Malzeme Standartları ve Onaylı Ürün Talimatı

Transkript

Malzeme Standartları ve Onaylı Ürün Talimatı
TÜRKSAT UYDU HABERLEŞME KABLO TV VE İŞLETME A.Ş.
KABLO SİSTEMLERİ MALZEME STANDARTLARI VE ONAYLI ÜRÜN
TALİMATI
HAZIRLAYAN
Kablo Sistemleri Altyapı ve İşletme
Direktörlüğü
Doküman No: TAL.507 Rev.Tar/No:
29.04.2016/ 08
ONAYLAYAN
Genel Müdür
Onay Tarihi: 29.04.2016
Revizyon Tarihi: 29.04.2016
İÇİNDEKİLER
SAYFA NO
1. KABLO SİSTEMLERİ ONAYLI ÜRÜN TALİMATI ………………………………………
3-14
2. KABLO SİSTEMLERİ MALZEME TEKNİK ÖZELLİKLERİ …………………………….
14-123
a. AMAÇ ……………………………………………………………………………………………
16
b. KISALTMALAR ……………………………………………………………………………….
16
c. GENEL HUSUSLAR …………………………………………………………………………
16
d. ALTYAPI MALZEMELERİ …………………………………………………………………
17-42
e. FİBER OPTİK KABLO VE AKSESUARLARI …………………………………………
43-75
g. KOAKSİYEL KABLOLAR ……………………………………………………………………
f. TEKNİK ÖZELLİKLER
h. PASİF RF MALZEMELER ………………………………………………………………….
76-79
i. RF KONNEKTÖRLER ……………………………………………………………………….
87-89
j. AKÜ-UPS ……………………………………………………………………………………….
90-92
k. RF YÜKSELTİCİLER ………………………………………………………………………….
93-95
l. PASİF OPTİK ÜRÜNLER …………………………………………………………………..
96-99
n. AKTİF OPTİK ÜRÜNLER …………………………………………………………………..
m.
o. DAĞITIM DOLAPLARI ……………………………………………………………………..
100-106
p. ÇEŞİTLİ MALZEMELER …………………………………………………………………….
118-120
3. MALZEME LİSTESİ VE ÜRÜN KODLARI ………………………………………………….
121-126
80-86
107-117
2 / 126
KABLO SİSTEMLERİ
ONAYLI ÜRÜN TALİMATI
3 / 126
1) AMAÇ: Kablo hizmetlerinde kullanılan malzemelerin yürürlükteki TÜRKSAT Malzeme Standartlarına
uygunluğunun tescili amacıyla işletilecek süreci belirlemektir.
2) KAPSAM: Kablo Hizmetlerinin gerçekleştirilmesi amacıyla kullanılan tüm aktif ve pasif malzemeleri kapsar.
3) TANIMLAR / KISALTMALAR:




Türksat
:Türksat Uydu Haberleşme Kablo TV ve İşletme A.Ş.
Malzeme Sağlayıcı (MS) :Türksat standartlarına uygunluğunun tespiti için gerekli testleri yaptırmak
amacıyla başvuracak olan üretici veya üretici tarafından yetkilendirilmiş firmalar.
İş Ortağı Firma(İOF)
: Kablo Hizmetleri altyapısının kurulması ve kurulan altyapı üzerinden kablo
hizmetlerinin (Teledünya, Uydunet, Analog TV vb.) yürütülmesi (Tesis, İptal, Nakil, Arıza vb.) ile bakım ve
işletme faaliyetlerini (Bakım, Arıza, Proje, Hasar vb.) gerçekleştiren yüklenici ve/veya altyüklenici firmalar.
Gün
: Aksi belirtilmediği sürece takvim günüdür.
4) İLGİLİ BELGELER (Standartlar, Formlar, Kuruluşlar):












Onaya açılacak ürünler ve özellikleri listesi
TS (Türk Standartları)
EN (European Standards)
ISO (International Organization for Standardization)
IEC (International Electrotechnical Commission)
ITU (International Telecommunication Union)
SCTE (The Society of Cable Telecommunications Engineers)
Kablo Sistemleri Ürün Onay Başvuru Formu (Ek-1)
Kablo Sistemleri Ürün Onay/Red Formu (Ek-2)
Kablo Sistemleri İçin Onaylı Ürün Belgesi (Ek-3)
Ürün Tanıma Belgesi (Ek-4)
Taahhütname (Ek-5)
5) GENEL HUSUSLAR:
a)
MS tarafından, bu esasların tüm maddelerinin kabul edildiğine dair her bir sayfası yetkili kişilerce kaşelenerek
imzalanacaktır.
b)
Bir ürünün Türksat şebekesinde kullanılabilmesi için hem ürüne onay verilmiş hem de MS nin onaylı ürün
sağlayıcı listesine alınmış olması şarttır.
c)
Onay alınmış ürün ile ilgili üretici firma başka bir MS ‘ye yetki vermesi ya da mevcut MS’yi değiştirmesi
durumlarında ilgili MS; bu şartnameye ait 6.b, 6.d, 6.f ve 6.i maddelerinin gereklerini yerine getirdikten sonra
“Onaylı Ürün Sağlayıcı” listesine dahil edilir.
d)
Yapılan başvurunun KABUL’ü ya da RED’di durumlarında “Başvuru ücreti” hiçbir suretle iade edilmez.
e)
MS’nın 7.b, 8.a ve 8.b maddelerinde belirlenen sürelere uymaması durumunda ilgili başvuru Türksat tarafından
iptal edilir. MS’nin talebi halinde Türksat isterse bu sürelere ek süre verebilir.
f)
Türksat gözetiminde yerinde (yurtiçi/yurtdışı) yapılacak testler için her türlü maliyet MS tarafından
karşılanacaktır. Bu süreçte Türksat’tan hiçbir ad altında ücret talep edilmeyecektir. Bununla birlikte maksimum
3 (üç) Türksat personeli için ulaşım ve konaklama giderler MS tarafından karşılanacaktır.
g)
Onay alınan ürünler için sahada kullanılmaya başlamadan önce Ek-4 de belirlenen formatta ilgili malzeme
üzerine çıkmayacak şekilde “Ürün Tanıma Bilgisi” yerleştirilecektir. Bu uygulamaların olmadığı ürünün
kullanımına izin verilmeyecektir.
h)
MS, Onay aldığı ürün ile ilgili Ek-5 de verilen taahhüt belgesini imzalayarak Türksat’a teslim edecektir.
4 / 126
6) BAŞVURU: MS, onay almak istediği ürün/ürünler için aşağıdaki belgeler ile Türksat’a başvuruda bulunur.
a)
Kablo Sistemleri Ürün Onay Başvuru Formu (Ek-1)
b)
Başvuru yapmaya yetkili olduğunu gösteren İmza Beyannamesi veya İmza Sirküleri;
1- Gerçek kişi olması halinde, noter tasdikli imza beyannamesi
2- Tüzel kişi olması halinde, başvuruda bulunma tarihi itibariyle en son durumu gösteren, şirket
ortaklarının hisse durumlarını ve şirketteki görevlerini belirten Ticaret Sicil Gazetesi aslı veya noter tasdikli
sureti ile tüzel kişiliğin noter tasdikli imza sirküleri,
c)
Başvuru yapılan ürünün data sheetleri (CD-Soft kopya)
d)
Distribütörlük belgesi veya yetkili satıcı olduğuna dair belge (Üretici harici başvurular).
e)
Yerli üretimler için alınmış ise TSE belgesi.
f)
Mevzuatı gereği kayıtlı olduğu Ticaret ve/veya Sanayi Odası Belgesi veya ilgili Meslek Odası Belgesi; (Gerçek ve
tüzel kişiler)
g)
Ürüne/ürünlere ait her bir özelliğin hangi test standartlarına göre (madde numaraları, ölçüm metodu
çizelgelerini belirten) test edileceğini gösteren tablolar. (Test için uluslararası tanımlanmış her hangi bir
standart bulunmayan özelliklerin tespitinde kullanılacak yöntem ayrıca detaylarıyla belirtilecektir.)
h)
Onay alınmamış ürünler için Üretici Markası başına 1.000 TL değerinde başvuru ücreti,
i)
Daha önce onay alınmış ürünler için Üretici Markası başına 10.000 TL değerinde başvuru ücreti,
j)
Başvuru yapılan ürünlerin hangi operatörlerde kullanıldığına dair referans listesi,
k)
Ürünlere ait CE belgeleri.
7) BAŞVURUNUN DEĞERLENDİRİLMESİ:
a)
Türksat, ilgili başvuru için gerekli incelemeleri yapar ve 6.g maddesinde belirtilen test prosedürlerinde MS ile
mutabık kalır. Başvuru aşamasını geçen ürünün/ürünlerin listesini (EK-2) kaşeli imzalı olarak MS’ye elden teslim
eder.
b)
MS, her ürün için 6.g maddesine göre yapılmış test sonuçlarını gösterir üretici veya ilgili laboratuvar onaylı
raporları 20 gün içerisinde Türksat’a teslim eder. (CD-Soft kopya)
c)
Türksat, teslim edilen test raporlarını inceler ve her hangi bir eksik ya da problem görmemesi halinde test
raporları içerisinden kendi gözetiminde yapılacak testleri seçerek MS’ye teslim eder.
d)
Bununla birlikte Türksat teslim edilen test raporlarını incelediğinde ürünlerden bir ya da birkaçında
standartların karşılanmadığını tespit ederse ilgili ürünü başvuru listesinden çıkarır.
8) TEST YERİ VE ZAMANININ BELİRLENMESİ (TAKVİM):
a)
MS, başvuru aşamasını geçen ürünün/ürünlerin listesini teslim aldıktan sonra 7 gün içinde madde 7.c
kapsamında belirlenen tüm testler için; testleri nerede ve ne zaman yapılacağını belirtir şekilde bir takvim
hazırlayarak Türksat’a e-mail yoluyla bildirir.
b)
Türksat, verilen takvimi inceledikten sonra değişiklik talebi yoksa takvimi onaylayarak MS’ye e-mail ile bildirir.
Türksat takvim incelemesi sonrası tarih ve konum bilgilerinde değişiklik isteyebilir. Bu durumda yeni takvimin
Türksat’a 7 gün içinde yeniden göndermesi gerekmektedir.
5 / 126
9) TESTLERİN GERÇEKLEŞTİRİLMESİ:
a)
Testler takvimde belirlenen yer ve zamanda Türksat gözetiminde, madde 6.g de mutabık kalınan test
yöntemleri kullanılarak gerçekleştirilecektir.
b)
Test sonuçları, rapor şeklinde hazırlanacak ve testi yapan şirket/kuruluş ile Türksat tarafından imza altına
alınarak bir nüshası Tüksat’a teslim edilecektir.
10) SONUÇLARIN DEĞERLENDİRİLMESİ VE DUYURULMASI:
a)
Türksat teslim aldığı test raporlarını, madde 7.b kapsamında gönderilen raporları ve başvuru evraklarını birlikte
inceleyerek yeterli gördüğü ürüne/ürünlere KULLANILABİLİR ONAYI verecektir.
b)
Bunula birlikte Türksat isterse KULLANILABİLİR ONAYI vermeden önce ürünün/ürünlerin kendi belirleyeceği bir
saha noktasında test edilmesini isteyebilir. Bu durumda ürüne saha testlerinden geçilene kadar ONAY verilmez.
Saha test süresi en az 3 ay olup gerekli görülmesi halinde Türksat tarafından uzatılabilir.
c)
Onay verilen her bir ürün için Türksat “Onay Kodu” belirler. Bu kodlu “Onaylı Ürün Belgesi” (Ek-3) MS’ya teslim
edilir.
d)
En az bir ürünü onaylanan MS onaylı ürün sağlayıcı listesine alınır ve onaylanan ürünler tüm ilgililere (İl
Müdürlükleri, İş Ortakları vb.) duyurulur.
11) ÜRÜN ONAYLARININ YENİLENMESİ :
a)
Bir ürüne ait onay geçerlilik süresi 1 yıl olacaktır. Ürün onay belgesinin süresinin dolmasına 1 ay kala MS talebi ile
yenileme süreci başlatılır.
b) Onaylı Ürün belgesinin yeniden düzenlenmesi için MS tarafından bu talimata ait 6.a, 6.b, 6.d ve 6.f maddelerinde
belirtilen evraklar TÜRKSAT’a teslim edilir.
c) Belge yenilenmesi için Üretici Markası başına 500 TL değerinde ücret yatırılır.
d) Ürün Onaylarının Yenilenmesi için Türksat tarafından bu talimata ait 5.f maddesi uygulanabilir.
12) ÜRÜN ONAYLARININ İPTAL EDİLMESİ ve MALZEME SAĞLAYICININ ONAYLI ÜRÜN LİSTESİNDEN ÇIKARTILMASI
a)
Bir ürüne ait onay geçerlilik süresi 1 yıl olacaktır.
b)
Türksat, Onay alınan ürünler için MS’den veya sahada kullanılan veya İOF deposundan alınan ürünlerden
numuneler seçerek belirleyeceği parametreler için yeniden testler yapabilir ya da yaptırabilir. Testler
sonucunda uygunsuzlukla karşılaşılırsa MS ile birlikte (MS davet edildiği tarihte teste katılmazsa Türksat testleri
tek başına gerçekleştirecektir.) ikinci defa aynı ürünün farklı numuneleri için aynı işlemler uygulanır. İkinci teste
de uygunsuzluk tespit edilirse ürün onayı Türksat tarafından iptal edilir. Bu durumda MS ürün başına 10.000 TL
(onbin türk lirası) ceza ödemeyi kabul eder. Bu ceza 15 gün içerisinde ödenecektir. Süresinde ödenmeyen
cezalar için Türksat gerekli işlemleri başlatır ve uyarıya gerek kalmadan MS onaylı ürün listesinden çıkartılır.
c)
İkinci testin tüm masrafları (test, ulaşım, konaklama) MS tarafından karşılanır.
d)
Uygunsuz ürün tespitinin 3 defadan fazla olması durumunda MS onaylı ürün sağlayıcı listesinden çıkarılır ve 5 yıl
boyunca onaylı ürün sağlayıcı listesine alınmaz.
e)
MS tarafından İOF (İş Ortağı Firmaları) firmalarına onaysız ürün sattığının tespiti halinde, MS ürün başına 50.000
TL (ellibin türk lirası) ceza ödemeyi kabul eder. Bu ceza 15 gün içerisinde ödenecektir. Bu durumun 1 defadan
fazla olması durumunda MS onaylı ürün sağlayıcı listesinden çıkarılır ve 5 yıl boyunca onaylı ürün sağlayıcı
listesine alınmaz. Süresinde ödenmeyen cezalar için Türksat gerekli işlemleri başlatır ve uyarıya gerek kalmadan
MS onaylı ürün listesinden çıkartılır.
6 / 126
f)
Türksat tarafından söz konusu durumlar tüm ilgililere (İlgili MS, İl Müdürlükleri, İş Ortakları vb.) duyurulur.
EKLER:





Ek-1 Kablo Sistemleri Ürün Onay Başvuru Formu
Ek-2 Kablo Sistemleri Ürün Onay/Red Formu
Ek-3 Kablo Sistemleri İçin Onaylı Ürün Belgesi
Ek-4 Ürün Tanıma Belgesi
Ek-5 Taahhütname
7 / 126
EK-1 Kablo Sistemleri Ürün Onay Başvuru Formu (1/3)
FRM.588 Rev. Tar/ No: 25.03.2016/03
SAYFA
KABLO ŞEBEKESİ ÜRÜN
ONAY BAŞVURU FORMU
TAKIP NO
8 / 126
Adı :
Adresi :
Başvuru Sahibi Kuruluş
Üretim Yeri Adı ve Adresi:
(Farklı ise)
Tel
Üretici
Faks
Yetkili Temsilci
E-Posta
Diğer
Vergi Dairesi/ Vergi No:
İrtibat Kurulacak
Teknik Yetkili / Yetkililer
Ürün/Ürünler:
Adı Soyadı:
Görevi :
Tel
Yerli üretim
Faks
E-Posta
İthal ürün
Başvuru Numarası : ………………………………………………………..
(Türksat tarafından verilecektir.)
Onay alınmak için başvuru yapılan ürüne/ürünlere ait tanımlayıcı bilgiler:
NOT:
 Her üretici için farklı başvuru formu kullanılacaktır.
 Başvuru Dökümanları Türkçe olmalıdır.
8 / 126
SIRA
NO
FRM.588 Rev. Tar/ No: 25.03.2016/03
SAYFA
KABLO ŞEBEKESİ ÜRÜN
ONAY BAŞVURU FORMU
TAKIP NO
ÜRÜN TANIMI
MARKA
9 / 126
MODEL/TİP
9 / 126
FRM.588 Rev. Tar/ No: 25.03.2016/03
SAYFA
KABLO ŞEBEKESİ ÜRÜN
ONAY BAŞVURU FORMU
TAKIP NO
10 / 126
Bu formda ve eklerinde (Ayrıca tarafımızca sunulacak ilave dökümanlar da dahil olmak üzere ) verilen bilgilerin doğru olduğunu
beyan ederim.
Adı ve Soyadı:
Görevi:
Tarih :
Kaşe ve yetkili imzası:
BAŞVURU KONTROLÜ
Türksat tarafından doldurulacak.
KONTROL
Ekler
VAR
˟˟1
2
˟˟3
4
˟˟5
6
˟˟7
8
˟˟9
10
YOK
Başvuru yapmaya yetkili olduğunu gösteren İmza Beyannamesi veya İmza Sirküleri;
1- Gerçek kişi olması halinde, noter tasdikli imza beyannamesi
2- Tüzel kişi olması halinde, başvuruda bulunma tarihi itibariyle en son durumu gösteren,
şirket ortaklarının hisse durumlarını ve şirketteki görevlerini belirten Ticaret Sicil Gazetesi aslı veya
noter tasdikli sureti ile tüzel kişiliğin noter tasdikli imza sirküleri,
Başvuru yapılan ürünün data sheetleri (CD-Soft kopya)
Distribütörlük belgesi veya yetkili satıcı olduğuna dair belge (Üretici harici başvurular).
Yerli üretimler için alınmışsa TSE belgesi.
Mevzuat gereği kayıtlı olduğu ticaret ve/veya sanayi odası belgesi veya ilgili meslek odası belgesi.
(Gerçek veya Tüzel kişiler)
Ürüne/ürünlere ait her bir özelliğin hangi test standartlarına göre (madde numaraları, ölçüm metodu
çizelgelerini belirten) test edileceğini gösteren tablolar. (Test için uluslararası tanımlanmış her hangi
bir standart bulunmayan özelliklerin tespitinde kullanılacak yöntem ayrıca detaylarıyla
belirtilecektir.)
Başvuru Ücreti Belgesi
Başvuru yapılan ürünlerin hangi operatörlerde kullanıldığına dair referans listesi,
Taahhütname (EK-5)
CE Belgesi
˟˟Ürün Onaylarının yenilenmesi esnasında istenilen belgeler
TÜRKSAT
Adı Soyadı:
İmza:
Tarih:
Lütfen her sayfayı paraflayınız!
10 / 126
EK-2 Kablo Sistemleri Ürün Onay/Red Formu
FRM.584 Rev. Tar/ No: 28.08.2014/02
KABLO ŞEBEKESİ ÜRÜN
ONAY/RED FORMU
SAYFA
11 / 1
TAKIP NO
Adı :
Adresi :
Üretim Yeri Adı ve Adresi:
(Farklı ise)
Başvuru Sahibi Kuruluş
Tel:
Faks:
E-Posta:
Üretici
Yetkili Temsilci
Diğer
BAŞVURU
Kabul edildi
Red edildi
Başvuru Onay Tarihi/Başvuru Numarası :
SIRA
NO
ÜRÜN TANIMI
MARKA
MODEL/TİP
BAŞVURU ONAY/RED
DURUMU
Başvuruyu Değerlendiren Kişi/Kişilere Ait Bilgiler:
Ad-Soyad
Birim/ Unvan
İşlem Tarihi
İmza
:
:
:
:
11 / 126
EK-3 KABLO SİSTEMLERİ İÇİN ONAYLI ÜRÜN BELGESİ
12 / 126
EK-4
ÜRÜN TANIMA BELGESİ
Ürünlerin tanımlanmasında aşağıdaki bilgiler kullanılacaktır. Her bilgi bir birinden tek boşlukla ayrılacaktır.
a) Onay Kodu: Ürünleri Türksat genelinde tekil olarak tanımlayan en fazla 21 basamaktan oluşan numaradır.
Bu numaranın ilk 10 hanesi ürün tanımı, sonraki 8 hanesi onay tarihi, son 3 hanesi sıra numarasından
oluşmaktadır.
b) Üretici Markası: Onay alan ürüne ait üreticiyi tanımlamak için kullanılan değişken uzunluktaki karakter
dizisidir. Üretici markası birden fazla kelimeden oluşuyorsa arada boşluk bırakmadan yazılacaktır.
c) Ürün Modeli: Onay alan üreticiye ait her ürünü tanımlamak için kullanılan değişken uzunluktaki karakter
dizisidir. Ürün modeli birden fazla kelimeden oluşuyorsa arada boşluk bırakmadan yazılacaktır.
d) Üretim Tarihi: Ürünün üretildiği tarihi tanımlayan 8 basamaktan oluşan numaradır. Format GGAAYYYY
şeklinde olacaktır.
e) Seri Numarası: Onay alan ürünlerin her birini tanımlamak için kullanılan numaradır. Bir ürün için kullanılan
seri numarası, aynı çeşit üründe bir daha kullanılamaz. Seri Numarası değişken uzunlukta olabilecektir.
Aktif cihazlar için yukarıdaki bilgileri içeren “Karekod (QR Code) kullanılacaktır. Karekod, ECC200 standartlarında bir
Datamatrix barkodu olarak, bu standart içinde belirtildiği üzere, kare olarak yerleştirilecektir. Karekodun ürün
üzerine yerleştirilmesi, üretici/malzeme sağlayıcı tarafından yapılacaktır. “Karekod” aşağıdaki gibi olacaktır.
Koaksiyel ve fiber kablolarda ise karekod yerine yukarıdaki bilgiler bir boşlukla kablonun üzerine silinmeyecek şekilde
yerleştirilecektir.
13 / 126
EK-5
TAAHHÜTNAME
TÜRKSAT UYDU HABERLEŞME KABLO TV VE İŞLETME A.Ş.
ANKARA
1) “Türksat Kablo Sistemleri Malzeme Standartları ve Onaylı Ürün Talimatı” kapsamındaki tüm hükümlere
uyacağımı kabul ve taahhüt ediyorum/ediyoruz.
2) Türksat İOF (İş Ortağı Firmaları) firmalarına onaylı ürün sağlayıcı listesinde bulunmayan ürün sattığımın
tespiti halinde,


