Yüksek Çıkış Güç Faktörlü Modüler UPS

Transkript

Yüksek Çıkış Güç Faktörlü Modüler UPS
RM Serisi
Modüler UPS
50-500 kVA
Kesintisiz Güç Kaynağı & Data Center Altyapı Çözümleri
Görüntüle
Yüksek Çıkış
Güç Faktörlü
Modüler UPS
RM Serisi ailesine göze çarpan güç faktörü ile yeni bir üye...
Her biri 50 kVA Modüllerden oluşan kapasitesini 1 MVA kadar
arttırılabilen, çift çevrimli, esnek akü konfigürasyonuna sahip,
fonksiyonel kullanımı, yük altında modül değiştirme özelliği ile
kesintisiz çalışma imkanı veren dev bir UPS sistemidir...
42
Technical Specifications
Rated Power / Max. Output Power
Power of Each Module
Max. Number of UPS Modules
RM50-500
50-500 kVA / 50-500 kW
50 kVA
10
GENERAL
UPS Type / Technology
MTBF / MTTR
Output Power Factor
Display Parameteres via LCD
Smart Features / Smart Eco Mode
True Redundancy / [ N+1 ]
Protections
Troubleshooting
Modular Design (Centralized Parallel Architecture) / 3-Level Technology
> 200,000 hrs / < 10 mins.
1
Mimic Diagram for Complete System; Indicators for Battery, Rectifier, Inverter, Bypass, Load Status;
System Information, Data and Instruction, Current Record Window; Monitoring Main Input,
Bypass Input, AC Output Characters, Load Data, Battery Data (Temp, Remaining Time, Capacity, Etc.)
Cold Start; AC Restart; Auto Restart / Standard; User Selectable
N+1 & N+X Paralleling Options / System Capacity up to 1 MVA/1MW
Consistently reliable protection for hardware and software, Sophisticated detection inside the UPS,
Abundant event log for future check
EPO; Battery Charging & Discharging, Maintenance Circuit Breaker, Generator Statur; Bypass Phase Fault,
Fan Fault, Voltage Abnormal Alarms; Manual UPS Shutdown, ETC.
EFFICIENCY
Overall Efficiency
≥95,5% @ 100% Rated Load
Smart Eco Mode Efficiency
≥98,5% @ 100% Rated Load
INPUT
Rated Voltage
360 / 380 / 400 / 415 VAC 3P + N + GND
Voltage Range
204 ~ 305 VAC (load linear decrease to 35%); 305 ~ 485 VAC (full load)
Rated Frequency
50 or 60 Hz
Frequency Range (Selectable)
40 ~ 70 Hz
Power Factor
0.99
THDi
≤ 3%
OUTPUT
Rated Voltage / Voltage Stability
Rated Frequency / Freq. Accuracy
Voltage Distortion (THDv)
Crest Factor
Overload Capability
360 / 380 / 400 / 415 VAC 3P + N + GND / ±1%
50 or 60Hz / ± 0.1%
< 1% (Linear Load), < 5% (Non-Linear Load)
3:1
102% - 125% Transfer to Bypass After 10 Mins; 125% - 150% Transfer to Bypass After 1 Mins;
>150% Transfer to Bypass After 0.5s.
BATTERY
Rated Voltage [DC] / Quantity
Charger Current
± 240VDC ( ±180VDC; 192VDC; 204VDC; 216VDC; 228VDC; 252VDC ) 30; 32; 34; 36; 38; 40; 42 x 12V/9AH
12A (each power module); Optional Super Charger Module (30A)
COMMUNICATION
Advanced Communication
Remote ON/OFF
RS232, RS485, Dry Contacts, SNMP Card, EPO, Generator Interface, LBS (Load Bus Synchronizer)
Remote EPO or SNMP over LAN
ENVIRONMENT
Operating
Recommended Operating
Storage Temperature
Altitute / Relative Humidity
Audible Noise
0ºC to 40ºC
-40ºC to 70ºC
-25ºC to 70ºC
≤ 1000m above sea level; derating power by 1% per 100m between 1000m and 2000m / 0 to 95%, Non-Condensing
< 65dB
STANDARDS
Safety / EMC / LVD / Performance
IEC61000-4-2 (ESD); IEC61000-3 (RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge); EN62040-2
DIMENSIONS & WEIGHT
Module Dimensions (WxDxH) [mm]
Module / UPS Net Weight [kg]
442x655x131
32 / 200
UPS Dimensions (WxDxH) [mm]
600x900x2160
UPS Packing Dimensions (WxDxH)
700x970x2160
NECRON ürün özelliklerinde önceden bilgi vermeksizin güncelleme hakkına sahiptir.
All specification can be updated by NECRON without notification
43