outdoor sounder - EDS Elektronik

Transkript

outdoor sounder - EDS Elektronik
INSTALLATION MANUAL
AS 270
OUTDOOR SOUNDER
EDS Elektronik Destek
Sanayi ve Ticaret Ltd. Þti.
Meclis Mah. Teraziciler Cad.
Kýlýç Sok. No:4 34785
Sarýgazi/ Ýstanbul
Phone : +90 216 528 45 00
Fax : +90 216 314 17 80
www.eds.com.tr [email protected]
8 8
KK-AS270/0703-1
\\Edsfile\Pazarlama\Kullanim kilavuzu\EDS\INGILIZCE\Harici Siren\AS270_eng.pdf
SERVICE
AS 270
OUTDOOR SOUNDER
AS 270
OUTDOOR SOUNDER
Card Placement
Sounder Trigger
Flasher Trigger
F
FACTORY DEFAULTS
JP 1 :
JP 2:
JP 3:
JP 4:
JP 5:
Negative
Negative
Short
Open
Open
12VDC
-
+
Battery
P
Fonksiyon
Jumper
Kapalý
Açýk
N
Siren Süresi
JP 3
5 dak.
15 dak.
P
Flaþör Tetikleme Tipi JP 1
Siren Tetikleme Tipi
AS 270
13.6VDC
38mA
250-380mA
102-108dB
2.0-4Khz
4 selectable
5min or 15min selectable
Single Piezo
Negative / positive
Negative / positive
1000.000
4/sec.
Red
Running LED
Available
Outdoor
Alarm Panels
ABS Plastic
White
210x320x80
920gr
-10°C ~ +50°C
+
N
Techinical Specifications
Model
Operating voltage
Stand-by current
Alarm current
Voice output
Voice frequency
Sound type
Siren time
Buzzer
Trigger type
Flasher trigger
Flasher life time
Flasher frequency
Beacons
Stand-by LED display
Tamper
Environment
Application
Housing
Colors of housing
Dimensions
Weight
Operating temperature
Mikro
switch
Tamper
+12V- S
The piezo buzzer with extremely high sound level capacity used for AS 270 series sounders. AS 270 Series
Sounders are controlled by microprocessor.
Figure 5
SAB
AS 270 Series Outdoor Sounders are aesthetically designed, high quality sounders for outdoor usage.
These products are compatible with all security systems and also durable for any kind of weather
conditions and impact.
Sounders are protected with outer plastic material cover and also inner metal cover is optional.
AS 270 Series Sounders are compatible with all alarm panels and interior tamper key which is used for the
tamper and system disorders and also running LED display is available.
Buzzer
General
JP 2
Short
JP 2
JP 3
JP 4
JP 5
JP 1
N: Negatif Tetikleme
P: Pozitif Tetikleme
N: Negatif Tetikleme
P: Pozitif Tetikleme
Function
Jumper
Sounder time
JP 3
Flasher trigger type
JP 1
N: Negative trigger
P: Positive trigger
JP 4
JP 5
Sounder trigger type JP 2
N: Negative trigger
P: Positive trigger
X
X
1. Sound
X
-
2. Sound
-
X
3. Sound
-
-
4. Sound
5 min.
Open
15 min.
X : Open
- : Short
Sound no
Warning & Cautions
• Please read the manual before attempting installation or operation.
• Do not keep close a fire to the battery.
• Do not reverse charge.
• Do not short-circuit.
Optional Accessory
Battery
Inner cover
Piezo
2 8
• For the perfect sound performance please keep the surface as smooth as possible.
1.2Ah ViCd
Galvanized
2. Piezo
• When occurs any problem on the sounder, turn off the power immediately and contact the
technical service.
78
AS 270
OUTDOOR SOUNDER
AS 270
OUTDOOR SOUNDER
Sample Panel Connections
Mount
S- S+
FL SI - 12V + SAB
Siren Trigger
Flasher Trigger
S- S+
+SİRENPOS COM AUX1
Siren Trigger
Flasher Trigger
Siren Trigger
Flasher Trigger
-12 V +
FL SI - 12V + SAB
Opening The Top Cover After Mounting
CADDX NX-4/6/8
FL SI - 12V + SAB
Siren Trigger
Flasher Trigger
Siren Trigger
Flasher Trigger
* 46 # 1 * * * EXIT
After completing the electricity and battery connections, place the transparent protection cover as
shown on Figure 4.
FL SI - 12V + SAB
GENERAL
Flasher
trigger
(Prg. input)
(Location(Menu) NO)
(Prg. Output options)
(outrput active 0-.255min.)
(Prg. Output)
3- Place the battery to the slot shown in Figure 2. Be careful the polarities and the direction of the battery
for the cable connection. Fix the battery with the cable bound.
Attaching the Top Cover
Siren
trigger
*897130#
47 #
7*
max.0 - 255dk
2-Set the electricity connections of the card as shown in Electricity Connections/Figure 5 and draw
attention to the sample Panel Connection section.
PREMIER 412/816
1 2
Siren Trigger
Flasher Trigger
S
CLASSIC
Opening The Top Cover Before Mounting
1- Mark the screw holes and suspender places on the wall with the aid of box bottom plastic or template
on the package for mounting as shown Figure 1.
FL SI - 12V + SAB
FL SI - 12V + SAB
CADDX NX 4/6/8 AUX1 programmer:
VERÝTAS 8/8R
S D C B A
S
ST8048
As shown on Figure 4 push the ‘M’ latch with a straight screw driver to upwards and lift the top cover.
Again push the top cover upwards to let the ‘A’ nails release and remove the top cover.
Important Mounting Notes
1- It should be at least 5 cm below the ceiling in order to be able to open the top cover during assembly.
2- Choose a clean and smooth surface for easy mounting.
3- Use 4 units of M4*52 metal screw and M8 plastic screw holder in-wall.
Figure 5
6 8
38
AS 270
OUTDOOR SOUNDER
AS 270
OUTDOOR SOUNDER
Mount
Mount
Figure 1
Figure 3
Suspender
Screw
Screw
Cable
Entry
Screw
Screw
Figure 2
Figure 4
Battery
4 8
58

Benzer belgeler