RT 12260

Transkript

RT 12260
RT 12260
(12V26Ah)
RT 12260 is a general purpose battery with 5 years
floating design life , meet with IEC, JIS standard .With
heavy duty grid, thickness plates, special additives, RT
series battery have long and reliable standby service life.
Specification
Cells Per Unit
6
Voltage Per Unit
12
Capacity
26Ah@20hr-rate to 1.75V per cell @25 oC
Weight
Approx. 8.10 Kg
Max. Discharge Current
260 A (5 sec)
Internal Resistance
Approx. 10 mΩ
Operating Temperature Range
Discharge: -20 C ~60 C
Charge: 0 oC~50 oC
Storage: -20 oC~60 oC
Normal Operating Temperature Range
25 oC±5 oC
Float charging Voltage
13.7 to 13.9 VDC/unit Average at 25 oC
Recommended Maximum Charging
Current Limit
7.8 A
Equalization and Cycle Service
14.6 to 14.8 VDC/unit Average at 25 oC
Self Discharge
RITAR batteries can be stored for more than 6 months
at 25 oC. Self-discharge ratio less than 3% per month
at 25 oC. Please charge batteries before using.
Terminal
Faston F3/F13
Constainer Material
A.B.S. (UL94-HB) , Flammability resistance of UL94-V2
can be available upon request.
o
o
Dimensions
Unit: mm
Terminal F13
Dimension: 166(L)×175(W)×125(H)
Terminal F3
Constant Current Discharge Characteristics : A(25 oC)
F.V/Time
5MIN
10MIN
15MIN
30MIN
1HR
2HR
3HR
4HR
5HR
8HR
10HR
20HR
9 .60V
93.35
66.89
48.6 7
29.90
16.90
10.37
6.786
5.616
4.420
3.230
2.731
1.44 4
1 0.0V
90.85
63.65
47.6 7
29.41
16.82
10.30
6.760
5.590
4.394
3.203
2.705
1.41 8
1 0.2V
85.61
61.40
46.9 2
29.15
16.67
10.22
6.708
5.564
4.368
3.177
2.678
1.39 2
1 0.5V
76.88
56.66
44.6 8
28.42
16.51
10.14
6.682
5.512
4.316
3.151
2.652
1.36 5
1 0.8V
69.39
51.67
41.1 8
27.17
16.12
9.958
6.500
5.382
4.238
3.098
2.626
1.33 9
1 1.1V
60.40
46.18
36.9 4
25.45
15.31
9.516
6.214
5.122
4.056
2.967
2.547
1.26 0
Constant Power Discharge Characteristics : W(25 oC)
F.V/Time
9 .60V
5MIN
889.1
10MIN
650 .1
15MIN
478.7
30MIN
337 .4
1HR
193.3
2HR
119.3
3HR
78.31
4HR
64.90
5HR
51 .17
8HR
37.48
10HR
30.71
20HR
16.2 2
1 0.0V
870.9
621 .0
468.7
333 .2
192.3
118.9
78.16
64.74
50 .86
37.32
30.39
16.0 6
1 0.2V
822.1
600 .3
462.4
329 .3
190.9
117.8
77.69
64.43
50 .70
37.00
30.23
15.9 0
1 0.5V
740.3
554 .7
440.9
321 .8
189.1
116.7
77.22
63.96
50 .23
36.69
29.92
15.7 5
1 0.8V
665.9
503 .6
405.1
307 .2
184.4
115.0
75.35
62.24
49 .45
35.90
29.60
15.5 9
1 1.1V
574.8
447 .3
361.7
287 .8
174.7
109.7
71.60
59.28
46 .96
34.64
28.66
14.9 6
All mentioned values are average values.
12V26Ah
RT 12260
Storage characteristic
10
100
8
Capacity (%)
6
Life Expectancy (years)
Supplementary charge required
(Carry out supplementary charge
before use if 100% capacity is
requires)
0℃
4
2
80
10℃
Supplementary charge required
before use.
This supplementary charge will help
to recover the capacity and should
be made as early as possible.
60
20℃
40
30℃
40℃
Supplementary charge may often
fail to recover the capacity.
The battery should never be left
standing till this state is reached
20
0
0
10
20
30
40
4
2
50
6
8
Storage Time (months)
Battery Temperature (℃)
Charge characteristic Curve for standby use
15
7.5
Discharge characteristic Curve
5.0
120
0.24
100
0.20
13
6.5
4.3
12
6.0
4.0
11
5.5
3.7
10
5.0
3.3
Chcrge Voltage
80
① Discharge
100%(0.05CA×20h)
50%(0.05CA×10h)
② Charge
Chcrge Voltage2.275V/C
Charge Current0.1CA
③ Temperature 25℃
60
40
0.16
0.12
0.08
Terminal Voltage (V)
4.7
Charge Current (CA)
7.0
Charge Volume (%)
Charge Voltage(V)
Chcrge Volume
14
Supplementary charge and storage
guidelines
10 12 14 16 18 20 22 24
13
6.5
4.3
12
6.0
4.0
11
5.5
3.7
0.05C
10
5.0
3.3
9
4.5
3.0
0.62C
1C
3C
20
0.04
0
0
0.093C
0.16C
0.35C
Charge Current
9
4.5
3.0
0
2
4
6
8
0.6
1.2
3
6
12
30
1
2
Charge Time(h)
5
10
20
24
Hr
min
10 12 14 16 18 20 24 28
Discharge Time
Capacity Factors With Different Temperature
Battery Type
-20℃
-10℃
0℃
5℃
10℃
20℃
25℃
30℃
40℃
45℃
GEL
6V&12V
Battery
2V
50%
70%
83%
85%
90%
98%
100%
102%
104%
105%
60%
75%
85%
88%
92%
99%
100%
103%
105%
106%
AGM
6V&12V
Battery
2V
46%
66%
76%
83%
90%
98%
100%
103%
107%
109%
55%
70%
80%
85%
92%
99%
100%
104%
108%
110%
Maintenance & Cautions
Discharge Current VS. Discharge Voltage
Final Discharge
Voltage V/cell
1.75V
Discharge
Current (A)
(A)≤0.2C
1.60V
1.70V
Float Service:
※ Every month, recommend inspection every battery voltage.
0.2C<(A)<1.0C
(A)≥1.0C
Charge the batteries at least once every six months,
if they are stored at 25 oC.
Charging Method:
Equalization charge method:
Discharge: 100% rate capacity discharge.
Charge: Max. current 0.3CA, constant voltage 2.4-2.45V/Cell charge 24h.
Constant Voltage
-0.2Cx2h+2.4~2.45V/Cellx24h,Max. Current 0.3CA
Constant Current
-0.2Cx2h+0.1CAx12h
Fast
-0.2Cx2h+0.3CAx4.0h
SHENZHEN RITAR POWER CO.,LTD.
URL:www.ritarpower.com
※ Every three months, recommend equalization charge for one time.
※ Effect of temperature on float charge voltage: -3mV/℃/Cell.
※ Length of service life will be directly affected by the number of discharge
.
cycles, depth of discharge, ambient temperature and charging voltage.
Address: Rm405,Tower C, Huahan Building,Langshan Rd16, Nanshan District, ShenZhen, 518057, China
Tel:+86-755-33981668 Fax:86-755-8347-5180
2008 - Version 1