Ürün başına 50.000 TL cezayı 15(onbeş) gün içerisinde ödemeyi kabul ve taahhüt ediyorum
/ediyoruz.
Bu durumun 1 defadan fazla olması durumunda onaylı ürün sağlayıcı listesinden çıkarılmayı ve 5 yıl
boyunca onaylı ürün sağlayıcı listesine alınmayacağımı kabul ve taahhüt ediyorum/ediyoruz.
3) Türksat Kablo Sistemleri Malzeme Standartları ve Onaylı Ürün Talimatı kapsamında onay aldığım ürünlerin
sahadan alınan numunelerinde, Türksat tarafından yapılan/yaptırılan testlerin sonucunda uygunsuzlukla
karşılaşılması halinde ;



Ürün başına 10.000 TL cezayı 15(onbeş) gün içerisinde ödemeyi kabul ve taahhüt ediyorum
/ediyoruz.
Bu durumun 3 defadan fazla olması durumunda onaylı ürün sağlayıcı listesinden çıkarılmayı ve 5 yıl
boyunca onaylı ürün sağlayıcı listesine alınmayacağımı kabul ve taahhüt ediyorum/ediyoruz.
Süresinde ödenmeyen cezalar için MS listesinden çıkarılmayı kabul ve taahhüt ediyorum/ediyoruz.
_ _/_ _/_ _ _ _
Ad SOYAD/Unvan-(Kaşe)
İmza
14 / 126
KABLO SİSTEMLERİ
MALZEME TEKNİK
ÖZELLİKLERİ
15 / 126
AMAÇ:
Türksat A.Ş. kablo sistemlerinde kullanılacak olan malzemelerin teknik özelliklerinin neler olduğunun tariflenmesidir.
1.
KISALTMALAR:
TÜRKSAT
: Türksat Uydu Haberleşme Kablo TV ve İşletme A.Ş.
FİRMA
: Kablolu TV şebekesinde TÜRKSAT adına bakım-onarım-hasar, kurulum-iptal ve proje işlerini
gerçekleştiren yüklenici
2.
GENEL HUSUSLAR:
a)
Standartlarda yer almayan malzeme ve/veya malzemenin özellikleri için uluslar arası geçerli standartlar
(EN/CENELEC, ASTM/ANSI, IEC, ISO, TSE, BS, DIN) baz alınacaktır.
b) Yürürlükteki Kablo Sistemleri Malzeme Standartlarına uygun olmayan ürünler kesinlikle kullanılmayacak olup,
tespiti halinde cezai yaptırım uygulanacaktır. Cezai yaptırım detayları şartnamelerde belirlenmiştir.
c) Bununla birlikte “Kablo Sistemleri Onaylı Ürün Esasları” kapsamında onaylı ürün uygulaması yapılan
malzemeler için; Türksat’ın onaylı ürün listesinde yer almayan hiçbir malzeme yürürlükteki “Kablo Sistemleri
Malzeme Standartlarını” karşılasa bile şebekede kullanılmayacaktır. Onaylı ürünler, sadece Türksat’tan
yeterlilik almış onaylı ürün sağlayıcılardan tedarik edilecektir. Aksi hallerde cezai yaptırım uygulanacaktır.
Cezai yaptırım detayları şartnamelerde belirlenmiştir.
d) Her hangi bir marka modelde malzemenin Kablo Sistemleri Onaylı Ürün Esaslarını sağlamaması nedeniyle
TÜRKSAT tarafından onaylı ürün listesine alınmaması veya onaylı ürün listesinden çıkarılması durumunda
FİRMA nın bu duruma itiraz hakkı yoktur.
16 / 126
ALTYAPI MALZEMELERİ
TEKNİK ÖZELLİKLERİ
17 / 126
HDPE KIVRIMLI ÇİFT CİDARLI BORULAR
VE AKSESUARLARI
18 / 126
1)
a)
GENEL HÜKÜMLER
Çift cidarlı HDPE borular; manşonla birleştirmeli tipte olacaktır. HDPE boruların uzunlukları 6 m olacaktır.
b) Boru uçları, boru eksenine dik olarak kesilmiş olacak, boruda, kabarıklık ve boşluk bulunmayacak, borunun içi ve
dışı arasında suyun ve toprağın girmesine izin veren hiçbir delik, çatlak olmayacak ve doku homojen olacaktır.
c)
Boruların ve birleştirme manşonlarının iç ve dış yüzeyleri pürüzsüz olacak, borularda keskin kenar, çapak vb.
kusurlar olmayacaktır.
d) HDPE borular ve birleştirme manşonları için kullanılacak hammadde, orijinal rafineri şartlarında üretilmiş ve
daha sonra kırmızı renk (RAL 3020) karıştırılmış PE olacaktır. Hurda (Kullanılmış) PE hammaddeler kesinlikle
kullanılmayacaktır.
e)
Borunun güneş ışınlarına dayanıklılığını arttırmak için UV katkılı, ekstrüzyona hazır granül şeklinde olacaktır.
f)
HDPE borular düz bir zeminde bükümsüz veya kıvrımsız olarak tesis edilecektir. HDPE borunun tesisi sırasında
borulara hasar verilmeyecektir.
g)
Granül halindeki hammadde içine, imalatçı firma tarafından, boru ve ek parçalarının imali sırasında hiçbir
yabancı madde katılmayacak ve hammadde orijinal haliyle kullanılacaktır.
h) Boruların her iki ucunda da manşon içinde kalacak kısmı beyaz renkli çıkmaz boya ile şerit şeklinde
işaratlenecektir. Bu işaret bant sarılması şeklinde olmayacaktır.
i)
HDPE 50 ve 75 boru kroki resimleri ve ölçüleri aşağıda verilmiştir.
Cidarlı HDPE 75 Boru:
Cidarlı HDPE 50 Boru:
19 / 126
2)
MALZEME TESTLERİ
Hammadde Özellikleri
HDPE Malzemesinin Özellikleri
Malzeme Hammaddesi
Renk
Yoğunluk
Erime Akış Hızı ( 2160 g, 190ºC )
Kopma Mukavemeti
Bükülme Modülü
Kopma Uzaması
İstenen Değer
HDPE 50
HDPE 75
RAL 3020 (Kırmızı)
RAL 3020 (Kırmızı)
Min. 0,940 g/cm³
Min. 0,940 g/cm³
< 0,15 g/10 dak.
< 0,15 g/10 dak.
Min. 19MN/m²
Min. 25MN/m²
Min. 1.200 MN/m²
Min. 1.200 MN/m²
> 500 %
> 500 %
> 48 saat (2/10
> 48 saat (2/10 hata)
hata)
E.S.C.R ( %10 Igepal C-630 )
Test Yöntemi
BS 3412:ISO 1872
BS 3412:ISO 1133 Pro.4
BS 3412:ISO/R527 Type2 Sp.D
BS 2782:1978:335A
BS 3412:ISO/R527 Type2 Sp.D
ASTM 1693
Cidarlı HDPE Boru Bitmiş Ürün Testleri
Yapılacak Testler
İstenilen Özellik
31,5 kN/m² ye göre,
max deformasyon =
0,03 x Boru iç çap
Deformasyon Mukavemeti
Darbe Testi
Max 3/12 Çatlama
Min. 19MN/m² (HDPE 50)
Min. 25MN/m² (HDPE 75)
Kopma Mukavemeti
Kopma Uzaması
> 375 %
Yoğunluk
Pigment Miktarı
Pigment Dağılımı
E.S.C.R ( %10 Igepal C-630 )
3)
Üretici Firmanın Adı
İç Çap
İmalat Tarihi
(AA-YYYY)
“TÜRKSAT KABLO”
a)
DIN 16961 Part 1-2
BS EN 50086-2-4
Tablo 102
BS 3412:ISO/R527
Type2 Sp.D
BS 3412:ISO/R527
Type2 Sp.D
BS 3412:ISO 1872
ASTM 1603
BS 2782, 823 A
ASTM 1693
Alınacak Numune
HDPE Boru
HDPE Boru
HDPE’den mamül ürün
HDPE’den mamül ürün
HDPE’den mamül ürün
HDPE’den mamül ürün
HDPE’den mamül ürün
HDPE’den mamül ürün
İŞARETLEME
İŞARETLER
4)
Min. 0,940 g/cm³
%2,5 ± 0,5
Max 5 nolu resim
> 48 saat (2/10 hata)
Test Metodu
AÇIKLAMALAR
Boruların üzerine her iki uçtan 1 metre mesafeye ve
diğer tüm aksesuarlara yazılır.
Boruların üzerine her iki uçtan 1 metre mesafeye ve
diğer tüm aksesuarlara yazılır.
Boruların üzerine her iki uçtan 1 metre mesafeye ve
diğer tüm aksesuarlara yazılır.
Boruların üzerine her iki uçtan 1 metre mesafeye yazılır.
BİRLEŞTİRME MANŞONU
HDPE 50 ve 75 birleştirme manşonun malzemesi ve rengi, boru ile aynı olacaktır.
b) Manşonun tam ortasında boru et kalınlığını geçmeyecek ve borunun karşı uçtan çıkmasını engelleyecek şekilde
en az dört noktada durdurma takozu olacaktır. Ayrıca manşonun her iki ucunda da en az ikişer adet borunun
kolayca çıkmasını engelleyecek esnek tırnak yer alacaktır.
c)
Manşon boyu HDPE 75 için minimum 135 mm, HDPE 50 için ise minimum 115 mm olacaktır.
20 / 126
İKİ GÖZLÜ HDPE 40 BORU & HDPE 63 BORU & 3’LÜ
GÖZ ÇOKLAYICI
VE AKSESUARLARI
21 / 126
GENEL HÜKÜMLER
a)
Boru uçları, boru eksenine dik olarak kesilmiş olacak, boruda, kabarıklık ve boşluk bulunmayacak, borunun içi ve
dışı arasında suyun ve toprağın girmesine izin veren hiçbir delik, çatlak olmayacak ve doku homojen olacaktır.
b) HDPE Boru hammaddesine rafine şartlarında UV tutucu (ultraviyole ışınlarına karşı dayanıklı) katılmış, ısıya karşı
dayanıklı ve kırmızı renkte (RAL 3020) olacaktır. Hurda PE hammadde kesinlikle kullanılmayacaktır.
c)
Granül halindeki hammadde içine, imalatçı firma tarafından, boru ve ek parçalarının imali sırasında hiçbir
yabancı madde katılmayacak ve hammadde orijinal haliyle kullanılacaktır.
d) HDPE 50 ve 75 boru kroki resimleri ve ölçüleri aşağıda verilmiştir.
e)
HDPE borunun alt ucu 000’dan başlayıp her metrede bir metraj rakamı basılacaktır.
f)
HDPE boruların üzerine her metrede 1 adet, 4mm. genişliğinde HDPE boru tanım yazısı yazılacaktır. Tanım
işaretleri çıplak gözle okunabilecektir.
g)
Tanıtım işaretleri HDPE boru üzerine çıkmayacak şekilde yazılacak olup, bu yazı ve işaretler kimyasal maddelere
ve atmosfer koşullarına dayanıklı olacak, kolayca kazınıp çıkmayacaktır.
h) Her bir kangal HDPE boru numarası 9 karakterden oluşan bir seri numarası ile tanımlanacaktır. Bu yönteme göre
aşağıdaki örnekte olduğu gibi numaralar birbirini izleyecek şekilde verilecektir.
Örnek: 2013 yılı yedinci ayında üretilen HDPE boru için;
07
13
00001
HDPE seri numarası
Üretim yılının son iki basamağı
Üretim ayı iki basamak
i)
İki gözlü HDPE 40 boru & 3’lü göz çoklayıcı kroki resmi ve ölçüleri aşağıda verilmektedir.
22 / 126
Hammadde Özellikleri
HDPE Malzemesinin Özellikleri
Malzeme Hammaddesi
Renk
Yoğunluk
Erime Akış Hızı ( 2160 g, 190ºC )
Kopma Mukavemeti
Kopma Uzaması
E.S.C.R ( %10 Igepal C-630 )
İstenen Değer
HDPE 40
RAL 3020 (Kırmızı)
Min. 0,940 g/cm³
< 0,15 g/10 dak.
Min. 24MN/m²
> 650 %
> 48 saat (2/10 hata)
Test Yöntemi
BS 3412:ISO 1872
BS 3412:ISO 1133 Pro.4
BS 3412:ISO/R527 Type2 Sp.D
BS 3412:ISO/R527 Type2 Sp.D
ASTM 1693
HDPE Boru Bitmiş Ürün Testleri
Yapılacak Testler
Darbe Testi
Kopma Mukavemeti
Kopma Uzaması
Yoğunluk
Pigment Miktarı
Pigment Dağılımı
E.S.C.R ( %10 Igepal C-630 )
Bükülme Testi
İstenilen Özellik
Test Metodu
Alınacak Numune
BS EN 50086-2-4
Max 3/12 Çatlama
HDPE Boru
Tablo 102
BS 3412:ISO/R527
Min. 24MN/m²
HDPE’den mamül ürün
Type2 Sp.D
BS 3412:ISO/R527
> 600 %
HDPE’den mamül ürün
Type2 Sp.D
Min. 0,940 g/cm³
BS 3412:ISO 1872 HDPE’den mamül ürün
%2,5 ± 0,5
ASTM 1603
HDPE’den mamül ürün
Max 5 nolu resim
BS 2782, 823 A
HDPE’den mamül ürün
> 48 saat (2/10 hata)
ASTM 1693
HDPE’den mamül ürün
Dış çapın 4 katına eşit bir yarıçapla bükülmesi durumunda bükülen yerde her
hangi bir bozulma, çatlama, kırılma vb. olmayacaktır.
PE63 Hammadde Özellikleri
HDPE Malzemesinin Özellikleri
Malzeme Hammaddesi
Renk
Yoğunluk
Erime Akış Hızı ( 2160 g, 190ºC )
Kopma Mukavemeti
Kopma Uzaması
Bükülme Modülü
E.S.C.R ( %10 Igepal C-630 )
5)
İstenen Değer
HDPE 40
RAL 3020 (Kırmızı)
Min. 0,940 g/cm³
< 0,15 g/10 dak.
Min. 24MN/m²
> 500 %
Min. 1,2 MN/m²
> 48 saat (2/10 hata)
Test Yöntemi
BS 3412:ISO 1872
BS 3412:ISO 1133 Pro.4
BS 3412:ISO/R527 Type2 Sp.D
BS 3412:ISO/R527 Type2 Sp.D
BS 2782:1978:335A
ASTM 1693
TIKAMA KEPİ
Ek odalarında, kablo çekilmeyen HDPE 40 boru içerisine su ve pisliğin girmesini önlemek amacıyla HDPE 40 boru
ağızları, aşağıdaki kepler kullanılarak kapatılacaktır. Tıkama keplerinin malzemesi, HDPE borularının malzemesi ile
aynı olacaktır.
23 / 126
6)
EK MANŞONLARI
HDPE boruların birbirine eklenmesi amacıyla ek manşonları kullanılacaktır. Kullanılacak bu özel amaçlı ek manşonları
simetrik, iki ucu ayrı ayrı vidalanacak, montaj sırasında fazla kuvvet uygulamalarında vida dişleri bozulmayacaktır.
Ek Manşonlarının her iki ucu istendiğinde kolayca açılabilecek, sızdırmazlığı sağlamak amacıyla Ek Manşonunun iç
kısımı ile HDPE Boru arasında sökülüp takılabilir conta olacaktır.
Ek Manşonlarında delik, çizik, çapak ve onarılmış kısımlar bulunmayacaktır. Görünümü düzgün ve homojen olacaktır.
7)
ÖZEL DURUMLARDA KULLANILACAK BORULAR
Yatay sondaj gibi özel durumlarda aşağıda şekilleri verilen 16 ATU borular kullanılacaktır. Söz konusu borular en az
yukarıda verilen özellikleri sağlayacaktır.
BORU
EN BÜYÜK
DIŞ ÇAP
OVALLİKTEN En Büyük
SAPMA
EN DÜŞÜK
ET KALINLIĞI
EN YÜKSEK
ET KALINLIĞI
Ø 75 x 6.8 mm SDR 11 PN 16 BORU
75.4 mm
1.6 mm
6.8 mm
7.6 mm
24 / 126
YUVARLAK BETON EK ODALARI
VE KAPAKLARI
25 / 126
1)
a)
TİP 200 EK ODASI
Küp dayanımı 50 MPa dayanımında ve TSE standartlarına uygun beton kalitesinde buhar kürlü olarak imal
edilecektir. Tabanda, 20 cm çapında delik bulunacaktır. Gövdede 8 adet (her yüzde 2 adet) 8 cm çapında delik
bulunacak, deliğin duvarının iç cephesine 2 cm kalınlık kısmı betonla dolu, iç kısmı boş olacaktır. Deliğin en alt
noktasının taban plakasından yüksekliği en az 10 cm en fazla 20 cm olacaktır. İhtiyaç duyulan deliğin betonu
çekiç darbesiyle kırılabilecek özellikte olacaktır. Diğer özellikler aşağıdaki teknik çizime göre imal edilecektir.
b) Ek Odası 3 parçalı ve çerçevesi demonte edilebilir yapıda olacaktır. Sızdırmazlık için ara parçalarda lastik conta
kullanılacaktır. Donatı olarak Q 188/188 tipinde hasır çelik veya 0.90x60 Mix ÇELİK TEL kullanılacaktır. Çelik hasır
göz aralığı 15cm olacaktır.
c)
CTP kapağın çerçevesi metalden veya SFERO DÖKÜM den yapılmış ve imalat sırasında betona sökülemeyecek
şekilde altı noktadan civata ile monte edilmiş olacaktır.
d) Elemanların boyutları şartnamede ki çizimlere ve TS-821, EN-1916/Mart 2005 ve TS EN 1917/10.03.2005 deki
fiziksel ve mekanik özelliklere uygun olacaktır. Prefabrik elemanların hatalı olması, kalıptan dolayı oluşabilecek
deformasyon, kalıptan taşma, mamul malzemenin kalınlığının (toleranslar dahilinde olmalı) her yerde aynı
olmaması ve yüzey pürüzlülüğü, kırık ve çatlaklar (gözle görülen kılcal çatlaklar dahil) gibi durumlardaki
malzemeler kesinlikle teslim alınmayacaktır. Tüm malzemeler TSE ve ilgili standartlara uygun olacaktır. Beton ve
betonarme elamanlarına istisnasız tümüne doymamış buhar kürü uygulayacaktır. civata ile)
e)
Dış ölçüleri Ø88 cm & H=90 cm, üç parçalı, alt/orta parçada 8 delikli olarak (TİP 100A/200A) veya dış ölçüleri Ø88
cm & H=105 cm, üç parçalı, alt parçada 8 delik ve orta parçada 8 delikli olarak (TİP 100B/200B) yapılacaktır.
(Teknik resimlerde belirtildiği gibi olacak. Deliklerin yerleri temsili olarak çizilmiştir.) Ek odası parçalarının diş
derinlikleri minimum 5 cm olacaktır.
f)
Ek odasi üst parçasina çinko/galvaniz kaplamalı metalden yapılmış ankrajlı levha (civata bağlantısı için üzerinde
6 adet karşilik-somun olan) koyularak ek odasi üst parça imal edilecek ve 4 adet 16mm civata ile CTP kapak
çerçevesi üstten montaj edilecektir.
g)
Asfalt vb kaplamalı yollarda üst kotta değişiklik ihtiyacı oluştuğunda bağlantı elamanları gevşetilerek/uzun boy
civata kullanılarak metal çerçeve altı beton veya grout harçları ile doldurularak menhol kotu 7 cm e kadar
ayarlanabilecektir. 7 cm in üzerindeki yükseltmeler veya alçaltmalarda menhol üst parçasi değiştirilerek
yükseklik ayarlanabilecektir.
TİPİ
Q 188/188
ÇAP
6mm
ÇELİK HASIR
AKMA MUKAVEMETİ ÇEKME MUKAVAMETİ
Min. 5000 kg/cm2
Min. 5500 kg/cm2
UZAMA
%8
Göz Aralığı
15/15
ÇELİK LİF
TİPİ
BETON İÇİNDEKİ MİKTAR
STANDART
0.90x60 MİX ÇELİK TEL
25kg/m³-30kg/m³
TS–10514-Aralık 1992
26 / 126
 Metal / Sfero Çerçeveli Kompozit Kapaklı Ek odası:
 Ek odası alt parçanın üstten ve yandan görünüşü:
27 / 126
28 / 126

