerinin kapatma zamanlayıcısının ayarını kontrol edin. “Seyir bilgisi parametreleri” menüsünde “HAREKET SONU GECİKME AYARI” değerinden az olmalıdır. • Güç kontaktörlerini veya yedek kontaklarını kontrol edin • Güç kontaktörlerini veya yedek kontaklarını kontrol edin • Emniyet devresinin hareket esnasında kesintiye uğrayıp uğramadığını kontrol edin (ör. kapı kilitleri) FIR girişi devre dışı olduğunda normal çalışmaya dönecektir. Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Hata 21 CAR PRIORITY ACTIVE Açıklama – Muhtemel neden Tam yük devrede (FLI) Kabin izin verilen maksimum ağırlık ile yüklendi. Tam yük devrede olduğu sürece kat çağrıları kaydedilmeyecek veya alınmayacaktır. 26 ED OPEN Kabin hareketsiz Alt ön nihai şalter kontağı yanlış zamanda açtı. 27 EM OPEN Kabin hareketsiz Üst ön nihai şalter kontağı yanlış zamanda açtı 28 ED CLOSED Kabin hareketsiz Alt ön nihai şalter kontağı yanlış zamanda kapattı. 29 EM CLOSED Kabin hareketsiz Üst ön nihai şalter kontağı yanlış zamanda kapattı. 30 ED/EM ACTIVE TOGETHER İki nihai şalter aynı zamanda açtı (ΕΜ / ΕD) 36 TRAVEL TIMER Yüksek hız zamanlayıcısı açık Sayfa-43- Kontroller – Düzeltici eylemler • Yük doğru değilse elektronik aygıtın doğru programlandığından emin olun. • Şalterin düzgün çalışmasını ve konumunu kontrol edin • Tüp manyetiklerin çalışmasını kontrol edin CAA, CAB. • Ayrıntılı bilgi için hata kayıtlarını kontrol edin. • Şalterin düzgün çalışmasını ve konumunu kontrol edin • Tüp manyetiklerin çalışmasını kontrol edin CAA, CAB. • Ayrıntılı bilgi için hata kayıtlarını kontrol edin. • Şalterin düzgün çalışmasını ve konumunu kontrol edin • Tüp manyetiklerin çalışmasını kontrol edin CAA, CAB. • Ayrıntılı bilgi için hata kayıtlarını kontrol edin. • Şalterin düzgün çalışmasını ve konumunu kontrol edin • Tüp manyetiklerin çalışmasını kontrol edin CAA, CAB. • Ayrıntılı bilgi için hata kayıtlarını kontrol edin. Her iki şalterin çalışmasını kontrol edin. • Valf bloğu çalışmasını kontrol edin ‘GENERAL TIMERS’ menüsünde ‘TRAVEL TIMER HIGH SPEED’ zamanlayıcısını artırın • Valf bloğu çalışmasını kontrol edin ‘GENERAL TIMERS’ menüsünde ‘TRAVEL TIMER SLOW SPEED’ zamanlayıcısını artırın 38 TRAVEL TIMER SLOW SPEED Düşük hız zamanlayıcısı açık 40 RELEVELING DIRECTION UP Yukarı yön seviyeleme esnasında kabin kapı seviyesinin dışına çıktı. • Mıknatıs dizilimini kontrol edin • Yağ sıcaklığını kontrol edin • Tüp manyetiklerin çalışmasını kontrol edin 41 RELEVELING DIRECTION DOWN Aşağı yön seviyeleme esnasında kabin kapı seviyesinin dışına çıktı. • Mıknatıs dizilimini kontrol edin • Yağ sıcaklığını kontrol edin • Tüp manyetiklerin çalışmasını kontrol edin KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011 Asansörde 1. Tercihiniz KOMPLE ASANSÖR SİSTEMLERİ SERİ HABERLEŞMELİ KUMANDA PANOSU & HAZIR TESİSAT MONTAJ KILAVUZU Sayfa-44- EK Α. ΕΝ81.2 + Α3 1.UCM Hataları Aşağıdaki tabloda yer alan hatalar hidrolik sistemdeki muhtemel ciddi hasarlarla ilgilidir. Emniyet konusunun öneminden dolayı bu hatalar kumanda panosunun kalıcı kilitlenmesine yol açar. Bu da hatanın giderilmesi için revizyonun etkinleştirilip devre dışı bırakılmasından ziyade ekstra kontrol gerektirir. UCM hatasının giderilmesi için hidrolik sistemin eksiksiz kontrolünün ardından SL-MAIN kartı göstergesinin altında yer alan 4 yön okuna [ (1) Sol, (2) Sağ, (3) Yukarı, (4) Aşağı] eş zamanlı basılmalıdır. Hata 61 POWER RELAY STILL ACTIVE UCM 62 UCM ZONE FAILURE DURING RELEVEL. 