model lv13l brass balanced pressure thermostatic steam trap

Transkript

model lv13l brass balanced pressure thermostatic steam trap
SDS U2012-18
BALANCED PRESSURE
THERMOSTATIC STEAM TRAP
MODEL
LV13L BRASS
BALANCED PRESSURE THERMOSTATIC STEAM TRAP WITH “FAIL OPEN” DESIGN
Features
Balanced pressure thermostatic trap
suitable for small process, tracing,
vessels and heaters.
1. “Fail open” feature will not hold back
condensate in the steam space.
2. Multi-diaphragm construction for long
service life.
3. Cyclic operation with fixed subcooling
throughout entire pressure range.
4. Outstanding air venting capability.
5. Compact, yet high capacity.
6. Easy to maintain and easy to clean.
7. Hardened stainless steel “flat valve” plus
“cone ridge seat” ensure tight shutoff.
8. Built-in screen with large surface area.
Patented
Specifications
Model
Connection
Size
Maximum Operating Pressure (barg)
Minimum Operating Pressure (barg)
Maximum Back Pressure
Maximum Operating Temperature (°C)
Subcooling of X-element Fill (°C)
Type of X-element
LV13L
Screwed
1
⁄ 2”, 3⁄4”
13
0.1
90% of Inlet Pressure
200
up to 6
B
PMO
TMO
PRESSURE SHELL DESIGN CONDITIONS (NOT OPERATING CONDITIONS): Maximum Allowable Pressure (barg) PMA: 16
Maximum Allowable Temperature (°C) TMA: 220
CAUTION
No.
①
②
③R
④R
⑤R
⑥R
⑦R
⑧R
⑨
To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range.
Local regulations may restrict the use of this product to below the conditions quoted.
Description
Body
Cover
Valve Seat
X-element
X-element Guide
Spring Clip
Screen
Cover Gasket
Nameplate
* Equivalent materials
1 bar = 0.1 MPa
Material
Brass C3771
Brass C3771
Stainless Steel SUS420F
Stainless Steel
Stainless Steel SUS304
Stainless Steel SUS304
Stainless Steel SUS304
Fluorine Resin PTFE
Stainless Steel SUS304
Replacement kits available: (R) repair parts
DIN*
2.0380
2.0380
1.4028
—
1.4301
1.4301
1.4301
PTFE
1.4301
ASTM/AISI*
B124 C37700
B124 C37700
AISI420F
—
AISI304
AISI304
AISI304
PTFE
AISI304
Dimensions
¡LV13L
LV13L
Screwed
Size
1
⁄ 2”
3
⁄4”
L
Screwed*
L
64
66
(mm)
φW
H
70
77
A
20
27
52
B
38
40
Weight (kg)
0.5
* BSP DIN 2999, other standards available
W
A
H
B
Discharge Capacity
Discharge Capacity (kg/h)
800
700
500
300
200
100
0.1
0.3
0.5
1
2
Differential Pressure (bar)
3
5
10
13
1 bar = 0.1 MPa
1. Differential pressure is the difference between the inlet and outlet pressure of the trap.
2. Recommended safety factor: at least 2.
SDS U2012-18 Rev. 4/2013
Products for intended use only.
Specifications subject to change without notice.