Metal Alt parça (Betonarme elemana Ankraj Parçası)
29 / 126

Ek odası yükseltme parçasının üstten ve yandan görünüşü
30 / 126

TİP 200A Metal/Sfero Çerçeveli Ek odası üç boyutlu görünüşü

TİP 200B Metal/Sfero Çerçeveli Ek odası üç boyutlu görünüşü
31 / 126
2)
a)
TİP 100 EK ODASI
Küp dayanımı 50 MPa dayanımında ve TSE standartlarına uygun beton kalitesinde buhar kürlü olarak imal
edilecektir. Tabanda, 20 cm çapında delik bulunacaktır. Gövdede 8 adet (her yüzde 2 adet) 12 cm çapında yarım
delik bulunacak, deliğin duvarının iç cephesine 2 cm kalınlık kısmı betonla dolu, iç kısmı boş olacaktır. Deliğin
taban plakasından yüksekliği 10 cm olacaktır. İhtiyaç duyulan deliğin yarım betonu çekiç darbesiyle kırılabilecek
özellikte olacaktır. Diğer özellikler aşağıdaki teknik çizime göre imal edilecektir.
b) Ek Odası 3 parçalı ve çerçevesi demonte edilebilir yapıda olacaktır. Sızdırmazlık için ara parçalarda lastik conta
kullanılacaktır. Donatı olarak Q 188/188 tipinde hasır çelik kullanılacaktır. Çelik hasır göz aralığı 15cm olacaktır.
c)
CTP kapağın çerçevesi CTP den yapılmış ve imalat sırasında betona gömülü olarak üretilmiş olacaktır.
d) Elemanların boyutları şartnamede ki çizimlere ve TS-821, EN-1916/Mart 2005 ve TS EN 1917/10.03.2005 deki
fiziksel ve mekanik özelliklere uygun olacaktır. Prefabrik elemanların hatalı olması, kalıptan dolayı oluşabilecek
deformasyon, kalıptan taşma, mamul malzemenin kalınlığının (toleranslar dahilinde olmalı) her yerde aynı
olmaması ve yüzey pürüzlülüğü, kırık ve çatlaklar (gözle görülen kılcal çatlaklar dahil) gibi durumlardaki
malzemeler kesinlikle teslim alınmayacaktır. Tüm malzemeler TSE ve ilgili standartlara uygun olacaktır. Beton ve
betonarme elamanlarına istisnasız tümüne doymamış buhar kürü uygulayacaktır. civata ile)
e) Dış ölçüleri Ø88 cm & H=90 cm, üç parçalı, alt parça ile orta parça birleşim yerinde 8 delikli olarak (TİP 100A)
veya dış ölçüleri Ø88 cm & H=105 cm, üç parçalı, alt parçada 8 delik ve orta parçada 8 delikli olarak (TİP
100B); şekillerdeki teknik resimlerde belirtildiği gibi yapılacaktır. Ek odası parçalarının diş derinlikleri
minimum 5 cm olacaktır.

TİP 100A CTP Çerçeveli Kompozit Kapaklı Ek Odası
32 / 126

TİP 100B CTP Çerçeveli Kompozit Kapaklı Ek odası
33 / 126

TİP 100A CTP Çerçeveli Ek odası üç boyutlu görünüşü

TİP 100B CTP Çerçeveli Ek odası üç boyutlu görünüşü
34 / 126
3) Tip 300A EK ODASI:
a) Küp dayanımı 50 MPa dayanımında ve TSE standartlarına uygun beton kalitesinde buhar kürlü
olarak imal edilecektir. Tabanda, 20 cm çapında delik bulunacaktır. Gövdede 4 adet (her yüzde 1
adet) 20 cm çapında yarım delik bulunacak, deliğin duvarının iç cephesine 2 cm kalınlık kısmı
betonla dolu, iç kısmı boş olacaktır. İhtiyaç duyulan deliğin yarım betonu çekiç darbesiyle
kırılabilecek özellikte olacaktır. Diğer özellikler aşağıdaki teknik çizime göre imal edilecektir.
b) Ek Odası 2 parçalı ve çerçevesi demonte edilebilir yapıda olacaktır. Sızdırmazlık için ara parçalarda
lastik conta kullanılacaktır. Donatı olarak Q 188/188 tipinde hasır çelik kullanılacaktır. Çelik hasır
göz aralığı 15cm olacaktır.
c) CTP kapağın çerçevesi CTP den yapılmış ve imalat sırasında betona gömülü olarak üretilmiş
olacaktır.
d) Elemanların boyutları çizimlere ve TS-821, EN-1916/Mart 2005 ve TS EN 1917/10.03.2005 deki
fiziksel ve mekanik özelliklere uygun olacaktır. Prefabrik elemanların hatalı olması, kalıptan dolayı
oluşabilecek deformasyon, kalıptan taşma, mamul malzemenin kalınlığının (toleranslar dahilinde
olmalı) her yerde aynı olmaması ve yüzey pürüzlülüğü, kırık ve çatlaklar (gözle görülen kılcal
çatlaklar dahil) gibi durumlardaki malzemeler kesinlikle teslim alınmayacaktır. Tüm malzemeler
TSE ve ilgili standartlara uygun olacaktır. Beton ve betonarme elamanlarına istisnasız tümüne
doymamış buhar kürü uygulayacaktır. civata ile)
e) Dış ölçüleri Ø88 cm & H=90 cm, iki parçalı, alt parça 4 delikli (her yüzde 1 adet 20 cm. çapında)
olarak şekillerdeki teknik resimlerde belirtildiği gibi yapılacaktır. Ek odası parçalarının diş
derinlikleri minimum 5 cm olacaktır..
35 / 126
4) KOMPOZİT EK ODASI KAPAĞI (CTP)
a)
Ek odasının üst parçasının üzerine 40 ton (D 400 ) dayanımı sağlayacak standartlara uygun kesit ve kalınlıkta tam
geri dönüşümsüz CTP rögar kapağı monte edilecektir. TS 1478 EN 124 Standarttında belirtilen teknik verilere
uygun olacaktır.
b) Kapak et kalınlığı üzerinden geçen yoğun trafiğe dayanıklı olacak şekilde üretilmiş olacaktır. Kapak menhole ve
yüzeye sıfır olacak şekilde gömük olarak yerleştirilecektir.
c)
Kapak üzerindeki geçme parçası ve kalın diş cıvata yardımı ile gövdeye bağlanacaktır.
d) Kapak ve çerçeve, özellikleri TS–1478, EN–124 standardına göre CTP hamuru kullanılarak üretilecektir.
e)
Betonarme ek odası kapama elemanı çerçeveye menteşe ile değil, üç noktadan bağlantı yapacak şekilde
tasarlanmış bir kilit mekanizması ile monte edilmelidir. Betonarme ek odası kapama elemanında kilit sisteminin
tam karşısında çerçevede bulunan yuvaya girerek sabitlemeyi sağlayacak bir sabitleme çıkıntısı bulunmalıdır.
Kapak bu şekilde karşılıklı bir çok noktadan sabitlenerek emniyet altına alınmalı ve ses yapması engellenmelidir.
Betonarme ek odası kapama elemanının çerçeve oturma yüzeyi ile uyumlu olabilmesi, kullanımda stabiliteyi ve
sessizliği sağlayabilmesi için kapak altı yatak malzemesi olarak Rögar Contası kullanılacaktır.
36 / 126
f)
Çerçeve ve kapak temas yüzeylerinin geometrik düzgünlüğü TS–2040, ISO–1302 standardına uygun olmalıdır.
Kompozit çerçeve ve kapakların yüzeyleri düzgün olacak; kabarcık, katmerlenme ve çatlak bulunmamalıdır.
Kompozit (CTP) çerçeve ve kapak malzemesinin rengi yüzey boyaması ile değil kompozit hamurunun tümü
renklendirilerek yapılmalıdır.
g)
Kompozit (CTP) Malzemeden imal edilecek ürünlerin kilitleme sistemlerinde kullanılacak somun ve civatalar 10.9
sertlik kalitesinde trifon dişli ve dacromet (RIV/DAC) kaplama olup, kaplama cinsi Grade – A (RIV/DAC5) ve
kaplama kalınlığı 5 mikron (25 g/m2) olmalıdır. Kilit vidasının ürüne montajından sonra yerinden kolayca
çıkmaması için rondela ve segman takılacaktır.
h) Kullanılacak civatalara ilişkin teknik çizimler aşağıdaki gibidir.
i)
Kompozit ürünlerde kullanılacak kilitleme/açma anahtarı, kilitleme ve açma işlemleri sırasında özelliklerini
kaybetmeyecek (alyan kısmı aşınmayacak, kırılmayacak, bükülmeyecek vb.) yapıda kol kısmı 1050 kalitesinde,
alyan uç kısmı DIN 912 12.9 kalitesinde çelikten imal edilecektir. Kilitleme/Açma anahtarı korozyona uğramaması
için galvaniz kaplama olacaktır.
j)
Kapağın altına 30x30 2mm kalınlığında galvanizli saç levha eklenecektir. Levha kimyasal yapıştırıcı ile yapıştırılıp
dört köşeden vida ile tutturulacaktır.
Muayeneler:

Gözle Muayene
Gelişi güzel alınan numunelerin tamamı gözle muayene edilmelidir. Yine aynı numuneler üzerinde uygun görülen
miktarda oturma yüzeyi düzgünlüğü kontrolu yapılmalıdır.
37 / 126

Boyut Muayenesi
Gelişi güzel alınan numunelerin verilen boyut ve toleranslara uygun olup olmadığı kontrol edilmelidir. Ölçülen her
boyut için kapama elemanının 3 (üç) ayrı yerinde yapılan ölçmelerin ortalaması alınarak değerlendirme yapılmalıdır.

Kompozisyon
Kompozit (CTP) kapama elemanı çerçeve ve kapak malzemesi kompozisyonunun değerleri sağlayıp sağlamadığı ilgili
standartlar uyarınca kontrol edilmelidir.
k)
İşaretleme:
Bakım Rögarı Kapama elemanında baskı işlemi sırasında kabartmalı olarak yazılmış aşağıdaki bilgiler olacaktır;
— Türksat’a ait logo ve yazılar kapağın göbeğinde olacaktır,
— İlgili standardın işareti,
— Standartta adı geçen uygun sınıf,
— TSE işareti.

Ek odası kapağı üç boyutlu görünüşü
38 / 126
KOMPOZİT KARE EK ODASI
39 / 126
a)
Malzeme, gövde ve kapak olmak üzere iki ana kısımdan oluşak ve 12,5 Ton yüke dayanıklı olacaktır.
b) Kapak ve Gövde, Cam Elyaf Takviyeli Doymamış Polyester olup aşağıdaki tabloda verilmiş olan TS 1478 EN 124
standardına göre CTP Hamuru kullanılarak üretilmelidir.
c)
Kompozit Ek Odası kapağı gövdeye trifon dişli cıvata ve somun ile sabitlenmelidir.
d) Kilit mekanizmasında 10.9 Kalitesinde 12x25 Trifon Cıvata, ve Somun kullanılmalıdır.
e)
Ek Odası, gövde oturma yüzeyi ile uyumlu olabilmesi, kullanımda stabiliteyi ve sessizliği sağlayabilmesi için kapak
altı yatak malzemesi olarak aşağıda teknik özellikleri verilen conta kullanılmalıdır.
40 / 126
f)
EK Odası aşağıda verilen ölçülerle imal edilmelidir. Ölçüler mm. cinsinden olup toleranslar ± 2 mm’dir.
Kapak Genişlik (mm)
:452
Kapak Boy (mm)
:452
Kapak Kalınlık (mm)
:20
Gövde Genişlik (mm)
:483
Gövde Boy (mm)
:483
Gövde İç Derinlik (mm)
:390
Kilit Sayısı (Adet)
:1
Kapak Sabitleme çıkıntısı (Adet)
:2
Kütlesi (Minimum Kg)
:18,0
g)
Gövde ve kapak temas yüzeylerinin geometrik düzgünlüğü TS 2040 ISO 1302 standardına uygun olmalıdır.
h) Kompozit gövde ve kapakların yüzeyleri düzgün olacak; kabarcık, katmerlenme ve çatlak bulunmamalıdır.
i)
Gövde ve kapak malzemesinin rengi yüzey boyaması ile değil kompozit hamurunun tümü renklendirilerek
yapılmalıdır.
41 / 126
j)
Üretici Firma, EN ISO 9001 Sertifikasına, ISO 14001 Sertifikasına, OHSAS 18001 Sertifikasına ve Kapasite
Belgesine sahip olmalıdır.
k)
Ek Odası kapağında üzerinde pres işlemi sırasında kabartmalı olarak yazılmış TÜRKSAT logosu olmalıdır.

