model gt10l cast iron cast steel

Transkript

model gt10l cast iron cast steel
SDS U2404-06
MODEL
IRON
GT10L CAST
CAST STEEL
COMPACT MECHANICAL PUMP WITH STEAM TRAP FOR CONDENSATE REMOVAL AND RECOVERY
Features
Pump/trap with built-in steam trap for a wide range
of applications: drainage of low capacity heat
exchangers, flash steam recovery systems and
reservoirs, often operating under vacuum
conditions.
1. Handles high temperature condensate without
cavitation.
2. No electric power or additional level controls
required, hence INTRINSICALLY SAFE.
3. Pump will operate with a low filling head
(min. 300 mm).
4. Easy, inline access to internal parts simplifies
cleaning and reduces maintenance costs.
5. High quality stainless steel internals and hardened
working surfaces ensure reliability.
6. Compact design permits installation in a limited space.
Specifications
Model
GT10L
Pumped Medium Inlet & Outlet
Motive Medium & Pump Exhaust
Pumped Medium: Inlet × Outlet
Motive Medium Inlet
Size (mm)
Pump Exhaust Outlet
Maximum Operating Pressure (barg)
PMO
Maximum Operating Temperature (°C)
TMO
Motive Medium Pressure Range (barg)
Maximum Allowable Back Pressure
Volume of Each Discharge Cycle (R)
Motive Medium**
Pumped Medium***
Connection
Screwed and Flanged*
Screwed
Screwed
11⁄2” × 1”
⁄”
1⁄2”
10.5
185
0.3 – 10.5
0.5 bar less than motive medium pressure used
approximately 6
Saturated Steam
Steam Condensate
1”/ DN 25 × 1”/ DN 25
12
* For details of flange connection, see picture at bottom right ** Do not use with toxic, flammable or otherwise hazardous fluids.
*** Do not use for fluids with specific gravities under 0.85 or over 1, or for toxic, flammable or otherwise hazardous fluids.
1 bar = 0.1 MPa
PRESSURE SHELL DESIGN CONDITIONS (NOT OPERATING CONDITIONS):
Maximum Allowable Pressure (barg) PMA: 13 (Cast Iron), 21 (Cast Steel)
Maximum Allowable Temperature (°C) TMA: 200 (Cast Iron), 220 (Cast Steel)
CAUTION
No.
q
w
e
r
t
y
u
i
o
!0
To avoid abnormal operation, accidents or serious injury, DO NOT use
this product outside of the specification range. Local regulations may
restrict the use of this product to below the conditions quoted.
Description
Material
Cast Iron FC250
Body
Cast Steel** A216 Gr.WCB
Cast Iron FC250
Cover
Cast Steel** A216 Gr.WCB
Cover Gasket
Graphite Compound
Float
Stainless Steel SUS316L/304
Snap-action Unit
Stainless Steel
Intake Valve
Stainless Steel SUS440C
Motive Medium Intake
Valve Unit
Valve Seat
Stainless Steel SUS420F
Exhaust Valve Stainless Steel SUS440C
Exhaust Valve Unit
Valve Seat
Stainless Steel SUS420F
Steam Trap Unit
Stainless Steel
Cast Stainless Steel A351 Gr.CF8
Screwed CK3MG***
Inlet
Check Valve Flanged CKF5M
Stainless Steel SUS304
Cast Stainless Steel A351 Gr.CF8
Screwed CK3MG***
Outlet
Check Valve Flanged CKF3M
Cast Stainless Steel A351 Gr.CF8
* Equivalent materials ** Option: Cast Stainless Steel *** Not shown
DIN*
0.6025
1.0619
0.6025
1.0619
—
1.4404/1.4301
—
1.4125
1.4028
1.4125
1.4028
—
1.4312
1.4301
1.4312
1.4312
ASTM/AISI*
A126 Cl.B
—
A126 Cl.B
—
—
AISI316L/304
—
AISI440C
AISI420F
AISI440C
AISI420F
—
—
AISI304
—
—
Flange Connection (25 mm)
Discharge Capacity
1200
¡CORRECTION FACTOR
Motive Medium: Saturated Steam
Motive Steam Pressure: barg
Condensate Temperature: 90 °C
For discharge capacity graph A
with filling head other than 630 mm
(minimum filling head: 450 mm)
1000
1400
1300
800
Filling Head (mm)
Screwed
1”
1”
CK3MG
1”
1”
630 mm
Discharge Capacity (kg/h)
Connection:
Inlet size:
Outlet size:
Check Valve:
Inlet:
Outlet:
Filling Head:
1.5
600
2
3
4
400
10
6
0
1
2
3
4
5
8
6
7
System Back Pressure (barg)
9
1100
1.5
2
700
400
10
8
4
6
0
1
2
3
4
5
6
7
System Back Pressure (barg)
8
9
1 bar = 0.1 MPa
1100
630 mm
1.0
1.5
1200
1100
1000
900
800
700
630
500
450
0.6
1.0
1.5
¡CORRECTION FACTOR
Motive Medium: Saturated Steam
Motive Steam Pressure: barg
Condensate Temperature: 90 °C
1000
Discharge Capacity (kg/h)
Filling Head:
700
630
1300
900
500
Connection: Flanged
Inlet size:
DN 25
Outlet size: DN 25
Check Valve:
Inlet (CKF5M): DN 25
Outlet (CKF3M): DN 25
800
1400
3
C
900
For discharge capacity graph B
with filling head other than 630 mm
(minimum filling head: 450 mm)
1300
Filling Head (mm)
CK3MG
11⁄2”
1”
630 mm
1100
1000
¡CORRECTION FACTOR
Motive Medium: Saturated Steam
Motive Steam Pressure: barg
Condensate Temperature: 90 °C
Discharge Capacity (kg/h)