65 UCM DOWN VALVE 66 UCM L10 67 UCM ZONE FAILURE 68 UCM DOOR ERROR 6B UCM L10 FPR MONITOR 6C UCM DOWN VALVE FPR MONIT. 6D UCM TEST INTERRUPTED Açıklama – Muhtemel neden Kontroller – Düzeltici eylemler Ana kontaktörler seyir sonunda devre dışı bırakılmadı. A3 fonksiyonlarının etkinleştirilmesiyle hata 15 kalıcı olan hata 61’e dönüştürüldü. Sistem yetkili personel tarafından kontrol edilmelidir. Ana ve yardımcı kontaktörleri kontrol edin. Ayrıca emniyet valfi rölesini de (RCL) kontrol edin. (RCL) Asansör seviyeleme işlemi esnasında kat seviyesinden çıktı. • Tüp manyetikleri kontrol edin • Seviyeleme kartını kontrol edin • Valf bloğunu muhtemel kaçağa karşı kontrol edin Kumanda panosu aşağı yön valfini denetleme testi esnasında hareket algıladı. Valf bloğunu ve emniyet valfini muhtemel kaçağa karşı kontrol edin. Kumanda panosu emniyet valfini denetleme testi esnasında hareket algıladı. Valf bloğunu ve emniyet valfini muhtemel kaçağa karşı kontrol edin.. Asansör bir katta boşta beklerken panodan hareket sinyali almadan kat seviyesinden çıktı. Valf bloğunu muhtemel kaçağa karşı kontrol edin Kendini denetleme testi esnasında kapı kapanamadı. • Kapıların çalışmasını kontrol edin • Kapı emniyet devrelerini (8-10) kontrol edin. Kendini denetleme testi esnasında emniyet valfi rölesi (RCL) panodan devre dışı bırakılmasına rağmen yapışık kaldı. Emniyet valfi rölesinin (RCL) çalışmasını kontrol edin. Kendini denetleme testi esnasında aşağı yön valfi rölesi (RD) panodan devre dışı bırakılmasına rağmen yapışık kaldı. Aşağı yön valfi rölesinin (RD) çalışmasını kontrol edin. Kendini denetleme testi yarıda kesildi Kendini denetleme testi sadece emniyet devresi hatasında yarıda kesilebilir. Emniyet devresinin kesildiği net noktayı bulmak için lütfen hata menüsüne dönün. Kendini denetleme testi yarıda kesildikten sonra sistemin çalışmasını kontrol edin ve ayrıca valf bloğunu herhangi bir yağ kaçağına karşı kontrol edin. Kendini denetleme testi kumanda panosunun saatinin 23:59’a ayarlanmasıyla programlanır. Saat 00:00 olduğunda test başlar. Testin tamamlanmasının ardından saati gerçek zamana ayarlayın. 2.Hidrolik sistemin kendini denetlemesi Her 24 saatte bir kumanda panosu aşağı yön valfleri ve emniyet valflerinin çalışmasını kontrol eder. Asansör otomatik olarak en alt kata hareket eder, kapılar kapanır ve valfler ard arda kontrol edilir. Her bir valfe belirli bir süre enerji verilir. CAB sinyalinin etkinleşmesi durumunda kumanda panosu kaçak algılanmasından dolayı sistemi kilitler. Kumanda panosu sadece sistemin yetkili personel tarafından kontrolü sonrasında normal çalışmasına döner. KILAVUZ: SERİ HAB. http://www.kleemannlifts.com.tr Sürüm 1.2 11/2011