Ek odası görünüşü
42 / 126
FİBER OPTİK KABLO VE
AKSESUARLARI
TEKNİK ÖZELLİKLER
43 / 126
FİBER OPTİK KABLOLAR
44 / 126
1) TEKNİK ÖZELLİKLER
1.1 Kablo Tipi
a) Kablolar, yeraltında/havai döşemeye uygun (yeraltı-tipi- Şekil-1, Şekil-2, Şekil-3, Şekil-4, Şekil-5, Şekil-7), 4 / 12 /
24 / 96 / 144 / 216 fiberli tek kılıflı olacaktır. 4FO kablo çift kılıflı olacaktır.
b)
Kablolar, IEC–60793, IEC–60794 standartlarına uygun olarak üretilecek ve test edilecektir.
c)
Fiber damar teknik özellikleri, ITU-T G.652.D standartlarına uygun olacaktır.
d)
Fiberler, bir merkez elemanı etrafına sıralanmış, gevşek tüpler içerisine yerleştirilmiş olacaktır. Merkez elemanı
etrafındaki tüp sayısı 6 / 8 / 12 / 18 (6+12 şeklinde iki katman) adet olacaktır. 4 fiberli kabloda merkez eleman
olmayacak merkezden PBT tüp geçirilecektir.
1.2 Fiber Elyafın Özellikleri
a)
Optik İletimi sağlayacak fiber, tek modlu (single mode) olacaktır.
b)
FİRMA, optik fiberin hangi yöntemle üretildiğini, hangi firmadan alındığını, zayıflama değerlerinin ne olduğunu
gösteren, üretici firmadan alınan onaylı belgeyi teklifte verecektir.
c)
Fiberin 1310 nm ,1550 nm ve 1625 nm'deki kırılma indisIeri ayrı ayrı belirtilecektir.
d)
Standart fiber optik kablodaki fiber optik elyaflar, EK-1’de yer alan Tablo-1’de belirtilen özelliklere uygun
olacaktır.
e)
Fiber üzerindeki koruyucu kılıf (coating) zamanla bozulmayacak ve mekanik sıyırıcılarla kolayca sıyrılacaktır.
f)
Fiberi oluşturan cam tabaka (core + cladding) UV ışığı ile kuruyabilen, üretan akrilik tipi malzeme ile iki kat
kaplanmış olacaktır.
g)
Fiberler, fiber tüplerin içerisine helisel olarak yerleştirilecek ve herhangi bir yöntemle birleştirilmeyecektir,
kablo boyunca tek parça olacaktır.
h)
Fiber renkleri EK-1’de yer alan Tablo-2’de verildiği şekilde olacaktır. Belirtilen renklendirme (ASTM D 1535
standartlarına uygun ) UV tekniği ile yapılacak ve fiber renkleri kullanılan fiber tüp dolgu maddesi ile
bozulmayacaktır. 4 Fiberli kabloda sıralamadaki ilk dört renk kullanılacaktır.
i)
Fiber elyaflar aşağıda istenilen ölçüm ve deney yöntemlerini sağlayacaktır. TÜRKSAT, istenilen fiber örnekleri
üzerinde aşağıda belirtilen testleri uygulayabilecek ve değerleri sağlayıp sağlamadığını kontrol edebilecektir.
Özellikleri
Fiberin bükülme yarıçapı (tek)
Fiberin bükülme yarıçapı (yeniden)
Fiberin mekanik dayanaklılığı
j)
Birimi
mm
mm
N/mm²
Sağladığı Değer
≤30
≤30
≥730
Test Yöntemi
IEC-793-1 B2A
IEC-793-1 B2A
IEC-793-1 B2A
TÜRKSAT, istediği zaman, Fiber optiğin parametre testlerinde; EK-1’de yer alan Tablo-1'de belirtilen özelliklere
uygun olup olmadığını üretim sırasında kontrol edebilecektir.
1.3 Fiber Tüp
a)
Dış etkilerden korumak amacıyla fiberler, dairesel, esneklik katsayısı yüksek bir tüp içerisine yerleştirilecektir.
b)
Bu tüpler gevşek (loose) tipte olacak ve et kalınlığı teklifte belirtilecektir.
c)
Fiber tüplerin yapısı tek katmanlı PBT’den oluşacaktır. PBT zamanla büzüşmeyecek (Low Shrink) özellikte
olacaktır.
45 / 126
d)
Fiber tüp için kullanılacak PBT aşağıdaki özellikleri sağlayacaktır.
Özellikleri
Yoğunluk (PBT)
İçerdiği Su (23°C)
Kopma kuvveti
Kopma uzaması
Esneklik katsayısı
Sertlik
Erime sıcaklığı (DSC)
Sıcaklık Gen. Kat.
(-23 ≤ ≤+80°C)
Birimi
3
(g/cm )
%
(N/mm²)
(%)
(N/mm²)
Shore D
(°C)
-1
Sağladığı Değer
1,31+ 0,03
≤ 0.45
≥ 30
≥ 50
> 2200
> 78
> 220
-4
(°K x 10 )
Test Yöntemi
ISO 1183
DIN 53 495
ISO 527
ISO 527
ISO 527
DIN 53 505
ISO 3146 C
≤ 1,3
e)
Tüp, fiberlerin rahat hareket etmesini sağlayacak çapta ve iç yüzeyi pürüzsüz olacaktır.
f)
Fiber tüp, minimum genleşme ve büzüşme özelliğinde olacak, içine konacak dolgu maddesi ile kimyasal temizlik
maddelerinden etkilenmeyecek, kablo dolgu maddesini emmeyecektir.
g)
Tüpler, ek kutusu içerisinde ekleme gibi işlemler sırasında oluşabilecek bükülmelerden ötürü kırılmayacaktır.
h)
Fiber tüpler, belirli bir adım ile merkez elemanı çevresine SZ olarak sarılacaktır. Tek yönlü büküm kabul
edilmeyecektir.
i)
Fiber tüpler aşağıda istenilen ölçüm ve deney yöntemlerini sağlayacaktır.
Özellikleri
Fiber tüplerin bükülme çapı
Fiber tüplerin (Sarım) adım aralığı
Tüplerin Kıvrımları(Kinking)
Birimi
mm
mm
mm
Sağladığı Değer
≥ 20 x D
80-120
≥100
Test Yöntemi
IEC-794-1-E11
IEC-794-1
EN 187000 M 512
j)
Kablo kapasitelerine göre, tüpler RAL renk kodlarına göre EK-1’de yer alan Tablo-2‘deki renk sıralamasına uygun
olacaktır. 4 Fiberli kabloda sıralamadaki ilk renk (KIRMIZI RAL 3000) kullanılacaktır.
k)
Tüp renkleri zamanla bozulmayacak, kullanılacak renklendirici, PBT esaslı Masterbach olacaktır.
l)
Fiber sayısı, 216’lık kablo tipinde gevşek tüpler ikinci bir katman olarak ilk katmandaki gevşek tüplerin üzerine
eğrilecektir.
1.4 Fiber Tüp Dolgu Maddesi
a)
Su ve nemin tüp içerisine girmesini önlemek ve Fiberler üzerinde oluşacak ani hareketlerin etkisini en aza
indirmek üzere Fiber Tüpler dolgu maddesi ile doldurulacaktır. Dolgu maddesi aşağıdaki özelliklerde olacaktır.
Özellikleri
Yoğunluk (25°C)
Damlama Noktası (Drop Point)(24 Saat)
Drip Noktası(Drip Point)
Alevlenme noktası
Yağ Ayrışması (150°C, 24 saat)
Uçuculuk (150°C, 24 saat)
İçerdiği Su
Asit Değeri (100°C)
Aşınma
Birimi
3
(g/cm )
(°C)
(°C)
(°C)
(%)
(%)
(%)
(%)
(mg KOH/g)
Sağladığı Değer
0.85±0.05
Drip noktası’na uygun
≥70
≥230
0
≤2
<0.05
Test Yöntemi
DIN 51 757
IEC 811.5.1 B
REA PE 39
ISO 2592
FTM std 791 C
FTM std 791 C
DIN 5177
≤0.01
DIN 53 402
Pozitif
IEC 811.5.1
46 / 126
Koni batması (25°C)
Koni batması (-30°C)
Oksijen Induction zamanı (180°C)
Özdirenç (100-500 V)(100°C)
Özdirenç (100-500 V)(23°C)
(1/10)(mm)
(1/10)(mm)
(dak)
(Ω x m)
(Ω x m)
350-450
>150
>20
8
≥10
11
≥10
ISO 2137
ISO 2137
IEC 811.4.2.B
ASTM D 1169
ASTM D 1169
b)
Fiber tüp dolgu maddesi homojen olacak, içinde hava kabarcıkları veya başka bir yabancı madde parçacıkları
bulunmayacaktır.
c)
Tüp dolgu maddesinin, üreticisinden alınan ve standartlara uygun olduğunu belirten, test raporları TURKSAT’a
verilecektir.
d)
Yaşlanma etkisi için; 10 günlük bir zaman içerisinde 70°C sıcaklıkta yağ ayrışması ve uçuculuk değerleri
değişmeyecektir.
e)
Tüp dolgu maddesi yarı saydam renkte olacaktır. Kullanılacak Tüp dolgu maddesi optik fiberlerin renklerini
hiçbir şekilde değiştirmeyecek, bilinen ve kabul edilmiş birçok temizleyiciden herhangi biri (solvent) ile
temizlenecektir.
f)
İnsan sağlığını ve çevreyi olumsuz etkilemeyecek, rahatsız edici kokusu bulunmayacaktır.
g)
Dolgu maddesi ile doldurulmuş tüplerin, tam olarak doldurulup doldurulmadığının belirlenmesi için su
sızdırmazlık testi yapılabilecektir.
1.5 Fiber Optik Kablonun Öz Yapısı
a) Merkez Elemanı
Merkez eleman, kablonun merkezinde yüksek dayanımı olan sentetik elyaftan üretilmiş plastik destekli ve fiber kablo
içinde tek parça olacaktır. Merkezi eleman hiç bir yöntemle (kaynak vb.) eklenmeyecektir.
Kabloda kullanılacak merkez eleman, dairesel kesitli olacak, UV ile pişirilmiş yüzeyinde herhangi bir kusur (çizik,
çatlak, çapak, çentik, yağ, pas gibi yabancı maddeler) bulunmayacaktır.
Konfigürasyonu sağlamak amacıyla merkez elamanın üzeri polietilen bileşimi ile kaplanabilecektir. Polietilen et
kalınlığı teklifte belirtilecektir.
Fiber optik kablolarda kullanılacak fiber glass merkez elemanı aşağıda belirtilen standart ve özellikleri taşıyacaktır.
Özellikleri
Çap
Kopma kuvveti
Kopma uzaması
Esneklik katsayısı
Bükülme kuvveti
Bükülme çapı
Basınç kuvveti
İçerdiği su
Yoğunluk
Sıcaklık kararlılığı
Sıcaklık Gen. Kat.
Ovallik
Birimi
mm
(N/mm²)
(N/mm²)
(N/mm²)
mm
(N/mm²)
3
g/cm
(°C)
-1
-6
(°K x 10 )
mm
Sağladığı Değer
min 2,2 ± 0.07
≥1500
≤(%) 3
≥50.000
≥1500
≤50 x D
≥300
≤(%)0.2
≤2.1 ± 0.1
—50≤ ≤+150
≤ -2,3
≤ 0.05
Test Yöntemi
ASTM D 3916
ASTM D 3916
ASTM D 3916
ASTM D 3916
ASTM D 3916
DIN 53 455
DIN 53 472
ASTM D 885
ASTM D 696
47 / 126
b) Kablo Çekirdeği
Merkez elemanın çevresinde dairesel bir sıra oluşturan tüplerin ve plastik dolguların dağılmasını önlemek için kablo
çekirdeği polyester yassı iplikle (ters yönde çift iplik) kablo boyunca sarılacaktır. FİRMA, kablo çekirdeğinin
dağılmasını önlemek için, kullanılacak konstrüksiyonla ilgili olarak değişik öneride bulunabilecektir.
1.6
Kablo Dolgu Maddesi
a)
Fiber optik kablo çekirdeğinde bulunan merkez eleman ile fiber tüplerin arasına boşluk kalmayacak şekilde
uygun bir yöntemle dolgu maddesi ile doldurulacaktır. Dolgu maddesi tüp renklerini bozmayacak ve gözle net
seçilmesini engellemeyecektir.
b)
Homojen olacak ve içinde hava kabarcığı veya herhangi bir yabancı madde bulunmayacak, kabloyu oluşturan
diğer malzemelere olumsuz etkisi olmayacaktır.
c)
Zamanla elektriksel, fiziksel ve kimyasal özelliğini yitirmeyecektir.
d)
İnsan sağlığını ve çevreyi olumsuz etkilemeyecek ve rahatsız edici kokusu bulunmayacaktır.
e)
Dolgu maddesi ile doldurulmuş kabloların, tam olarak doldurulup doldurulmadığının belirlenmesi için su
sızdırmazlık testi yapılacaktır.
f)
Kullanılacak dolgu maddesi aşağıdaki özelliklerde olacaktır.
Özellikleri
Birimi
Sağladığı Değer
Test Yöntemi
Damlama noktası (Drop point)(24 saat)
(°C)
Drip noktasına uygun
IEC 811.5.1 B
Drip noktası (Drip point)(24 saat)
(°C)
≥80
REA PE 39
Alevlenme noktası
(°C)
≥230
ASTM D 92
Koni Batması (25 °C)
(0.1 mm)
50-70
ASTM D 937
Yağ ayrışması (50 °C)
(mm)
≤5
IEC 811 5.1.B
PE nüfuz değeri
Dielektrik katsayısı
Hacimsel direnç
Kayıp faktörü
(%)
<15
IEC-538-B
(MHz)
≤2.3
ASTM D 150
(Ω x cm)
(1 MHz)
Korozivite
12
>10
≤15 x 10
ASTM D 150
Korozyon olmayacak
IEC-811-5-1
<5
ASTM D 150
Pozitif
IEC 811.5.1
Renk
Aşınma
ASTM 257
-4
1.7
Aramid İplik
a)
Kablo çekirdeğinin üzerine kablo boyunca tek parça yüksek modüllü, Aramid iplik kullanılacaktır.
b)
Aramid iplik, 12-72 FO kabloda en az 2,5 gr/metre, 96-216 FO kabloda en az 3,5 gr/metre, 4 FO kabloda en az 3
gr/metre, olacaktır. Aramid iplik aşağıdaki özellikleri sağlayacaktır.
Özellikleri
Yoğunluk
Kopma kuvveti
Kopma uzaması
Esneklik katsayısı
c)
Birimi
3
g/cm
(N/mm²)
(%)
(KN/mm²)
Sağladığı Değer
1.44
>2000
≥2.5
≥100
Test Yöntemi
ASTM D 885
ASTM D 885
ASTM D 885
ASTM D 885
Aramid iplik, homojen olarak fiber tüpler çevresine sıcak yapıştırmalı şekilde sarılacaktır.
48 / 126
d)
Yapışkan; insan sağlığını ve çevreyi olumsuz etkilemeyecek, içinde hava kabarcığı veya herhangi bir yabancı
madde bulunmayacak, homojen olacak ve rahatsız edici kokusu olmayacaktır. Yapışkanın kabloyu oluşturan
diğer malzemelere olumsuz etkisi olmayacak, zamanla elektriksel, fiziksel ve kimyasal özelliğini
kaybetmeyecektir.
e)
Aramid için kullanılan yapışkan aşağıdaki özelliklerde olacaktır.
Özellikleri
Yumuşama Noktası
Akışkanlık(170°C)
Akışkanlık (190°C)
İçerdiği su
Birimi
(°C)
(mPas)
(mPas)
(%)
Sağladığı Değer
≥100
≥20.000±4.000
≥9.500±2.000
≤0.10
Test Yöntemi
ASTM E 28
ASTM D 3236
ASTM D 3226
DIN 53 495M3
1.8 Ondüle Çelik Bant Zırh
a)
Kablolar için ondüleli, iki yüzü polietilen filmle kaplı, kablo çapına uygun genişlikte, tek parça, homojen dış kılıfın
altında ve aşağıdaki özelliklerde çelik bir şerit kullanılacaktır.
Özellikleri
Birimi
(mm)
Kalınlık
2
Sağladığı Değer
0.155±0.015
Test Yöntemi
ASTM A 623 M
Kopma kuvveti
(N/mm )
≥300
ASTM E 6892
Kopma uzaması
(%)
≥15
ASTM E 6892
Kaplama kalınlığı
(mm)
0.05±0.01
ASTM A 623 M
Kaplamanın soyulma kuvveti
(N/mm)
≥4
ASTM A 6892
DC direnci
(Ω x km)
≤40
TS 3930
b)
Ondüle çelik bant zırh, elektrolitik krom kaplama, ASTM A 623 M, tip MR,T3 standardında olacaktır.
c)
Bozuk Ondüle çelik bant zırh yeniden kullanılmayacaktır.
d)
Ondüle çelik bant zırh; tanımlanan özellikleri karşılamak kaydıyla yalnızca lazer kaynağı ile birleştirilebilecektir.
e)
İki yüzü polietilen filmle kaplı ondüle çelik bant zırh uygun biçimde kablo boyunca su sızdırmazlığı sağlayacaktır.
Kablo boyunca iki yanı en az 5 mm genişlikte üst üste katlanmış ve her noktada düzgün bindirilmiş bir tüp
oluşturacaktır.
f)
Ondüle çelik bandın dış yüzü kablonun dış kılıfına gelecek ve üst üste gelen yerler kolayca ayrılmayacak şekilde
uygun bir yapıştırma yöntemiyle birleşmiş olacaktır.
g)
Ondüle çelik bandın kablo boyunca elektriksel devamlılığı olacaktır.
h)
Fiber optik kablolarda dış kılıfla ondüle bandı soymak amacıyla, ondüle bandın altına karşılıklı iki adet, kablo
boyunca (düz) tek parça Ripcord tipi iplik konulacaktır. Soyma ipi aşağıdaki özellikleri sağlayacaktır.
Özellikleri
Kopma kuvveti
Kopma uzaması
Esneklik katsayısı
Birimi
2
(N/mm )
(%)
2
(kN/mm )
Sağladığı Değer
≥300
≥3
≥70
Test Yöntemi
ASTM D 885
ASTM E 885
ASTM D 885
1.9 Polietilen Dış Kılıf
a)
Ondüle çelik bant zırh geçirilmiş kablo özü üzerine, UV ‘ye karşı direnç özelliğine sahip (UV direnç malzemesi
katkılı) natürel polietilen, rafineri şartlarında üretilmiş ve daha sonra yeraltı kablo için portakal (RAL 2008)
49 / 126
renkli, havai kablo için siyah renkli masterbach ile renklendirilmiş ve 1.14.g maddesinde belirtilen özellikleri
sağlayan PE bir kılıf geçirilecektir.
b)
Dış Kılıf et kalınlığı (zırh ile birlikte),12-216 FO kablolarda 2,2 ±0.2 mm, 4FO kablolarda ≥ 1,8 mm olacaktır.
c)
Havai kabloda ayrıca askı teli içinde yukarıdaki maddelerde belirtildiği şekilde PE bir kılıf geçirilecektir. Kablo
kılıfı ile askı teli kılıfı arasındaki körünün genişliği ve yüksekliği 2.8±0.2 mm olacaktır.
d)
İç Kılıf et kalınlığı, 4FO kablolarda ≥ 1,1 mm olacaktır.
1.10 Askı Teli
a)
Havai kablolarda askı halatında kullanılmak üzere sıcak daldırma yöntemi ile galvanizlenmiş TSE 730’a uygun
dairesel kesitli çelik teller kullanılacaktır.,
b)
Yüzeyi zedelenmiş olmayacak ve yüzeyinde çizik, çatlak, oksitlenme, yağ, pas, çapak gibi yabancı maddeler ile
galvaniz damlaması, çinko oksit ve çinko klorür kalıntısı bulunmayacaktır.
c)
Askı telleri kablo boyunca tek parça olacak olup, her türlü kaynak vb. yöntemle eklenmemiş olacaktır.
d)
Askı teli; bir çelik tel ortada ve aynı özellikte 6 adet tel ortadaki telin çevresinde olacak şekilde boşluksuz ve
bindirmesiz olarak bükülecektir. Özellikleri aşağıdaki şekilde olacaktır. D: halat çapı, d: tel çapı (mm)
Özellik
Çapı
Kopma kuvveti
Kopma uzaması
Yük altında %1 uzamadaki
gerilme
Çinko kaplama miktarı
Adım aralığı
e)
Birimi
(mm)
2)
(kgf/mm
(%)
(kgf/mm
(g/m
2)
2)
Sağladığı Değer
1,75±0,03
≥ 147
≥3
Test Yöntemi
ASTM D 638
ASTM D 638
ASTM D 885
≥ 133
≥ 200
16xD
ASTM A 90
Çelik tel 3xd (nominal) çaptaki bir silindir üzerine 15 devir/dakika’dan az bir hızla en az iki tur sarıldığında tel
yüzeyi üzerindeki çinko kaplamada çatlama, pullanma ve el sürülünce dökülme olmayacaktır.
1.11 Fiber Optik Kablo
Üretimi tamamlanmış FO kablo aşağıdaki özellikleri sağlayacaktır.
Test
Test Standartı
Tanımlanmış Değer
1.5 * W [N], (min. 2700)
4 FOY – Min.1200
0.5 * W [N], (min. 900)
4 FOY-Min.700
4000 N / 100 mm, (maks.
15xD)
30 Nm, 3 darbe, R= 300 mm
5Nm,3 darbe,R= 12.5 mm
Maks. montaj gerilimi
IEC 60794–1-2-E1
Maks. işletme gerilimi
IEC 60794–1–2-E1
Radyal Mukavemet
IEC 60794–1–2-E3
Darbe
IEC 60794–1–2-E4
Burulma
IEC 60794–1–2-E7
100N, +/- 180°, 10 tur
Tekrar Bükme
IEC 60794–1–2-E6
R=20x D, 100 N, 35 tur
Kablo bükme
IEC 60794–1–2-E11
R=20x D, 4 dönüs, 3 tur
Klima
IEC 60794–1–2-F1
Su sızdırmazlık
IEC 60794–1–2-F5B
-40°C ile +70 °C arası
numune=1m, su
sütünu=1m
Yeterlilik Şartı
∆α çevrilebilir, fiber
uzaması ≤0.33%
fiber uzaması yok, ∆α≤
0.05 dB
∆α≤ 0.05 dB, hasar
olmayacak
∆α≤ 0.05 dB testten sonra
∆α≤ 0.05 dB, hasar
olmayacak
hasar olmayacak
∆α≤ 0.05 dB, hasar
olmayacak
∆α≤ 0.05 dB/km
24 saat sonra su
sızdırmazlığı
50 / 126
o
o
o
o
o
o
Nakliye & Depolama
: -40 C ile +70 C arası
Montaj
: -20 C ile +60 C arası
Çalışma
: -40 C ile +70 C arası
1.12 Kablo Tanım İşareti
a)
Fiber optik kabloların tanınması için dış polietilen üzerine, metrede 1 adet 4 mm yüksekliğinde sıcak baskı
yöntemiyle aşağıdaki yazı ve işaretler yazılacaktır.
<M ETRE> m
AB010800081<TURKSAT> <FİBER SAYISI> FO OPTİK KABLO <ÜRETİCİ FİRMA ADI>
<M ETRE> m.
b)
Tanıtıcı işaretler; siyah boya ile yazılacak, bu yazı ve işaretler atmosfer koşullarına dayanıklı olup kolayca
kazınmayacak, kimyasal maddelerle kolayca çıkmayacaktır.
c)
Kablonun alt ve üst uçlarında en az 1 'er metre ölçü boyu bırakıldıktan sonra 0000 dan başlayarak her metrede
bir metraj rakamı basılacaktır.
d)
Kablo öz üzerine kablo boyunca (üretici firmayı tanıtmak amacıyla) baskılı kısım dış kılıfa bakacak şekilde, firma
adı, üretim tarihi (ay ve yıl), kablo tipi, öz numarası ve TÜRKSAT A.Ş. yazılı polyester şerit konacaktır. Bu yazı
30~40 cm’yi geçmeyecektir
1.13 Ambalajlama
a) Makara Yapısı
Üretimi tamamlanmış kablolar, ağaçtan veya geri dönüşü olan demir, fiber vb. makaralara sarılacaktır.
Makaraların göbeğinde 75-85 mm çapında bir mil deliği ve bu mil deliği çevresinde de metal çember bulunacaktır.
Makara yanaklarını birbirine bağlayan civatalar makara yüzeyinde çıkıntı yapmayacak şekilde olacaktır. Makaranın
tambur çapı en az 50 cm olacak ve üzerine uygun bir kağıt veya hava kabarcıklı naylon sarılacaktır. Makaraların iç
yanakları kablo dış kılıfını zedelemeyecek şekilde düzgün bir yapıda olacaktır. Makaralara 2.000 ± (%5) metre
boyundaki FO kablolar sarılacak ve FO kabloları dışardan gelecek darbelere karşı koruyacak yapıda olacaktır.
Makaranın yan kenarlarından bir tanesinin iç yüzeyine ağaçtan yapılmış Şekil 6’deki tabakalardan biri tutturulacaktır.
Fabrika kabulünden sonra kabloların üzeri renksiz naylon ile düzgün olarak sarılacaktır. Teslim edilecek kablo sarılmış
makaraların üstü yan yana aralıksız konulacak en az 3 cm kalınlığında tahtalarla sağlam bir şekilde kapatılıp 2 yerden
çelik çemberle sarılıp çivilenecektir.
b) Makaralarda Kablonun Durumu
Kablonun üst ucu kırmızı, alt ucu ise yeşil bant sarılarak işaretlenecektir. Kablonun alt ve üst ucundan, ölçü ve
muayene yapabilmek amacıyla 1 metre kablo (bu uzunluk kablo boyuna dahil edilmeyip) bırakılacak ve makara iç
yanağına uygun şekilde tespit edilecektir. Kablonun üst ve alt ucu ölçü ve muayeneye elverişli bir konumda tespit
edilecek ve bu konum makaranın dışında boya ile işaretlenecektir.
c) Kablo Uçlarının Kapatılması
Kablo içine nemin girmesini önlemek için; muayeneleri biten kabloların uçları hemen kapatılacaktır. Kapama; sağlam
yapılı kauçuk, veya PVC’den tüp başlıkları, sıkıca geçirilerek veya ısıyla büzüşebilen tek ağzı açık hortumla
yapılacaktır. Seçilen yöntemde kablonun dış çapında önemli bir genişleme olmayacaktır. Fiber Optik Kablolar için her
bir makara ile 2 adet yedek kapama kepi makaranın iç yanağına tutturularak verilecektir.
51 / 126
d) Makaralar Üzerinde Bulunacak Bilgiler
Makaranın iki dış yanağı üzerine siyah boya ile (iyi kalitede, atmosfer şartlarına dayanıklı) düzgün şekilde aşağıdaki
bilgi ve işaretler yazılacaktır. Bu yazının simetriğine de aynı puntoda Firma adı yazılacaktır.
TÜRKSAT AŞ.
…....... FİBER OPTİK KABLO
MAKARA NO
:………….
KABLO UZUNLUĞU
:………….
KABLO TİPİ
:………….
ÜRETİM YILI
:………….
ÜRETİCİ ADI
:………….
BRÜT AĞIRLIK
:………….
Kablonun makaradan açılma yönünü gösteren; kenarlara yakın, yaklaşık 30 cm boyunda, 65 cm çapında karşılıklı iki
ok olacaktır. Kenarlara yakın bir yerde oklara 90° olacak şekilde 8 cm lik puntoda aşağıdaki bilgiler yazılacaktır.
Makara numaraları için 11 karakterden oluşacak bir kod kullanılacaktır. Bu yönteme göre aşağıdaki örnekte olduğu
gibi numaralamalar birbirini izleyecek şekilde verilecektir.
Örnek:
AB firmasının 2008 yılı Ocak ayında üretmiş olduğu 8. Öz’den yapılmış ilk kablo
AB
01
08
0008
1
Özden üretilmiş kablo numarası(1)
8.Öz numarası
Üretim yılının son iki basamağı
Üretim ayı (İki basamak)
Üretici firma adının ilk iki harfi
Paslanmaz 15 x 10 cm² ölçüsünde metal bir plakaya aşağıdaki bilgiler tam olarak yazılarak makaranın her iki yanağına
çakılacaktır.
TÜRKSAT A.Ş.
KABLO TİPİ
KABLO UZUNLUĞU
MAKARA AĞIRLIĞI (BRÜT)
KABUL TARİHİ
MAKARA NUMARASI
……….FO
…….mt.
…………..kg
…../…./20….
(FİRMA ADI)
52 / 126
1.14 Fiber Optik Kablo Kabul Muayene Testleri
a) Optik Test
1310 nm ve 1550 nm. dalga boyunda fiber optik kablolardaki kilometrik kayıplar ölçülecek, kabloda her hangi bir
yansıma olup olmadığı kontrol edilecektir.
b) Su Sızdırmazlık Testi
Boylamasına su sızdırmazlık testi için üretimi tamamlanmış kablodan yaklaşık 1.3 m boyunda düzgün bir örnek kablo
kesilecektir. Örnek kablo dış kılıfının üzerine kablo eksenine paralel düzgün ve belirgin bir çizgi çizilecektir. Örnek
kablo kendi çapının 15 katı çapında silindirik bir tambur üzerine, işaret çizgisi belli bir yöne gelecek şekilde
sarılacaktır. Kablo tambur üzerinden çıkarılıp doğrultulacak çizgisi 180° ters yöne gelmek üzere kablo tamburu
üzerine yeniden sarılacak tambur üzerinden çıkarılıp doğrultulacaktır. Bu sarma açma işlemleri aynı örnek kabloya bir
kere daha uygulanacaktır.
Örnek kablonun her iki ucundan 15'er cm.lik birer parça kablo çok keskin bir testere ile kesilip atılacaktır. Ortada
kalan 1 metrelik kısım düzgünleştirilerek ve aşağıdaki test düzeneğine bağlanacaktır. 0°C≤ ≤ +30 °C sıcaklıkta 24 saat
süreyle kablo, üstü açık hava basıncı altında tutulan 100 cm.lik su sütunu kabloya bağlanacaktır. Su, tek hareketle ve
ani bir uygulama ile kabloya uygulanacaktır.
Aynı kablonun diğer ucundan da bir örnek alınarak bu test yapılır. Test süresi sonunda kablo örneği açılarak UV ışıkla
bakılır. FO kablonun diğer (ondüle bant, fiber tüp ve kablo özünde) ucunda, su belirtisi var ise test olumsuzdur.
Su sızdırmazlık test düzeneği
c)
Soyulma testi
Polietilen Soyulması
Ondüle Çelik bant zırhın yapışık olduğu polietilene aşağıdaki deney yapılacak ve buradan elde edilen polietilen kılıfın
soyulma kuvveti >8 N/mm. olacaktır.
Soyulma testi TSE 3930'a göre yapılacaktır. Kablo boyunca kenarları paralel olarak kesilecek örnekler, 150 mm.
boyunda, 14±2 mm genişlikte olmalıdır ve kenarları keskin bir bıçakla bir kerede kesilmelidir. Test parçalarında
Ondüle Çelik bant zırh üst üste geldiği kısımlar bulunmayacaktır.
Test için, elektrikle çalışan bir "gerilme deneyi ölçme makinesi" kullanılacak, makinenin çenelerinin uzaklaşma hızı
100–125 mm./dak. arasında olacaktır.
Örneğin iki ucundan yaklaşık 50 mm’lik bir bölümü soyulur. Üst çeneye Ondüle Çelik bant zırh, alt çeneye de
polietilen tespit edilerek makine çalıştırılır. İki parçayı ayırmak için gerekli kuvvet her 8 saniyede bir olmak üzere
53 / 126
(otomatik olarak) 7 değer alınır. Bu işlem 5 örnek için yapılır. Her bir örnek için alınan değerlerden en düşük ve en
yüksek değerleri atılır, diğer değerlerin aritmetik ortalaması alınır. Bu değer; örneğin soyulma (ayrılma) kuvvetidir.
Soyulma kuvveti, polietilen kılıfın kopma kuvvetinden büyük ise soyulma sırasında polietilen kopabilir. Bu durumda
polietilen kopma kuvveti, soyulma kuvveti olarak alınacaktır.
Çarpma Etkisi (Crush Strength)
100 N'dan başlayıp 30 sn'de bir 250 N aralıklarla 4000 N’a kadar devam edecektir. Bu işlem sırasında hiç bir fiberde
zayıflama olmamalıdır. Çarpmaya karşı zırh 5 kN'a dayanmalı Çarpma etkisi-zayıflama ve % 20 bozulmanın olduğu
yük gösterilecektir.
d) Kablo Sıcaklık Testi
Fiber Optik kablonun Sıcaklık testi IEC 794.1.F1 yöntemine göre yapılacaktır. -40°C ile 70°C arasında değişen bir
sıcaklıkta aşağıda belirtilen sıcaklık-zaman grafiği 2 periyot olarak sabit sıcaklıkta 36 saat bekletilerek yapılacaktır. Bu
test sırasında kablonun bulunduğu ortamın geçişlerinde ve sabit sıcaklıklarda 8 saat ara ile kablonun optik ölçüleri
yapılacaktır. Test sonucunda kablonun dB/km zayıflamasındaki değişim %10'u geçmeyecektir.
T (oC)
70 oC
0 oC
t1= 36
t2= 36
t (saat)
- 40 oC
Not: Fiber optik kablo klimaya makarasız olarak bırakıldığında t1 ve t2 süreleri 12 saat olarak uygulanır.
e) Germe Kuvveti Testi
Germe Kuvveti testi, IEC 60794-1-2 E1 göre kablo üzerine, tüm kablo tiplerinde ayrı ayrı “1.5xW [N]”, (min. 2700)
formülü sonucu kadar kuvvet uygulanarak test yapılır. Test yönteminde; zayıflama miktarındaki değişimi (∆dB) ve
fiber uzaması (∆f) değerlerini bir tek grafik üzerinde görülebilecek şekilde bilgisayarlı ve tam otomatik olarak elde
edilmiş kuvvet-zayıflama ve kuvvet-fiber uzaması grafikleri verilecektir. Maksimum fiber uzamasının %0.33 değerini
aşmaması gerekir. Test aşağıda gösterilen düzenek veya benzeri ile yapılacaktır.
54 / 126
f)
Polietilen Testleri
Üretimde kullanılan polietilenlerin teknik özellikleri sağlayıp sağlamadığı kontrol edilecektir.
g) Üretilmiş Fiber Optik Kablo Dış Kılıf Polietilen Testleri
Aşağıda belirtilen özellikler üretilmiş kabloda PE testlerini göstermekte olup bu testlerin tanımladığı koşul ve
değerleri sağlayan standartlar da test için kullanılabilecektir.
Özellikleri
2
Sağladığı Değer
Test Yöntemi
Kopma kuvveti
(N/mm )
> 19.3
ASTM D 638
Kopma uzaması
(%)
> 400
ASTM D 638
(%10 Igepal C-630)
( >48 saat)
2/10 hata
ASTM D 1693
(< -75°C)
2/10 hata
ASTM D 746
(g/cm )
0.926≤ x ≤0.940
ASTM D 792
(dak)
> 25
IEC 811.4.2.B
E.S.C.R
Soğukta kırılganlık
Yoğunluk (Metot A)
Oksijen Induction Zamanı(O.I.T)
testi(200°C)
h)
Birimi
3
Üretimde kullanılan fiber glass merkez elemanı için tanımlanan teknik özelliklerin sağlanıp sağlanmadığı test
edilecektir.
55 / 126
i)
Parametre Testleri
Fiber Optik Kablonun imalatında kullanılan elyafların aşağıda belirtilen testleri; üretim sırasında veya kablo üreten
firmanın stoklarında bulunan ürünler üzerinde uluslararası standardında tanımlandığı şekilde tüm masraflar firmaca
karşılanmak şartıyla TÜRKSAT heyetince Tablo-1'e göre kontrol edilecektir.
PARAMETRELER
Mod alan çapı (Mode field diameter)
Zayıflama(dB/km)
Test Yöntemi
IEC 60793-1-45 / ITU-T G.650.1 Methot.5.2.1
IEC 60793-1-40 / ITU-T G.650.1 Methot.5.4.1&5.4.2
Kromatik saçılma (Chromatic dispersion)
IEC 60793-1-42 / ITU-T G.650.1 Methot.5.5.1
Dalga boyu kesimi (Cut-off Wavelenght)
IEC 60793-1-44 / G.650.1 Methot.5.3.1&5.3.3
Core çapı
Cladding çapı
Core-Cladding eş merkezlik hatası
IEC 60793-1-20 / ITU-T G.650.1 Methot.5.2.1
Core ovalliği
Cladding ovalliği
Coating çapı
Coating ovalliği
IEC 60793-1-21 / ITU-T G.650.1 Methot.5.2.1
Coating-Cladding eş merkezlik hatası
Bükülme kaybı
IEC 60793-1-47
Deneme gerilme kuvveti
IEC 60793-1-30
Sıcaklılık Bağımlılığ
IEC 60793-1-52
Suya Daldırma
IEC 60793-1-53
Sıcakta Yaşlandırma
IEC 60793-1-51
56 / 126
EK-1 TABLO1
OPTİK VE GEOMETRİK ÖZELLİKLER
Işık Dalga Boyu
Zayıflama*(maksimum)
Mode alan çapı (mode Field
Diameter)
Kromatik Saçılma
Örtü tabakanın (cladding) çapı
Core eşmerkezlilik hatası (Core
concentricity error)
Saçılmanın 0 noktaları
Örtü tabakanın (cladding) ovalliği
Birinci kaplamanın (coating) çapı
Dalga boy kesimi (λcc)(kabloda Cut
Off Wavelenght)
Bükülme kaybı; (30 mm yarıçaplı
makaraya 100 tur sarılı iken kayıp)
PMDq (kabloda)
BİRİMİ
nm
dB/km
ITU-T G652.D
FİBER KABLODA
1310
1550
≤0.36
≤0.22
FİBER ELYAFTA
1310
1550
≤0.35
≤0.21
µm
9.2±0,4
10.3±0,5
9.2±0,4
10.3±0,5
ps/(nm x km)
µm
≤3.5
125±0.7
≤17
≤3.5
125±0.7
≤17
µm
<0.6
<0.6
nm
%
µm
1300≤ ≤1324
<1
250±10
1300≤ ≤1324
<1
250±10
nm
<1260
dB
<0.05
Ps/√km
≤0.2
≤0.2
Not:(*) 1310 nm; 1285≤ ≤1330nm aralığını,1550 nm; 1525: ≤ ≤1575nm. dalga boyu aralığını kapsamaktadır.
Bu değerler IEC standartlarında belirtilen test yöntemlerine göre kontrol edilecektir.
1383 nm de Hidrojen yaşlanması yapıldıktan sonraki zayıflama ≤ 0.32 dB/km. olacaktır. Bu test sırasında sıcaklık
değişimindeki zayıflamanın değişimi ≤ 0.05 dB/km olacaktır.
Mekanik Özellikler
Birimi
İstenilen Değerler
Deneme gerilme kuvveti (Proff Test)
N
8.4
Deneme gerilmesi (Proff Test strain)
%
1.00
Depolama ve Taşıma sıcaklığı
°C
- 40≤ ≤+80
Tesis sıcaklığı
°C
- 5≤ ≤+50
Not: Bu değerler IEC standartlarında belirtilen test yöntemlerine göre kontrol edilecektir.
57 / 126
EK-2 TABLO2
A)
12 FİBERLİ FO KABLODA RENK SIRALAMASI
SIRA NO
FİBER TÜP RENGİ
1
KIRMIZI
RAL 3000
2
SARI
RAL 1021
3
YEŞİL
RAL 6018
4
5
6
BEYAZ RAL 9001
BEYAZ RAL 9001
BEYAZ RAL 9001
SIRA NO
1
2
3
4
5
6
7
8
9
10
11
12
BOŞ
BOŞ
BOŞ
FİBER RENKLERİ
KIRMIZI
SARI
YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
NATUREL
BOŞ
BOŞ
BOŞ
SIRA NO
FİBER RENKLERİ
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
KIRMIZI
SARI
YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
NATUREL
B) 24 FİBERLİ FO KABLODA RENK SIRALAMASI
SIRA NO
FİBER TÜP RENGİ
1
KIRMIZI
RAL 3000
2
SARI
RAL 1021
3
YEŞİL
RAL 6018
4
MAVİ
RAL 5015
5
MENEKŞE
RAL 4005
6
BEYAZ
RAL 9001
58 / 126
C) 96 FİBERLİ FO KABLODA RENK SIRALAMASI
SIRA NO
FİBER TÜP RENGİ
1
KIRMIZI
RAL 3000
2
SARI
RAL 1021
3
YEŞİL
RAL 6018
4
MAVİ
RAL 5015
5
MENEKŞE
RAL 4005
SIRA NO
FİBER RENKLERİ
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
59 / 126
6
KAHVERENGİ
RAL 8003
7
SİYAH
RAL 9004
8
BEYAZ
RAL 9001
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
D) 144 FİBERLİ FO KABLODA RENK SIRALAMASI
216 FO kablonun 2. Katmanındaki renk sıralaması uygulanacaktır.
60 / 126
E)
216 FİBERLİ FO KABLODA RENK SIRALAMASI
1. İLK KATMAN
SIRA NO
FİBER TÜP RENGİ
1
KIRMIZI
RAL 3000
2
SARI
RAL 1021
3
YEŞİL
RAL 6018
4
MAVİ
RAL 5015
5
MENEKŞE
SIRA NO
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
FİBER RENKLERİ
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
61 / 126
RAL 4005
6
BEYAZ
RAL 9001
SIRA NO
FİBER TÜP RENGİ
50
51
52
53
54
55
56
57
58
59
60
71
72
205
206
207
208
209
210
211
212
213
214
215
216
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
SIRA NO
FİBER RENKLERİ
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
2. İKİNCİ KATMAN
7
KIRMIZI
RAL 3000
8
SARI
RAL 1021
62 / 126
9
YEŞİL
RAL 6018
10
MAVİ
RAL 5015
11
MENEKŞE
RAL 4005
12
KAHVERENGİ
RAL 8003
13
SİYAH
RAL 9004
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
63 / 126
14
TURUNCU
RAL 2008
15
PEMBE
RAL 3015
16
GRİ
RAL 7035
17
AÇIK YEŞİL
RAL 6027
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
S
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
64 / 126
18
BEYAZ
RAL 9001
131
132
133
134
135
136
137
138
139
140
141
142
143
144
AÇIK YEŞİL
NATUREL
KIRMIZI
SARI
YEŞİL
MAVİ
MENEKŞE
KAHVERENGİ
SİYAH
TURUNCU
PEMBE
GRİ
AÇIK YEŞİL
NATUREL
65 / 126
66 / 126
67 / 126
ŞEKİL-6
68 / 126
OPTİK ARA BAĞLANTI KABLOSU (PATCHCORD)
VE TERMİNSAYON SETLERİ (PATCH PANEL)
69 / 126
a)
Fiber elyaf tek modlu (single mode) ve ITU-T G.657 A2/B2 standartına uygun olarak üretilmiş olacaktır.
b)
Teknik özellikleri IEC 60793-2-50 B1.3 standartında tanımlanan optik fiberlerin teknik özelliklerini
karşılayacaktır.
c)
Optik ara bağlantı kablosu aşağıda belirtilen optik , geometrik ve mekanik özellikler karşılanacaktır.
ÖZELLİKLER
Işık Dalga Boyu
Zayıflama (maksimum)
Mode alan çapı (Mode Field Diameter)
Kromatik Saçılma
Örtü tabakanın (cladding) çapı
Core-Cladding Eşmerkezlilik Hatası
Coating-Cladding Eşmerkezlilik Hatası
Saçılmanın 0 noktaları
Örtü tabakanın (cladding) ovalliği
Birinci kaplamanın (coating) çapı
Dalga boy kesimi (λcc)
(kabloda Cut Off Wavelenght)
Bükülme kaybı;
 15 mm yarıçaplı makaraya 10 tur sarılı iken
1550nm de kayıp:
 10 mm yarıçaplı makaraya 1 tur sarılı iken 1550nm
de kayıp:
 7.5 mm yarıçaplı makaraya 1 tur sarılı iken 1550nm
de kayıp:
PMD Değeri (elyaf fiber ve kabloda)
BİRİMİ
nm
dB/km
µm
ps/(nm x km)
µm
µm
µm
nm
%
µm
1310
1550
≤0.35
≤0.2
9±1
10.3±0,5
≤3.5
≤17
125±0.7
≤ 0,6
≤ 12
1300≤ ʎ ≤1324
≤1
245±5
nm
≤ 1260
≤ 0,03
dB
≤ 0,1
≤ 0,5
Ps/√km
≤0.2
d)
Optik ara bağlantı kablosu üzerindeki kılıf yanıcı olmayacak, kablonun aleve dayanıklılık özelliği IEC 60332-1-2,
IEC 60332-3-24, IEC 60754-1, IEC 60754-2 ve IEC 61034-2 standartlarıına göre test edilecektir.
e)
Fiber elyaf üzerine sıkı tüp çekilmiş olacak ve sıkı tüp fiber boyunca homojen kalınlıkta olacaktır. Sıkı tüp,
sıyırıcılarla tek çekişte kolayca sıyrılacak ve sıyrılma sonunda fiber üzerinde temizlenemeyecek tortu
kalmayacaktır.
f)
Sıkı tüpün üzerine yeterli miktarda ‘Aramid iplik’ sarılmış olacak, dış kılıf LSoH ve renk RAL 1021 veya RAL 9001
renk kodunda olacaktır.
g)
Dış kılıf üzerinde, her metrede ve siyah renkte “ Kablo uzunluk bilgisi, fiber tipi ve fiber sayısı” yazılı olacaktır.
h)
Optik ara bağlantı kablosunun iki ucuda konnektörlü, konnektörler ise SC-UPC, SC-APC, veya E2000-UPC,
E2000-APC, tipinde olacaktır.
i)
Optik ara bağlantı kablo uzunlukları; 1m, 3m, 5m, 10m, 20m veya 30m olacaktır.
j)
Konnektörlerin ve U-Linklerin boyut ve toleransları aşağıdaki standartları karşılayacaktır.
Konnektör
SC Tipi Konnektör
E2000 Tipi
Konnektör
k)
Sağlanan Standart
IEC 61754-4-X
IEC 61754-15-X
Optik ara bağlantı kabloları, dış darbelerden hasar görmeyecek şekilde korumalı olacak, sevkiyatlarda,
depolamada, indirme ve bindirmede, kırılma, çatlama risklerine karşı orijinal paketleri içerisinde olacaktır. Optik
70 / 126
ara bağlantı kabloları ayrı ayrı ambalajlanacak ve ambalaj üzerinde RoHS uyumluluğunu gösteren etiket ile
birlikte Türksat adının, Üretici firma adının, Seri numarasının, Üretim tarihinin yer aldığı etiket bulunacaktır.
l)
U-LINK lerin sağlayacağı değerler ve test standartları aşağıdaki şekilde olacaktır.
Özellikleri
Sağladığı Değer
Test Yöntemi
U-Link Adaptör geçiş kaybı
≤ 0,3 dB
IEC-61300-3-42
Geri dönüş kaybı (APC)
> 55 dB
IEC-61300-3-6
Geri dönüş kaybı (UPC)
> 50 dB
Kullanım sayısı
> 1000
m)
U-LINK adaptörlerin fiber yatakları Zirconia Seramik olacaktır. Adaptörlerin uçlarında içeriye toz girmesini
önlemek için bas-tak tipi plastik kapaklar olacaktır.
n)
U-LINK adaptörlerin ısıya dayanıklılık özelliği UL 94-v0 standartına göre test edilecektir.
o)
Terminasyon setleri 12, 24, 48 ve 96 Fiber kapasiteli olacak olup, sırasıyla 1U, 1U, 2U ve 4U boyutlarında 19”
olacaktır.
p)
Tüm terminasyon modüllerinin içinde kapasitesi kadar dublex ve/veya simplex SC/APC adaptörler, ek
koruyucular, ek kasetleri ( 12F kapasiteli) , kasetler üzerinde ek tutucular, modüle uygun uzunlukta ve simplex
900 mic., LSOH, beyaz veya sarı renkte G.657A2/B2 fiberli pig-tailler ile fiber yönlendiricileri ile giriş/ çıkış kablo
rakorları vb. dizaynın gerektirdiği tüm aksesuarlar eksiksiz olacaktır.
q)
Kullanılacak pigtailler, yukarıda belirtilen geometrik ve optik özellikleri sağlayacaktır.
71 / 126
FİBER OPTİK KABLO EK KUTULARI
72 / 126
a)
Havai ve yer altı ek kutuları aynı tipte ve ömrü en az 25 yıl olacaktır.
b)
Ek kutularında kullanılan ek kasetleri 12 fiberli veya katları şeklinde olacaktır. Ek kutusu içerisinde kapasitesi
kadar fiberi alabilecek kadar ek kaseti yer alacaktır.
c)
Ek kutuları; kablolarda T eki yapılabilmesi için fiber tüplerinin kesilmeden ve Sıyrılmadan en az iki tur rezerve
bırakılmasını sağlayacak yapıda olacaktır.
d)
Metal içeren FO kabloların topraklamasının sağlanabilmesi için ek kutusunun topraklama bağlantı ucu, kablo
içerisinde metal bağlantı yapılabilecek şekilde ek kutusu içerisindeki topraklama barasına tutturulacaktır. Aynı
zamanda merkez elemanların mekanik olarak bağlantısı yapılabilecektir.
e)
FO kablonun ek kutusuna tutturulması ısı ile büzüşebilen hortumla yapılacaktır.
f)
Ek kutusunun tabanında kablo çapına uygun 4 adet dairesel kablo girişi ve uzun kenarı 65 mm-75 mm olan ve
kablo çapına uygun bir adet oval giriş olacak ve ısı ile büzüşen hortumların montajına engel olmayacaktır.
g)
Ek kutusu kasetleri ve kapakları kolayca sökülüp takılabilecektir.
h)
Ek kutusunun gövdesi ile kapağı arasında sızdırmazlığı sağlamak amacıyla kullanılan conta zamanla kapak ve
gövdeye yapışmayacaktır.
i)
Ek Kasetleri; en az 75 cm boyunda fiberin rezerv edilebileceği yapıda olacaktır.
j)
Ek kaseti içerisindeki fiberin büklüme çapı 65 mm' den büyük ve bir kasette en az kapasitesi kadar ek koruyucu
yuvası olacaktır.
k)
Dolap içi (Dahili) ek kutuları için yukarıda belirtilen özelliklerde ek kasetleri kullanılacak olup, özel muhafaza
kutuları içerisinde monte edilecektir.
EK Kutusu İçerisinde Bulunacak ilave Malzemeler ve Miktarları
Türkçe kullanma kılavuzu
Montaj için 2 noktadan tutturma demiri
Fiber kabloların istavroz demirine tutturulması için karbon katkılı kablo bağı
Ek kutusu tabanı ile kapağı arasında kullanılan conta
Ek kaseti
Kaset tutturma bağı
Çatal mandal
15’er cm uzunluğunda ısıyla büzüşen hortum (iç ve dış kılıf kablo çaplarına uygun)
Fiber tüp tutturma bağı (her bir kaset için)
Alkollü temizleyici mendil
Nem alıcı
Zımpara
Isı ile büzüşebilen 6cm boyunda ek koruyucu (her bir kaset için)
3 kasetli ek kutusunda
6/12/18 kasetli ek kutusunda
Fiber tüp için hortum veya spiral (kablo ucundan kaset girişine kadar)
3/6 kaset için
12/18 kaset için
Fiber ve tüplerinin ayırt edilebilmesi için numara bant
Alüminyum kablo koruma bandı (10x15cm)
İstavroz demiri ve gerekli (cıvata, kablo bağı vb.) tutturma malzemeleri
Metalli kabloların topraklama için 30cm boyunda bakır kablo
2
Ek kutusu ile istavroz arasına topraklama bağlantısı için 16 mm kesitli bakır kablo
1 adet
1 adet
En az 6 adet
1 adet
Kapasitesi Kadar
1 adet
1 adet
8 adet
6 adet
2 adet
2 adet
1 adet
Kapasitesi Kadar
Kapasitesi Kadar
1 takım
4 adet
1 takım
3 adet
1 adet
73 / 126
TEST ADI
Görsel Kontrol
Su sızdırmazlık
Isı değişimi
Çarpma
Düşme
UV Direnci
EK KUTUSUNA UYGULANACAK TESTLER
ŞARTLAR
TEST YÖNTEMİ
Ürünün gözle kontrolü
Test Sıcaklığı: 23±3 C°
Derinlik: 6 metre
Test Süresi: 5 gün
-40±2 C° ≤ ≤60±2 C°
Geçiş süresi: 1 saat
Bekleme süresi: 2,5 saat
Basınç: 40±2 kpa
Periyot: 20
Test Sıcaklığı: -15±3 C° (en az 4 saat)
Basınç: 40±2 kpa
Çarpma aleti: 1 kg ağırlığında çelik
top
Çarpma yüksekliği: 1 metre
Çarpma yeri: EK kutusunun en zayıf
noktası
Çarpma sayısı: 1adet
Test Sıcaklığı: 23±3 C°
Yükseklik: 2 metre
Düşme açısı: 60 °
Düşme sayısı: 1 adet
65 C° 8 saat
50 C° 4 saat
Sivri uçlu 313 nm dalga boyunda UV
ışık kaynağı kullanılacak
IEC 60512-2-1a
SONUÇ
Ek kutusu üzerinde çizik, kırık,
ezilme vb olmayacak
IEC 61300-2-32
Ek kutusu içerisine su
girmeyecek
IEC 61300-2-22
IEC 60068-2-14
Su sızdırmayacak
Çatlama, kırılma olmayacak
Maksimum kayıp değişim
<0,1 dB olacak
IEC 60512-5
Çatlama, kırılma olmayacak
Su sızdırmayacak
Yok
Çatlama, kırılma olmayacak
Su sızdırmayacak
IEC 61300-2-30
ISO 180
Gerilme kuvvetindeki
değişiklik %20 yi geçmeyecek
74 / 126
Ek Kutusu istavroz demiri:
75 / 126
KOAKSİYEL KABLO
TEKNİK ÖZELLİKLERİ
76 / 126
HARİCİ TRUNK KABLOLAR
Koşul
2.2 Bakır
3.3 Bakır
3.15 Alm.
4.22 Alm.
İç iletken
Bakır
Bakır kaplı alüminyum
İç iletken çapı (±0,1)
2.2 mm
3.3 mm
3.15 mm
4.22 mm
İç iletken direnci
20°C de
< 5 Ω/km
< 2,1 Ω/km
3,34 Ω/km
2,1 Ω/km
Dış iletken direnci
20°C de
< 2,8 Ω/km
< 1,9 Ω/km
1,94 Ω/km
1,39 Ω/km
Transfer Empedansı
5-30 MHz
< 0,9 mOhm/m
< 0,9 mOhm/m
Ortak kapasite
50 ± 5 pF/m
50 ± 5 pF/m
Karakteristik Empedans
75 ohm ±2
Yayılma hızı
%88
Ekranlama faktörü
30-1000 MHz
>120 dB
Dielektrik malzeme
Gaz enjeksiyonlu köpüklü polietilen
Kaynaklı Bakır Tüp
Kaynaklı Alüminyum
Dış iletken (Folyo)
(welded)
Tüp (welded)
*Jel Dolgu
Su Geçirmez Jel Dolgu
Dış kılıf (Sheath)
UV Dayanımlı Siyah Polietilen (PE)
Dış Kılıf Çapı
< 13 mm
< 18 mm
< 16 mm
< 20 mm
Tek Bükme Testi
R=10xD (Çap)
Tek bükme sonrası hasar olmayacak
Tekrarlı Bükme Testi
R=20xD (Çap)
10 tur sonrası hasar olmayacak
1m numune 1m su sütununda 24 saat bekletilecek
Su sızdırmazlık
ve su sızması olmayacak.
5 MHz
0,7
0,5
0,5
0,4
50 MHz
2,1
1,4
1,5
1,2
100 MHz
2,9
1,9
2,2
1,7
Zayıflama (dB/100m)
200 MHz
4,3
2,8
3,2
2,4
20°C de (+%10)
400 MHz
6,3
4,1
4,4
3,5
800 MHz
8,9
6,0
6,2
5,0
862 MHz
9,4
6,2
6,5
5,4
5-30 MHz
>26 dB
>30 dB
Return Loss
30-470 MHz
>26 dB
>30 dB
470-1000 MHz
>23 dB
>30 dB
 Havai kablolar için galvanizli çelik tel kullanılacaktır.
 *Havai kablolarda jel dolgu kullanılmayacaktır.
 CE Deklerasyon Belgeli
77 / 126
HARİCİ FİDER KABLOLAR
Koşul
TRS 2.2
Bakır Tel
1,62 ±0,02 mm
2,20 ±0,2 mm
< 8,60 Ohm/km
< 4,90 Ohm/km
< 10,20 Ohm/km
< 7,50 Ohm/km
< 2,5 Ohm/km
< 2,5 Ohm/km
75 ± 3 Ohm
50 ± 5 pF/m
> 83%
> 95 dB
Gaz Enejksiyonlu Köpüklü Polietilen
%100 Kapamalı Aluminyum Folyo İzoleye
Yapışık
> 55% Kalaylı Bakır
> 60% Kalaylı Bakır
Tellerden Örgü
Tellerden Örgü
APD Jel Malzeme ile dolgu
%100 Kapamalı Aluminyum Folyo
Dış Kılıfa Yapışık
UV Dayanımlı Siyah Polietilen
< 11 mm
< 13 mm
Tek bükme sonrası hasar olmayacak
10 tur sonrası hasar olmayacak
1m numune 1m su sütununda 24 saat
bekletilecek ve su sızması olmayacak.
1,2
0,7
2,9
2,2
4,2
3,1
6,1
4,6
8,5
6,7
12,7
9,9
> 23 dB
> 20 dB
> 18 dB
İç İletken
İç iletken çapı
İç İletken Direnci (20˚C)
Dış İletken Direnci (20˚C)
Transfer Empedansı (5-30MHz)
Karakteristik Empedans
Kapasitans
Yayılma Hızı
Ekranlama Faktörü (30-1000MHz)
İzolasyon
Dış İletken (1. Ekran)-Trishield
Dış İletken (2. Ekran)-Trishield
*Jel Dolgu
Dış İletken (3. Ekran)-Trishield
Dış kılıf (Sheath)
Dış Kılıf Çapı
Tek Bükme Testi
Tekrarlı Bükme Testi
R=10xD (Çap)
R=20xD (Çap)
Su sızdırmazlık
5 MHz
50 MHz
100 MHz
Zayıflama (dB/100m)
20°C de (+%10)
200 MHz
400 MHz
862 MHz
5 - 470 MHz
Return Loss
470 - 862 MHz
862 - 1000 MHz
 Havai kablolar için galvanizli çelik tel kullanılacaktır.
 *Havai kablolarda jel dolgu kullanılmayacaktır.
 CE Deklerasyon Belgeli
RG11
HARİCİ KABLO PE KILIF TESTLERİ
Özellikleri
Birimi
2
Sağladığı Değer
Test Yöntemi
Kopma kuvveti
(N/mm )
> 19.3
ASTM D 638
Kopma uzaması
(%)
> 400
ASTM D 638
(%10 Igepal C-630)
( >48 saat)
2/10 hata
ASTM D 1693
(< -75°C)
2/10 hata
ASTM D 746
(g/cm )
Min. 0.926
ASTM D 792
(dak)
> 25
IEC 811.4.2.B
E.S.C.R
Soğukta kırılganlık
Yoğunluk (Metot A)
Oksijen Induction Zamanı(O.I.T) testi(200°C)
3
78 / 126
Koşul
İç İletken
İç iletken çapı
İç İletken Direnci (20˚C)
Dış İletken Direnci (20˚C)
Transfer Empedansı (5-30MHz)
Karakteristik Empedans
Kapasitans
Yayılma Hızı
Ekranlama Faktörü (30-1000MHz)
İzolasyon
Dış İletken (1. Ekran)-Trishield
DAHİLİ KABLOLAR
RG11
Bakır Tel
1,62 ±0,02 mm
< 8,60 Ohm/km
< 10,20 Ohm/km
< 2,5 Ohm/km
Dış İletken (2. Ekran)-Trishield
Dış İletken (3. Ekran)-Trishield
Dış kılıf (Sheath)
Dış Kılıf Çapı
Zayıflama (dB/100m)
20°C de (+%10)
Return Loss
5 MHz
50 MHz
100 MHz
200 MHz
400 MHz
862 MHz
5 - 470 MHz
470 - 862 MHz
862 - 1000MHz
RG6
CMTS
CCS
Bakır Tel
1,02 ±0,02 mm
0,65 ±0,05 mm
< 94,00 Ohm/km
< 66 Ohm/km
< 28,50 Ohm/km
< 18 Ohm/km
< 5 Ohm/km
75 ± 3 Ohm
50 ± 5 pF/m
83% ± 3
> 95 dB
> 85 dB
Gaz Enejksiyonlu Köpüklü Polietilen
%100 Kapamalı Aluminyum Folyo İzoleye Yapışık
> 94% Kalaylı
> 55% Kalaylı Bakır
> %70 Aluminyum
Bakır Tellerden
Tellerden Örgü
Tellerden Örgü
Örgü
%100 Kapamalı Aluminyum Folyo
Dış Kılıfa Yapışık
Beyaz PVC
PVC
< 11 mm
< 7 mm
< 5 mm
1,2
2,2
3
2,9
4,5
8
4,2
6,5
11
6,1
9,0
15
8,5
13,4
22
12,7
19,5
32
> 23 dB
> 23 dB
> 20 dB
> 23 dB
> 18 dB
> 21 dB
 CE Deklerasyon Belgeli
79 / 126
PASİF RF MALZEME
TEKNİK ÖZELLİKLERİ
80 / 126
Insertion Loss (Max.) dB
Isolation (Out-Out Min.) dB
Return Loss (In-Out Min.) dB
Ekranlama Faktörü