Benzer belgeler

RT 1290

RT 1290 9.0Ah@20hr-rate to 1.75V per cell @25 oC

Detaylı

RA12-40

RA12-40 RITAR batteries can be stored for more than 6 months at 25 oC. Self-discharge ratio less than 3% per month at 25 oC. Please charge batteries before using.

Detaylı

BP2.3-12 - BB

BP2.3-12 - BB current charging For (with current cycle service restrication)

Detaylı

BP65-12 - PowerStream

BP65-12 - PowerStream Ambient Temperature Charge..........................................................................................................................................................0oC(32oF)~40oC(10...

Detaylı

PERFORMANCE SPECIFICATIONS Maintenance-Free - BB

PERFORMANCE SPECIFICATIONS Maintenance-Free - BB Maximum Discharge Current For 5 sec.(A)...............................................................................................................................120A Maximum Charge Current(A)....

Detaylı

Maintenance-Free Rechargeable Sealed Lead-Acid - BB

Maintenance-Free Rechargeable Sealed Lead-Acid - BB Charging Procedure Temperature Charging compensation Voltage coefficient of O at 20 C voltage (V/cell) charging (mV/ OC/cell)

Detaylı

BP26-12 - BB

BP26-12 - BB Maximum Discharge Current For 5 sec.(A)..............................................................................................................................390A Maximum Charge Current(A).....

Detaylı

BP7.5-12 - BB

BP7.5-12 - BB Maximum Discharge Current For 5 sec.(A)...............................................................................................112.5A Maximum Charge Current(A)..................................

Detaylı

Spec Sheet - House of Batteries

Spec Sheet - House of Batteries current charging For (with current cycle service restriction)

Detaylı

BP8-6V - BB

BP8-6V - BB ※  Effect of temperature on float charge voltage: -3mV/℃/Cell. ※  Length of service life will be directly affected by the number of discharge

Detaylı