Connection: Screwed
Inlet size:
11⁄2”
Outlet size: 1”
1200
500
450
0.6
1 bar = 0.1 MPa
1500
B
Check Valve:
Inlet:
Outlet:
Filling Head:
8
For discharge capacity graph C
with filling head other than 630 mm
(minimum filling head: 300 mm)
900
800
1400
1300
700
1200
600
1.5
500
2
3
400
4
10
300
200
6
0
1
2
3
4
5
8
6
7
System Back Pressure (barg)
8
9
1 bar = 0.1 MPa
Filling Head (mm)
A
1100
1000
900
800
700
630
500
400
300
0.6
NOTE:
¡A check valve must be installed at both the pumped medium inlet and
outlet. To achieve the above capacities with the standard GT10L
configuration, either TLV check valves CK3MG (inlet & outlet), or
CKF5M (inlet) and CKF3M (outlet) must be used. depending on
connection type.
¡Motive medium pressure minus back pressure must be greater than
0.5 bar.
¡In closed system applications, the motive medium must be compatible
with the liquid being pumped. If a non-condensable gas such as air or
nitrogen is used as the motive medium, consult TLV for assistance.
¡A strainer must be installed at the motive medium and pumped
medium inlets.
1.0
1.5
¡FILLING HEAD AND PRESSURES
The discharge capacity is
determined by the motive medium,
motive medium pressure (Pm) and
back pressure (P2).
P1
Condensate Reservoir
Pm
P2
GT10L
Filling
Head
Make sure that:
Discharge Capacity × Correction Factor
> Required Flow Rate
SDS U2404-06
Dimensions
360
Units: mm
250
16
352
237
300
375
410
16
Motive Medium Inlet
BSP 1⁄2
Note: All Plug Holes BSP
107
Pump Exhaust
Outlet BSP 1⁄2
The reservoir must have a capacity sufficient to store the
condensate produced during the PowerTrap operation and
discharge.
Pumped Medium Outlet
BSP 1/DN 25 PN 10, 16, 25*, 40*
Weight (kg)
Cast Iron
Cast Steel
* Cast steel only
1⁄2
Size of Reservoir
Pumped Medium Inlet
BSP 1/DN 25 PN 10, 16, 25*, 40*
or BSP 11⁄2
46
50
Steam Consumption
(Motive Medium)
6
Amount of
Condensate
kg/h
300 or less
400
500
600
800
1000
1500
2000
3000
4000
5000
6000
7000
8000
9000
10000
Reservoir diameter (mm) and length (m)
40
1.2 m
1.5
2.0
50
0.7
1.0
1.2
1.5
2.0
80
0.5
0.6
0.8
1.0
1.5
2.0
100
0.5
0.7
1.0
1.3
2.0
150
200
0.6
0.9
1.2
1.4
1.7
2.0
250
0.5
0.7
0.8
1.0
1.2
1.3
1.5
1.7
(per 1 tonne condensate)
Size of Reservoir; flash steam is not involved
Steam Consumption (kg)
5
4
3
2
1.7
1
0.5
0.6
0.7
0.8
0.9
1.0
1
2
3
4
5
Back Pressure (barg)
6 7 8 9 10
1 bar = 0.1 MPa
Reservoir length can be reduced by 50% when the motive pressure (Pm)
divided by the back pressure (P2) equals 2 or greater (when Pm ÷ P2 ≧ 2).
GT10L Steam Trap Discharge Capacity
Discharge Capacity (kg/h)
20000
10000
7000
5000
3000
2000
: Capacity of GT10L as a steam trap (P1 > P2).
Instantaneous condensate loads above the rated trap
capacity will cause the pump to cycle and therefore
reduce the discharge capacity.
: Minimum amount of condensate required to prevent
steam leakage.
1000
700
500
300
200
100
70
50
30
0.1
1. Capacities are based on continuous discharge of condensate
6 °C below steam temperature.
2. Differential pressure is the difference between inlet and outlet
pressure of the trap.
0.5
1
2
3
5
7
10
10.5
1 bar = 0.1 MPa
Differential Pressure (bar)
CAUTION
DO NOT use this product under conditions that
exceed maximum differential pressure, as
condensate backup will occur!
SDS U2404-06
Memo:
SDS U2404-06 Rev. 9/2015
Products for intended use only.
Specifications subject to change without notice.

Benzer belgeler

Specifications

Specifications Pump/ Trap with built-in steam trap for a wide range of applications: drainage of heat exchangers, flash steam recovery systems and non-vented receivers such as low-pressure stages of turbines and ...

Detaylı

Specifications

Specifications Motive Steam Pressure: barg Condensate Temperature: 90 °C

Detaylı

model gp10f cast steel carbon steel

model gp10f cast steel carbon steel receivers and sump drainage. 1. Handles high-temperature condensate without cavitation. 2. No electric power or additional level controls required, hence INTRINSICALLY SAFE. 3. Pump will operate wi...

Detaylı

steam trap

steam trap 7. Hardened working surfaces for long life.

Detaylı

steam trap

steam trap Maximum Operating Temperature (˚C)

Detaylı

steam trap

steam trap * PRESSURE SHELL DESIGN CONDITIONS (NOT OPERATING CONDITIONS) 1 bar = 0.1 MPa ** This Rating Graph is based on Allowable Stress Values of ASTM-Materials at each temperature.

Detaylı