DAHİLİ BÖLÜCÜLER
Mhz
2 way
3 way
4 way
15-1000
4
7
8
15-40
30
30
30
40-470
23
23
23
470-1000
22
22
22
15-1000
20
17
17
15-40
40-470
EN 50083/2- Çizelge 10 Class A
470-1000
Karakteristik empedans 75 ohm olacak,
En az 1.5 μm NiSn/Nickel/Sn/CuSn kaplı ve gövde ile aynı malzemeden F-Female konnektörlü
Gold/Silver/Tin/CuSn plated beryllium copper/ phosphorus bronze center conductor
Tüm portlarda DC Bloklama özelliği olacak,
CE Deklerasyon Belgeli olacak,
DATA-TV BÖLÜCÜSÜ (GALVANİK İZOLATÖRLÜ)
Mhz
TV
DATA
Insertion Loss (Min.) dB
5-85
35
5-1000
5
Insertion Loss (Max.) dB
110-1000
5
5-85
40
40
Isolation (Min.) dB
110-1000
20
20
Return Loss (Min.) dB
15-1000
18
18
15-40
Ekranlama Faktörü
40-470
EN 50083/2- Çizelge 10 Class A
470-1000
2120 V DC / 0,7 mA
Galvanik İzolasyon
230 V AC / 2 mA
 75 ohm karakteristik empedans,
 En az 1.5 μm NiSn/Nickel kaplı ve gövde ile aynı malzemeden F-Female konnektörlü,
 Gold/Silver plated beryllium copper center conductor or Tin Plated phosphorus bronze center
conductorTüm portlarda DC Bloklama özelliği olacak,
 CE Deklerasyon Belgeli,
HARİCİ BÖLÜCÜLER
Insertion Loss (Max.) dB
Isolation (Out-Out Min.) dB
Return Loss ( In-Out min.)
Mhz
2 way
3 way
15-40
4,2
6,5
40-470
4,5
7,5
470-1000
5,5
8,5
15-40
28
28
40-470
25
25
470-1000
23
23
15-1000
EN 50083/4 - Çizelge 1 Class B
15-40
Ekranlama Faktörü
40-470
EN 50083/2 - Çizelge 10 Class A
470-1000
Water Sealing Test
Salt Spray (Fog) Test
1m derinlikte su içerisinde 168 saat bekleme durumunda su girişi
olmayacak
1000 saat beklemede elektriksel performans düşümü ve metal
korozyonu olmayacak
81 / 126
1 metreden sert bir zemine 5 kez bırakılınca elektriksel ve fiziksel
bozulma olmayacak
15 PSI basınçta 1 dakika boyunca hava kaçağı olmayacak (Su
içerisinde test edilecek)
Drop Test
Air Leakage Test






