(Low-E) + Kuru Hava + Lamine Cam

Transkript

(Low-E) + Kuru Hava + Lamine Cam
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
4 (# 2) - 12 - 33.1, Heat Control Glass (Low-E #2) + Dry Air (100%) +
Laminated glass (Clear Float Glass+Transparent PVB+Clear Float
Sinerji
Glass)
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
Resistance against sudden temperature
changes and temperature differentials
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
NPD
NPD
NPD
NPD
NPD
NPD
NPD - 12 - 2 (B) 2
NPD
4 - 12 - 33.1
32 (-1; -3) dB
1,6 W / (m 2K)
NPD
0,77/0,12/0,11
0,46/0,25/0,18
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
4 (# 2) - 16 - 33.1, Heat Control Glass (Low-E #2) + Dry Air (100%) +
Laminated glass (Clear Float Glass+Transparent PVB+Clear Float
Sinerji
Glass)
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
Resistance against sudden temperature
changes and temperature differentials
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
NPD
NPD
NPD
NPD
NPD
NPD
NPD - 16 - 2 (B) 2
NPD
4 - 16 - 33.1
32 (-1; -3) dB
1,3 W / (m 2K)
NPD
0,77/0,12/0,11
0,46/0,25/0,18
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
6 (# 2) - 12 - 33.1, Heat Control Glass (Low-E #2) + Dry Air (100%) +
Laminated glass (Clear Float Glass+Transparent PVB+Clear Float
Sinerji
Glass)
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
Resistance against sudden temperature
changes and temperature differentials
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
NPD
NPD
NPD
NPD
NPD
NPD
NPD - 12 - 2 (B) 2
NPD
6 - 12 - 33.1
33 (-2; -5) dB
1,6 W / (m 2K)
NPD
0,76/0,11/0,11
0,46/0,22/0,18
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
6 (# 2) - 16 - 33.1, Heat Control Glass (Low-E #2) + Dry Air (100%) +
Laminated glass (Clear Float Glass+Transparent PVB+Clear Float
Sinerji
Glass)
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
Resistance against sudden temperature
changes and temperature differentials
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
NPD
NPD
NPD
NPD
NPD
NPD
NPD - 16 - 2 (B) 2
NPD
6 - 16 - 33.1
33 (-2; -5) dB
1,3 W / (m 2K)
NPD
0,76/0,11/0,11
0,46/0,22/0,18
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
6 (# 2) - 12 - 44.1, Heat Control Glass (Low-E #2) + Dry Air (100%) +
Laminated glass (Clear Float Glass+Transparent PVB+Clear Float
Glass)
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
Resistance against sudden temperature
changes and temperature differentials
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
NPD
NPD
NPD
NPD
NPD
NPD - 12 - P1A
NPD - 12 - 2 (B) 2
NPD
6 - 12 - 44.1
33 (-2; -5) dB
1,6 W / (m 2K)
NPD
0,76/0,11/0,11
0,45/0,22/0,18
08
EN 1279-5
Insulating glass units, intended to be used in buildings and
construction works
6 (# 2) - 16 - 44.1, Heat Control Glass (Low-E #2) + Dry Air (100%) +
Laminated glass (Clear Float Glass+Transparent PVB+Clear Float
Glass)
Characteristics
Resistance to fire
Reaction to fire
External fire behaviour
Bullet resistance
Explosion resistance
Burglar resistance (EN 356)
Pendulum body impact resistance
Resistance against sudden temperature
changes and temperature differentials
Wind, snow, permanent and imposed load
resistance of the glass unit
Direct airborne sound reduction
Thermal properties
U-value (EN 673)
Normal emissivity (EN 12898)
Radiation properties
Light transmission and reflection
Solar energy characteristics
NPD: No Performance Determined
NPD
NPD
NPD
NPD
NPD
NPD - 16 - P1A
NPD - 16 - 2 (B) 2
NPD
6 - 16 - 44.1
33 (-2; -5) dB
1,3 W / (m 2K)
NPD
0,76/0,11/0,11
0,45/0,22/0,18

Benzer belgeler

(MF 171) + +Argon + Lamine Cam

(MF 171) + +Argon + Lamine Cam Insulating glass units, intended to be used in buildings and construction works 6 (# 2) - 12 - 33.1, Thermally Toughened Heat and Solar Control Coating on Helio® Green (MF 270 #2) + Dry Air (%100) ...

Detaylı

Renksiz Float Cam + Şeffaf PVB + Renksiz Float Cam

Renksiz Float Cam + Şeffaf PVB + Renksiz Float Cam Insulating glass units, intended to be used in buildings and construction works 4 - 12 - 33.1, Thermally Toughened Helio® Bronze + Dry Air (%100) + Laminated glass (Clear Float Glass+Transparent PV...

Detaylı