75 ohm karakteristik empedans,
3,5/12 veya PIN (5/8”) konnektör girişi,
Aluminium alloy housing with weather-resistant powder coating
IPX8 (Ingress Protection) standardına uygun
Min. 15 Amper Power Passing,
CE Deklerasyon Belgeli,
DAHİLİ DAĞITICILAR
Insertion Loss (Max.) -dB
Tap Loss dB (Flatness ±1,5)
Isolation (Tap-Tap Min.) -dB
Isolation (Tap-Out Min.) -dB
Return Loss (In-Out Min.) -dB
Ekranlama Faktörü





Mhz
15-1000
15-1000
15-40
40-470
470-1000
15-40
40-470
470-1000
15-1000
15-40
40-470
470-1000
UNBALANCED
6 way
6
10-20
33
33
30
26
26
24
18
4 way
4
10-17
33
33
30
26
26
24
18
BALANCED
4 way
8 way
4
6
12
14
30
30
30
30
27
27
23
23
23
23
21
21
18
18
8 way
9
10-20
33
33
30
26
26
24
18
EN 50083/2 - Çizelge 10 Class A
75 ohm karakteristik empedans,
En az 1.5 μm NiSn/Nickel/Sn/CuSn kaplı ve gövde ile aynı malzemeden F-Female konnektörlü
Gold/Silver/Tin/CuSn plated beryllium copper/ phosphorus bronze center conductor
Tüm portlarda DC Bloklama özelliği olacak,
CE Deklerasyon Belgeli,
Insertion Loss
(Max.) -dB
Tap Loss (± 1.5) -dB
Isolation
Out-Tap Min. -dB
Isolation
Tap-Tap min. -dB
Return Loss In-Out
Return Loss Tap
Ekranlama Faktörü
Water Sealing Test
Salt Spray (Fog) Test
Drop Test
Air Leakage Test
Mhz
15-40
40-470
470-1000
15-1000
15-40
40-470
470-1000
15-40
40-470
470-1000
15-1000
15-40
40-470
470-1000
15-40
40-470
470-1000
2 WAY HARİCİ DAĞITICI
204
208
211
4
2
4,5
2,5
5
3,4
4
8
11
24
24
24
24
20
22
20
20
20
24
24
24
20
20
20
214
1,5
2,2
2,5
14
24
28
22
20
24
20
217
1,2
1,5
2,1
17
27
30
24
20
24
20
220
1
1,1
2
20
32
32
26
20
24
20
223
1
1,1
2
23
35
34
28
20
24
20
226
1
1,1
2
26
35
35
30
20
24
20
229
1
1,1
2
29
38
39
32
20
24
20
EN 50083/4 - Çizelge 1 Class B
EN 50083/2 - Çizelge 10 Class A
1m derinlikte su içerisinde 168 saat bekleme durumunda su girişi olmayacak
1000 saat beklemede elektriksel performans düşümü ve metal korozyonu
olmayacak
1 metreden sert bir zemine 5 kez bırakılınca elektriksel ve fiziksel bozulma
olmayacak
15 PSI basınçta 1 dakika boyunca hava kaçağı olmayacak (Su içerisinde test
edilecek)
82 / 126








75 ohm karakteristik empedans,
Giriş-Çıkış 3,5/12 veya PIN (5/8”) konnektör girişi,
Tap çıkışları en az 1.5 µm NiSn/Nickel kaplı ve Bakır/Pirinç malzemeden F-Female konnektörlü
Aluminium alloy housing with weather-resistant powder coating
IPX8 (Ingress Protection) standardına uygun
Min. 12 Amper Power Passing,
Opsiyonel olarak F portları (tap çıkışları) 1 Amper güç geçirebilir
CE Deklerasyon Belgeli,
Insertion Loss
(Max.) -dB
Tap Loss (± 1.5) -dB
Isolation
Out-Tap Min. -dB
Isolation
Tap-Tap min. -dB
Return Loss In-Out
Return Loss Tap
Ekranlama Faktörü
Water Sealing Test
Salt Spray (Fog) Test
Drop Test
Air Leakage Test








Mhz
15-40
40-470
470-1000
15-1000
15-40
40-470
470-1000
15-40
40-470
470-1000
15-1000
15-40
40-470
470-1000
15-40
40-470
470-1000
4 WAY HARİCİ DAĞITICI
408
411
414
3,5
2
4,5
2,2
5
4
8
11
14
25
27
25
27
20
22
25
25
25
25
25
25
20
20
20
417
1,6
1,8
3,5
17
28
30
23
25
25
20
420
1,1
1,4
3
20
31
31
23
25
25
20
423
1
1,2
2
23
33
33
25
25
25
20
426
1
1,1
2
26
36
36
30
25
25
20
429
1
1,1
2
29
40
40
32
25
25
20
EN 50083/4 - Çizelge 1 Class B
EN 50083/2 - Çizelge 10 Class A
1m derinlikte su içerisinde 168 saat bekleme durumunda su girişi
olmayacak
1000 saat beklemede elektriksel performans düşümü ve metal
korozyonu olmayacak
1 metreden sert bir zemine 5 kez bırakılınca elektriksel ve fiziksel
bozulma olmayacak
15 PSI basınçta 1 dakika boyunca hava kaçağı olmayacak (Su içerisinde
test edilecek)
75 ohm karakteristik empedans,
Giriş-Çıkış 3,5/12 veya PIN (5/8”) konnektör girişi,
Tap çıkışları en az 1.5 µm NiSn/Nickel kaplı ve Bakır/Pirinç malzemeden F-Female konnektörlü
Aluminium alloy housing with weather-resistant powder coating
IPX8 (Ingress Protection) standardına uygun
Min. 12 Amper Power Passing,
Opsiyonel olarak F portları (tap çıkışları) 1 Amper güç geçirebilir.
CE Deklerasyon Belgeli,
Insertion Loss
(Max.) -dB
Tap Loss (± 1.5) -dB
Isolation
Out-Tap Min. -dB
Isolation
Tap-Tap min. -dB
Return Loss In-Out
8 WAY HARİCİ DAĞITICI
Mhz
811
814
817
820
823
15-40
3,6
2
1,4
1,2
40-470
4,2
2,6
1,8
1,4
470-1000
5,3
3,7
3,2
2,5
15-1000
11
14
17
20
23
15-40
25
25
28
31
40-470
25
25
25
30
470-1000
20
20
22
26
15-40
23
23
23
23
23
40-470
23
23
23
23
23
470-1000
20
20
20
20
20
15-1000
EN 50083/4 - Çizelge 1 Class B
826
0,8
1,2
2
26
33
30
28
23
23
20
829
0,7
1,2
2
29
40
40
30
23
23
20
83 / 126
15-40
40-470
470-1000
15-40
40-470
470-1000
Return Loss Tap
Ekranlama Faktörü
1m derinlikte su içerisinde 168 saat bekleme durumunda su
girişi olmayacak
1000 saat beklemede elektriksel performans düşümü ve metal
korozyonu olmayacak
1 metreden sert bir zemine 5 kez bırakılınca elektriksel ve
fiziksel bozulma olmayacak
15 PSI basınçta 1 dakika boyunca hava kaçağı olmayacak (Su
içerisinde test edilecek)
Water Sealing Test
Salt Spray (Fog) Test
Drop Test
Air Leakage Test








75 ohm karakteristik empedans,
Giriş-Çıkış 3,5/12 veya PIN (5/8”) konnektör girişi,
Tap çıkışları en az 1.5 µm NiSn/Nickel kaplı ve Bakır/Pirinç malzemeden F-Female konnektörlü
Aluminium alloy housing with weather-resistant powder coating
IPX8 (Ingress Protection) standardına uygun
Min. 12 Amper Power Passing,
Opsiyonel olarak F portları (tap çıkışları) 1 Amper güç geçirebilir
CE Deklerasyon Belgeli,
Insertion Loss (Max.) -dB
Tap Loss (± 1.5) -dB
Isolation (Decoupling)
(Out Min.) -dB
“Isolation (Decoupling) (Tap
Min.) -dB”
Return Loss (Min.) –dB
Ekranlama Faktörü (Min.) -dB
Water Sealing Test
Mhz
15-1000
15-1000
AHTAPOT TİPİ HARİCİ DAĞITICILAR
210
215
220
310
3
2,1
1,8
4,6
10
15
20
10
315
2,9
15
15-1000
20
15-1000
30
15-1000
15-1000
Salt Spray (Fog) Test
Drop Test
Air Leakage Test




EN 50083/2 - Çizelge 10 Class A
320
2,3
20
410
5,9
10
415
3,6
15
420
2,7
20
15
75
1m derinlikte su içerisinde 168 saat bekleme durumunda su girişi olmayacak
1000 saat beklemede elektriksel performans düşümü ve metal korozyonu
olmayacak
1 metreden sert bir zemine 5 kez bırakılınca elektriksel ve fiziksel bozulma
olmayacak
15 PSI basınçta 1 dakika boyunca hava kaçağı olmayacak (Su içerisinde test
edilecek)
75 ohm karakteristik empedans,
Giriş-Çıkış- Tap KES konnektör,
IPX8 (Ingress Protection) standardına uygun
CE Deklerasyon Belgeli,
Insertion Loss (Max.) -dB
Tap Loss (±1,5) -dB
Isolation
Out-Tap Min. -dB
Return Loss In-Out
Return Loss Tap
DIRECTIONAL COUPLER (DC)
Mhz
15-40
40-470
470-1000
15-1000
15-40
40-470
470-1000
15-1000
15-40
40-470
470-1000
8dB
1,9
2,6
3
8
30
25
22
12dB
1,3
1,9
2,4
12
30
25
22
16dB
1,1
1,5
2
16
30
25
22
EN 50083/4 - Çizelge 1 Class B
84 / 126
Ekranlama Faktörü -dB
15-40
40-470
EN 50083/2 - Çizelge 10 Class A
470-1000
1m derinlikte su içerisinde 168 saat bekleme durumunda su girişi olmayacak
1000 saat beklemede elektriksel performans düşümü ve metal korozyonu olmayacak
1 metreden sert bir zemine 5 kez bırakılınca elektriksel ve fiziksel bozulma olmayacak
15 PSI basınçta 1 dakika boyunca hava kaçağı olmayacak (Su içerisinde test edilecek)
Water Sealing Test
Salt Spray (Fog) Test
Drop Test
Air Leakage Test
 75 ohm karakteristik empedans,
 3,5/12 veya PIN (5/8”) konnektör girişi,
 Aluminium alloy housing with weather-resistant powder coating
 IPX8 (Ingress Protection) standardına uygun
 Min. 15 Amper Power Passing,
 CE Deklerasyon Belgeli,
Insertion Loss (Max.) dB
Return Loss ( In-Out min.)
Ekranlama Faktörü
Water Sealing Test
Salt Spray (Fog) Test
Drop Test
Air Leakage Test






LINE POWER INSERTER
Mhz
PI
15-40
0,4
40-470
0,6
470-1000
1,2
15-1000
EN 50083/4 - Çizelge 1 Class B
15-40
40-470
EN 50083/2 - Çizelge 10 Class A
470-1000
1m derinlikte su içerisinde 168 saat bekleme durumunda su girişi
olmayacak
1000 saat beklemede elektriksel performans düşümü ve metal
korozyonu olmayacak
1 metreden sert bir zemine 5 kez bırakılınca elektriksel ve fiziksel
bozulma olmayacak
15 PSI basınçta 1 dakika boyunca hava kaçağı olmayacak (Su
içerisinde test edilecek)
75 ohm karakteristik empedans,
3,5/12 veya PIN (5/8”) konnektör girişi,
Aluminium alloy housing with weather-resistant powder coating
IPX8 (Ingress Protection) standardına uygun
Min. 15 Amper Power Passing,
CE Deklerasyon Belgeli,
GALVANİK İZOLATÖR
Insertion Loss (Max.) dB
Return Loss (In-Out Min.) dB
Ekranlama Faktörü
Galvanik İzolasyon





Mhz
15-1000
15-1000
15-40
40-470
470-1000
GI
0,8
18
EN 50083/2- Çizelge 10 Class
A
2120 V DC / 0,7 mA
230 V AC / 2 mA
75 ohm karakteristik empedans,
Çift yönlü,
En az 1.5 μm NiSn/Nickel kaplı ve gövde ile aynı malzemeden F-Female konnektörlü,
Gold/Silver plated beryllium copper center conductor or Tin Plated phosphorus bronze center conductor
CE Deklerasyon Belgeli,
85 / 126
Insertion Loss (Max.) -dB
Isolation (Decoupling)
(Outputs Min.) -dB
Return Loss (Min.) –dB
Ekranlama Faktörü (Min.) -dB
AHTAPOT TİPİ HARİCİ BÖLÜCÜLER
Mhz
15-1000
15-1000
17
47-1000
15-1000
20
75
1m derinlikte su içerisinde 168 saat bekleme durumunda
su girişi olmayacak
1000 saat beklemede elektriksel performans düşümü ve
metal korozyonu olmayacak
1 metreden sert bir zemine 5 kez bırakılınca elektriksel ve
fiziksel bozulma olmayacak
15 PSI basınçta 1 dakika boyunca hava kaçağı olmayacak
(Su içerisinde test edilecek)
Water Sealing Test
Salt Spray (Fog) Test
Drop Test
Air Leakage Test




2 Way
4
75 ohm karakteristik empedans,
Giriş-Çıkış- KES konnektör,
IPX8 (Ingress Protection) standardına uygun
CE Deklerasyon Belgeli,
86 / 126
RF KONNEKTÖR
TEKNİK ÖZELLİKLERİ
87 / 126
HARİCİ (TRUNK) KONNEKTÖRLER ve ADAPTÖRLER
Türksat Ürün Numarası:
3,5/12
Çalışma Frekansı
Maksimum Geçiş Kaybı
Minimum Ekranlama Faktörü
Minimum Yalıtkanlık Direnci
Transfer Empedansı
Min.Geri Dönüş Kaybı (Return Loss)
Max. Line Power
Gövde Malzeme
Gövde Kaplama malzemesi
İç İletken Malzeme
İç İletken Kaplama malzemesi
O-ring
Water Sealing Test
Salt Spray (Fog) Test
Tension Test
5,8”/Splice
F-Male
5-1000 MHz
0,1 dB
100 dB
29 Gohm
< 0,6 mOhm/con.
30 dB
30 dB
30 dB
10 A
13 A
3A
Pirinç (Brass CuZn39Pb3)
Nikel-Tin / Nitin-6
Tin Bronze / Beryllium Copper/ Pirinç (Brass CuZn39Pb3)
Nikel-Tin / Nitin-6 / Gold
Ethylene Propylene (EPDM)
1 metre su içerisinde 24 saat beklemede
su girişi olmayacak
1000 saat sonunda
her hangi bir korozyon belirtisi olmayacak.
Kablo özelliklerinde belirtilenden daha yüksek bir
çekme gücü uygulandığında konnektör kabloyu bırakmayacak
5-1000 MHz
30-862 MHz
500 Vdc
5-30 MHz
5-1000 MHz
>10 C°
 75 ohm karakteristik empedans,
 IPX8 (Ingress Protection) standardına uygun
 CE Deklerasyon Belgeli,
DAHİLİ KONNEKTÖRLER ve ADAPTÖRLER
F
F-F
IEC
Çalışma Frekansı
5-1000 MHz
Minimum Ekranlama Faktörü
30-862 MHz
100 dB
90 dB
Min.Geri Dönüş Kaybı (Return Loss)
5-1000 MHz
30 dB
30 dB
Maksimum Geçiş Kaybı
5-1000 MHz
0,2 dB
0,3 dB
Transfer Empedansı
5-30 MHz
< 0,15 mOhm/con.
< 0,3 mOhm/con.
Gövde Malzeme
Pirinç (Brass CuZn39Pb3)
Gövde Kaplama malzemesi
Nikel-Tin / Nitin-6
O-ring
Ethylene Propylene (EPDM)
1 metre su içerisinde 24 saat beklemede
Water Sealing Test
su girişi olmayacak
1000 saat sonunda
Salt Spray (Fog) Test
her hangi bir korozyon belirtisi olmayacak.
Kablo özelliklerinde belirtilenden daha yüksek bir
Tension Test
çekme gücü uygulandığında konnektör kabloyu bırakmayacak
 75 ohm karakteristik empedans,
 IPX8 (Ingress Protection) standardına uygun
 Tüm konnektörler sıkıştırmalı olacak (compretion),
 CE Deklerasyon Belgeli,
88 / 126
SONLANDIRMA DİRENÇLERİ
F kilitli
Çalışma Frekansı
Minimum Ekranlama Faktörü
Min.Geri Dönüş Kaybı (Return Loss)
30-862 MHz
5-1000 MHz
Gövde Malzeme
Gövde Kaplama malzemesi
İç İletken Kaplama malzemesi
İç İletken Malzeme
O-ring
 75 ohm karakteristik empedans,
 IPX8 (Ingress Protection) standardına uygun
 CE Deklerasyon Belgeli,
F
5/8”
3,5/12
5-1000 MHz
100
105
110
120
25
25
18
25
Zinc / Bronze/
Pirinç (Brass
(BrassCuZn39Pb3)
CuZn39Pb3)
Nikel
Nikel-Tin / Nitin-6
Tin
Nikel-Tin / Nitin-6
Pirinç (Brass CuZn39Pb3)
Ethylene Propylene (EPDM)
MCX KONNEKTÖR
Minimum Ekranlama Faktörü (RFI)
Maksimum Geçiş Kaybı (1000 MHz'de)
Min.Geri Dönüş Kaybı (Return Loss)
Merkez iletken kaplama malzemesi
Kaplama malzemesi
 75 ohm karakteristik empedans,
 Sıkmalı (Crimp)
 CE Deklerasyon Belgeli,
5-1000 MHz
5-1000 MHz
5-1000 MHz
MCX
100 dB
0,1 dB
30 dB
> .00003” Gold
Nikel
89 / 126
AKÜ-UPS
TEKNİK ÖZELLİKLERİ
90 / 126
KABLO TV SAHA UPS
Giriş Voltajı
Güç
Çıkış Voltajı
380VA
185-260 Vac
48 Vac de 380 VA (Minimum)
63 Vac de 480 VA (Minimum )
48 Vac veya
48 Vac ve 63 Vac
1.75V/Cell
0,90 (Minimum)
8 Amp (Minimum)
36 Vdc (3 akülü)
%82 (Minimum)
Quasi square wave / Pure Sine Wave
50Hz ±3Hz
-20ºC ~ +40ºC
10 saniye(min.)
Online CFR / Line interactive AVR
Akü ve İnverter
Docsis destekleyecek
DC Kesme Voltajı
Giriş Güç Faktörü
Çıkış Akımı
Batarya Giriş Voltajı
Verim (Aküden Çalışma)
Çıkış Dalgaformu
Frekans
Çalışma sıcaklığı
Aşırı Yük %150
Topoloji
Otomatik Manuel Akü testi
Monitoring
 Metal Şase (Maksimum WxDxH = 50x40x30 cm )
 Kısa Devre ve Aşırı Akım Korumalı
 Aküden mi şebekeden mi beslendiği LCD panel ile veya LED ler yardımıyla okunabilmeli
 Çıkış akımı, çıkış gücü, giriş frekansı, çıkış voltajı, akü gerilim yükü, giriş voltajı, şarj akımı ve olay sayısı LCD ekranda
okunabilmeli.
 EN (CENELEC) güvenlik sertifikası olacak
 CE Deklerasyon Belgeli
100W-300W Micro UPS (FTTx/RFOG)
Giriş Voltajı
Çıkış Gücü
Çıkış Voltajı
Batarya Giriş Voltajı
Verim (Aküden Çalışma)
Çıkış Dalgaformu
Frekans
Çalışma sıcaklığı
Transfer time
Topoloji




185-260 Vac
100 - 300 Watt
220 Vac
12 veya 24 Vdc (1 veya 2 akülü)
%80 (Minimum)
Quasi square wave / Sine Wave
50Hz ±3Hz
-20ºC ~ +40ºC
< 5 ms
Online CFR / Line interactive AVR
Maksimum boyut = 25x25x15 cm (Akü bölmesi olmayan UPS ler)
Maksimum boyut = 40x30x15 cm (Akü bölmesi olan UPS ler, En az iki adet 9Ah akü ile)
Kısa Devre ve Aşırı Akım Korumalı
EN (CENELEC) güvenlik sertifikası olacak
91 / 126
19" Rack UPS
2000VA
1000VA
Güç
2000VA
1000VA
Giriş Voltajı
220 Vac
220 Vac
Çıkış Voltajı
220-240 Vac
220-240 Vac
Frekans
50 Hz
50 Hz
Çalışma sıcaklığı
0ºC ~ +40ºC
0ºC ~ +40ºC
Gürültü (1 metre)
< 50 dB
< 45 dB
Çıkış güç faktörü
0,9
0,9
Dalga şekli
Sinüs
Sinüs
Akü tipi
Valf regüleli, dökülmeyen kurşun asitli (VRLA AGM kuru tip )
Voltaj-Güç
12 Volt
Şarj süresi
%90 kapasiteye kadar 3 saat
Akü kabinleri
Tüm aküler özel akü kabininde yer alacaktır.
 Aküler UPS çalışırken kolaylıkla sökülüp takılabilir olmalıdır.
 EN (CENELEC) güvenlik sertifikası olacak
 En az 6 adet priz çıkışı olacak
 19" Rack Tipi olacak
 Kısa Devre ve Aşırı Akım Korumalı
 SNMP destekli uzaktan yönetim modülü içerecektir.
 Maksimum UPS WxDxH = 50x45x10 cm
 CE Deklerasyon Belgeli
12 Volt-55Ah AKÜ
Nominal Voltaj
Kapasite
5 saat için sabit güç deşarj karakteristiği (9.60 V ve 25ºC de)
Çalışma sıcaklık değerleri (Deşarj)
Maksimum Şarj Akımı
Hücre Sayısı
Özboşalım (20ºC de depolama)
 Bakımsız Kuru Tip Akü
 20ºC de Ortalama ömür 10 yıldan fazla olacaktır.
 CE Deklerasyon Belgeli
55Ah
12 Vdc
55 Ah
110 W (Minimum)
–20ºC ~ +50ºC
20 Amper
6 Adet
%10 / 3AY (maksimum)
12 Volt-9Ah/18Ah AKÜ
Nominal Voltaj
Kapasite
1 saat için sabit güç deşarj karakteristiği (9.60V ve 25ºC de)
Çalışma sıcaklık değerleri
Özboşalım (20ºC de depolama)
 Bakımsız Kuru Tip Akü
 20ºC de Ortalama Ömür 5 yıldan fazla olacaktır.
 CE Deklerasyon Belgeli
9 Ah
18 Ah
12 Vdc
9 Ah
18 Ah
65W (Minimum)
130W (Minimum)
0ºC ~ +40ºC
%10 /3AY (maksimum)
12 Volt-100Ah AKÜ
Nominal Voltaj
Kapasite
5 saat için sabit güç deşarj karakteristiği (9.60 V ve 25ºC de)
Çalışma sıcaklık değerleri (Deşarj)
Maksimum Şarj Akımı
Hücre Sayısı
Özboşalım (20ºC de depolama)
 Bakımsız Kuru Tip Akü
 20ºC de Ortalama ömür 10 yıldan fazla olacaktır.
 TSE Belgeli / CE Deklerasyon Belgeli
100Ah
12 Vdc
100 Ah
200 W (Minimum)
–20ºC ~ +50ºC
30 Amper
6 Adet
%10 / 3AY (maksimum)
92 / 126
RF YÜKSELTİCİLER
TEKNİK ÖZELLİKLERİ
93 / 126
BİNA DAĞITIM YÜKSELTİCİLERİ
BA-TİP585
İLERİ YÖN
Frekans Aralığı
Kazanç
Kazanç doğruluğu
Çıkış Seviyesi (CENELEC 42 kanal) CSO: 60 dB ve CTB: 60 dB
Gürültü Figürü (Maksimum kazançta)
Equalizer (eğim)
Kazanç Ayarı
Return Loss
GERİ YÖN
Frekans Aralığı
Kazanç
Kazanç doğruluğu
Noise Figure
GENEL ÖZELLİKLER
Koruma Sınıfı
Konnektor
Test Konnektor
Voltaj Aralığı (Vac)
Ekranlama
Karakterisitik empedans
Power Consumption (Watt)
Ani gerilim koruması
110-1000 MHz
min. 32 dB
±1
min. 104 dBuV
max. 6 dB
0 - min.15 dB
0 - min.18 dB (AGC)
EN 50083/3-Çizelge 1 Class C
5-85 MHz
0 - min. 17 dB
±1
max. 6 dB
min. IP 41
F, female
F, female
26-65 V (Uzaktan) / 220 V (Yerinde)
EN 50083/2 - Çizelge 10 Class A
75 ohm
max. 5 W
6kV-200A
Hem giriş katında hem de hibredler
Equalizer (eğim)
arasında (interstage)
Kazanç Ayarı
Giriş katında
 1 adet TV+Modem (5-1000 MHz), 1 adet TV (85/110-1000 Mhz) ve 2 Test için RF F-female port
 AGC (Otomatik kazanç kontrol sistemi olacak)
 GaAs teknolojisi
 CE Deklerasyon Belgeli
HAT YÜKSELTİCİLERİ
HA-TİP585
İLERİ YÖN
Frekans Aralığı
Kazanç
110-1000 MHz
min. 38 dB
Çıkış Seviyesi (CENELEC 42 kanal)
CSO: 60 dB ve CTB: 60 dB
min.112 dBµV
Gürültü Figürü (Maksimum kazançta)
Equalizer (eğim)
Kazanç Ayarı
Return Loss
max. 7,5 dB
0-min.15 dB
0-min.15 dB
EN 50083/3 - Çizelge 1 Class B
GERİ YÖN
Frekans Aralığı
Kazanç
Noise Figure
ICS (Ingress Control Switches)
5-85 MHz
min. 20 dB
max. 8 dB
0 dB /-6 dB /Off
GENEL ÖZELLİKLER
Koruma Sınıfı
Konnektor
Test Konnektor
Voltaj Aralığı (Vac)
Ekranlama
Frekans doğrusallığı
min. IP 54
3,5/12 Female (Nitin)
F, female
27-65 V (Uzaktan beslemeli)
EN 50083/2 - Çizelge 10 Class A
+/- 0.75 dB
94 / 126
Karakterisitik empedans
75 ohm
Power Consumption (Watt)
max. 25 W (Yönetim modülü hariç)
 Biri aktif olmak üzere en az iki çıkışı (Splitted) olacak ve ayrıca test çıkışı olacak
 GaAs teknolojisi
 Hem giriş katında hem de hibredler arasında (interstage); zayıflatma ve eğim ayarı yapılacaktır.
 Uzaktan kontrol için DOCSIS modem destekleyecek (Modüler)
 CE Deklerasyon Belgeli
95 / 126
PASİF OPTİK ÜRÜN
TEKNİK ÖZELLİKLERİ
96 / 126
OPTİK SPLİTTER (BÖLÜCÜLER)
1:2 Splitter
1:4 Splitter
1:8 Splitter
1280...1620nm
min.50 dB
min.50 dB
3,9 dB
7,2 dB
10,7 dB
Dalga boyları
Directivity
Optik Return Loss
Max. Insertion loss
Max. Uniformity (all wavelengths in
0,7 dB
pass band)
Kasa/Şase tipi
Optik Konnektör
 Eşit bölmeli
 Single Mode Fiber CE Deklerasyon Belgeli
0,8 dB
1 dB
1:16 Splitter
1:32 Splitter
14 dB
18 dB
1,2 dB
2 dB
LGX style chassis / Compact Housing / 19” Rack 1RU
SC/APC veya E2000
AKTİF OPTİK SPLİTTER
İleri Yön Optik
Dalga Boyu
DWDM 1550nm (+/-5nm)
Optik Geçiş Kaybı (+ /- 1dB)
14dB
(1:16)
18dB
Return Loss
(1:32)
>38dB
Geri Yön Optik
Dalga Boyu (Giriş için)
1270nm-1620nm / 1610nm (+/-10nm)
Optik Giriş Gücü
min: -2 dBm
max: 3 dBm
DFB 1610 (+/-10nm)
(CWDM dalga boyları Opsiyonel Olacaktır)
Transmitter Optik Lazer Tipi ve Dalga Boyu
Optik Lazer Çıkış Gücü
3dBm (6dBm Opsiyonel olacaktır)
Lazer Turn-On time
CW (Continous Wave)
Optik İzolasyon(Out Portları Arasında)
min 50 dB
US CER (Uncorrectable Codeword error rate)*
< % 0.01
*6.4 MHz - QAM64 - 4 US kanal, FN out OMI: %10-%15, Splitter inp: +3…0 dBm, RFOG_RRx input= -20dBm,
US Utilization > %80, US Tx Power: 39-50 dBmV, PostFEC için
Geri Yön RF
Frekans Çalışma aralığı
5-85 MHz (204 Mhz destekli)
OMI/Ch %**
min: (ONU_Omi x %70)
Flatness
(+/- 0,5dB)
** 3 dBm optik girişte
Genel Özellikler
Konnektörler
SC/APC
Power Consumption
max 10W
Gerilim
220Vac**/ 27Vac-65Vac (Opsiyonel)
Koruma Sınıfı
Boyut
En az IP 20
Genişlik : 19Inch Uyumlu olacaktır.
Boy
: 1RU veya 2RU
Çalışma Sıcaklığı
EMC
Test Konnektörleri
Karakteristik Empedans
(-20……+55)C
EN 50083-2
F-Female
75ohm
**185Vac-265Vac aralığında stabil çalışması gerekmektedir.
Uygun band geçişlerine sahip entegre WDM veya OADF bulunacaktır.
DS-US aynı port üzerinden iletilecektir.
97 / 126
Dalga boyları
Max. Insertion loss
Max. Insertion loss MUXDEMUX pair
Optik Return Loss
Min. Optical isolation adjacent
channels:
Min Optical isolation nonadjacent channels:
Directivity
Channel spacing [nm]
Passband flatness [dB]
Kasa/Şase tipi
Optik Konnektör
 Single Mode Fiber
 CE Deklerasyon Belgeli
CWDM MUX/DEMUX/FILTER
CWDM MUX-DEMUX
CWDM MUX-DEMUX
8 channel
16 channel
Low Band: 1271- 1451 nm
1471- 1611 nm
High Band: 1471-1611 nm
3,5 dB
4,5 dB
5 dB
6 dB
> 45dB
High/Low Band CWDM
Filter
Low Band: 1271-1451 nm
High Band: 1471-1611 nm
1,5 dB
>50dB
30dB
40dB
-
min.50dB
20nm
≤ 0,5dB
LGX style chassis / Compact Housing
Glas tube/ LGX style
chassis / Compact
Housing
SC/APC veya E2000
98 / 126
Dalga boyları
Max. Insertion loss
Max. Insertion loss MUX-DEMUX pair
Optik Return Loss
Min. Optical isolation adjacent
channels:
Min Optical isolation non-adjacent
channels:
Directivity
Channel spacing [GHz]
DWDM MUX/DEMUX/FILTER
DWDM MUX-DEMUX
DWDM MUX-DEMUX
8 ITU-grid channel
4 ITU-grid channel
ITU 21..39
ITU 21..39
3,0dB
2,3dB
3,9dB
3,0dB
>45dB
>45dB
OADF/OADM
ITU Channels 21 - 39
1,1dB
>45dB
30dB
25dB
40dB
min.50dB
200GHz / 100GHz
Passband [nm]
+/- 0,5nm (200GHz)
veya +/- 0,2nm (100 GHz)
+/- 0,25nm
Passband flatness [dB]
Kasa/Şase tipi
Optik Konnektör
 Single Mode Fiber
 CE Deklerasyon Belgeli
≤ 0,5dB
LGX style chassis / Compact Housing
SC/APC veya E2000
WAVELENGHT-DIVISION-MULTIPLEXER
Dalga boyları
Max. Insertion loss (Tx Port--->Common Port
or Common Port--->Rx Port)
Optik Return Loss
Min. Optical isolation (Common Port--->Tx Port @ 1610nm)
Optik Konnektör
Passband flatness [dB]
Directivity
Kasa/Şase tipi
WDM-1
WDM-2
Tx Port: 1550 +/- min. 20nm
Rx Port: 1610 +/- min 5nm
1 dB
min. 45dB
45dB
SC/APC
≤0,5dB
min.60dB
LGX style chassis
Glas tube
veya Compact
(Mini tube)
Housing
 Single Mode Fiber
 CE Deklerasyon Belgeli
99 / 126
AKTİF OPTİK ÜRÜNLER
TEKNİK ÖZELLİKLERİ
100 / 126
1310nm MULTIWAVELENGHT TRANSMITTER
8 dBm TX
10 dBm TX
12 dBm TX
Optik Özellikler
Çıkış Gücü
8 dBm (min.)
10 dBm (min.)
12 dBm (min.)
Dalga boyu
1290-1350 (min. 4 kanal CWDM)
RIN
<-150 dB/Hz
RF Özellikler
Frekans Aralığı
110-1000 MHz
BC RF giriş seviyesi
Cenelec 42 (Katalog değeri)
RF Giriş Empedansı
75 ohm
Tipik Hat Performansı
CNR** (up to 862MHz)
≥50 dB
CSO** (up to 862MHz)
≥58 dB
CTB** (up to 862MHz)
≥62 dB
Genel Özellikler
RF Konnektor
F-Female
Optik Konnektor
SC/APC veya E2000
Power Consumption (Watt)
≤ 15 W
EMC
EN 50083-2
BC-NC arası RF izolasyon
> 45dB
 Hem BC hem de NC girişi için ayrı portlar olacaktır. Giriş test noktası olacaktır.
 DFB lazer
 ** 30km link, Cenelec 42 kanal planı, Tek dalga boyu, Optik receiver giriş gücü 0 dBm ve Noise bandwidth 5MHz. ile
 SNMP destekleyecek
 CE Deklerasyon Belgeli
C-BAND DWDM TRANSMITTER
C-Band ST TX
Optik Özellikler
C-Band EM TX
ITU Grid Channel
C21 … C39 aralığında en az 8 dalga boyu
min. 8 dBm
<-150 dB/Hz
<-155 dB/Hz
Dalga boyu
Çıkış Gücü
RIN
RF Özellikler
Frekans Aralığı
BC RF giriş seviyesi
RF Giriş Empedansı
CNR** (up to 862MHz)
CSO** (up to 862MHz)
CTB** (up to 862MHz)
RF Konnektor
Optik Konnektor
Power Consumption (Watt)
EMC
110-1000 MHz
Cenelec 42 (Katalog değeri)
75 ohm
Tipik Hat Performansı
≥50 dB
≥58 dB
≥62 dB
Genel Özellikler
≥52 dB
≥65 dB
≥65 dB
F
SC/APC veya E2000
≤ 20 W
≤ 45 W
EN 50083-2
Electro Absobtion / Direct
Modulasyon
Externally Modulated
Modulated
Total SBS Suppression (1, 2, 4, 8 Wavelenghts)
≥ 17 dBm
BC-NC arası RF izolasyon
> 50dB
 Hem BC hem de NC girişi için ayrı portlar olacaktır. Narrowcast projelerinde sadece TV girişi için kullanılacak
Broadcast Transmitterlerda BC girişi için tek port olması yeterli olacaktır.
 DFB lazer
 Giriş test noktası olacaktır.
 ** 30km link, Cenelec 42 kanal planı, Tek dalga boyu, Optik receiver giriş gücü 0 dBm ve Noise bandwidth 5MHz. ile
 SNMP destekleyecek
 CE Deklerasyon Belgeli
101 / 126
NARROWCAST TRANSMITTER
NC TX
Optik Özellikler
ITU Grid Channel
C21 … C39 aralığında en az 8 dalga boyu
min. 10 dBm
<-150 dB/Hz
Dalga boyu
Çıkış Gücü
RIN
RF Özellikler
Frekans Aralığı
NC RF giriş seviyesi
RF Giriş Empedansı
110-1000 MHz
Cenelec 42 (Katalog değeri)
75 ohm
Tipik Hat Performansı
MER**
BER (pre-FEC)**
38 dB
≤ 10e-8
Genel Özellikler
RF Konnektor
Optik Konnektor
Power Consumption (Watt)
EMC
 DFB lazer
 Giriş test noktası olacaktır.
 **32 QAM256 kanalı ile, optik receiver giriş seviyesi -5dBm'de, 50km link
 SNMP destekleyecek
 CE Deklerasyon Belgeli
F
SC/APC veya E2000
≤ 20 W
EN 50083-2
OPTİK YÜKSELTİCİLER
16 dB EDFA
20 dB EDFA
13 dB GFEDFA 16 dB GFEDFA
Optik Özellikler
1x13 dBm
1x16 dBm
4x20 dBm
1x13 dBm
1x16 dBm
ITU Grid Channel 21 … 39
(1545nm -1561 nm)
max. 0 dBm ile min. +10dBm aralığında
≤6dB (at 0 dBm input)
±0,5dB
> 40 dB
Genel Özellikler
SC/APC veya E2000
EN 50083-2
15
15
30
15
15
13 dB EDFA
Çıkış Gücü dBm (±1dB)
Dalga boyu
Giriş Gücü
Noise Figure
Flatness (1545nm -1560 nm)
Optical return loss
Optik Konnektor
EMC
Power Consumption (Watt)
 DFB lazer
 SNMP destekleyecek
 Subrack üzerine takılabilir şekilde modüler olacak
 Harici uygulamalarda kullanılan tipler için IP 54 koruma sınıfı olacak
 CE Deklerasyon Belgeli
102 / 126
GERİ YÖN OPTİK ALICILARI
Dalga boyu
Giriş Gücü Aralığı (min)
Optical Return loss
Detector responsivity
RX
Optik Özellikler
1290 ... 1600 nm
-16 dBm ile -3 dBm
RFOG RX
1270.....1610 nm
- 25 .... - 15 dBm
≥ 30 dB
≥ 0.8 A/W
RF Özellikler
Çıkış sayısı (min)
Çıkış gücü
RF Band (min)
RF Frequency Response (5-85 MHz)
Isolation (All RF port)
RF Return Loss
Noise Equivalent Power (pA/sqrt(Hz))
2
min. 90 dBuV
+/- 0.75 dB
<8
2 (1:1 Combine özelliği)
min. 80 dBµV
5-85 MHz
± 1 dB
≥ 50 dB
≥ 16 dB
≤ 1.5
Genel Özellikler
Optik Konnektor
RF Konnektor
Power Consumption (Watt)
EMC
 SNMP destekleyecek
 CE Deklerasyon Belgeli
 Aktif optik Taşıyıcı ünite içerisine konulabilir yapıda olacaktır.
SC/APC veya E2000
F-female
< 15 W
≤ 10 W
EN 50083-2
103 / 126
OPTİK ALICILAR (FİBER NODE)
1x1FN
2x2FN
FTTB Node
RFOG FN
min.110 dBµV
(1 Out)
min.96 dBµV
Optik Özellikler
Maksimum Çıkış Seviyesi
(CENELEC 42 kanal, CSO: 60 dB ve
CTB:60 dB için)
min.112 dBµV
(Splitted 2 Out)
İleriyön Dalga boyu
2 x min.112 dBµV
(Active 2 Out)
min.
1550..1560nm
min. 1290 ... 1600 nm
Optik giriş seviyesi aralığı
min. (-6…+1) dBm
Equivalent noise current density,
input
Photo-diode sensitivity
(resposivity)
min. (-6 … 0) dBm
min. (-5 … 0) dBm
<7pA/sqrt(Hz)
< 5.5 pA/√Hz
0,85(A/W) 1310nm ve
0,95(A/W) 1550nm
> 0,8 A/W
İLERİ YÖN
Frekans Aralığı
110-1000 MHz
Equalizer (eğim)
0-min.15 dB
-
-
Kazanç Ayarı
0-min.15 dB
-
-
Return Loss
>18 dB - 1.5 dB/oct
EN 50083/3- Çizelge 1 Class C
GERİ YÖN
Frekans Aralığı
5-85 MHz
Kazanç Ayarı
0-min.15 dB
-
Geri yön transmitter
DFB lazer
Dalga Boyları
Optik çıkış seviye
-
CWDM (min. 16 dalga boyu)
DFB(1610nm)
+3 dBm veya +6 dBm
+3 dBm
+3 dBm
0 dB /-6 dB /Off
-
-
ICS (Ingress Control Switches)
Genel Özellikler
Koruma Sınıfı
IP 54
IP 41
IP 41
RF Konnektor
3,5/12 female (Nitin)
F-female
F-female
F, female
F-female
-
220 Vac
220 Vac
Test Konnektor
Optik Konnektor
SC/APC
Voltaj Aralığı (Vac)
35-60 Vac
Karakterisitik empedans
75 ohm
Frekans doğrusallığı
Power Consumption (Watt)
TX turn on/off time
AGC (Automatic Gain Control)
+/- 1 dB
+/- 1,5 dB
max. 30 W
(Full)
max. 60 W
(Full)
max. 15 W
(Full)
max. 8 W
(Full)
-
-
-
< 1.5 μs
Evet
Evet
Evet
-
 ITU G.694.2 en az 16 CWDM dalga boyu desteklenecek
 Uzaktan kontrol için DOCSIS modem destekleyecek
 GaAs Teknolojisi
 Hem giriş katında hem de hybridler arasında (interstage); zayıflatma ve
eğim ayarı yapılacaktır.
 Docsis 3.0 Uyumlu
 CE Deklerasyon Belgeli
 Docsis 3.0 Uyumlu
 CE Deklerasyon Belgeli
104 / 126
1610nm OBI Free RFOG Node
Optik Özellikler
İleri Yön
Maksimum Çıkış Seviyesi
(CENELEC 42 kanal, CSO: 60 dB ve CTB:60 dB için)
İleri Yön Dalga Boyu
Optik Giriş Seviyesi
Equivalent Noise Current
Photo-diode Sensitivity
Min. 96 dBuV
1550nm (+/-5)
0….-5 dBm
<5,5pA/rt(Hz)
>0,8A/W
Geri Yön
Geri Yön Transmitter
Optik Çıkış seviye
Dalga boyu
DFB lazer
3dBm
1610nm (+/-10)
OBI free olacak şekilde ayarlanacak en az 16 adet dalga boyu
Dalga Boyları*
olacaktır.
US CER (Uncorrectable Codeword error rate)**
< % 0.1
*Dalga boyu node üzerinden manuel/otomatik olarak ayarlanabilecektir.
*Dalga Boyları, kesinlikle hiçbir dış ortam kaynaklı etken yüzünden ayarlandığı seviyeden değişmeyecektir.
**6.4 MHz - QAM64 - 4 US kanal, FNRx=71-82 dBuV, RFOG_RRx= -20 dBm input, US Utilization > %80, US Tx Power: 39-50
dBmV, PostFEC için
RF İLERİ YÖN
Frekans Aralığı
Eğimm
Kazanç Ayarı
Return Loss
110-1000 MHz
0-15dB min
0-15dB min
EN 50083/3 Çizelge 1 Class C
RF Geri Yön
Ferkans Aralığı
OMI Seviyesi
5-85mHz
70-75dBuV Node İnput ile %15 per chan.
Genel Özellikler
Koruma Sınıfı
Rf Konnektör
Optik Konnektör
Voltaj Aralığı
Karakteristik Empedans
Frekans Doğrusallığı
Power Consumption
Tx Turn On/Off time
Çalışma Sıcaklığı***
***Ortam sıcaklığı değişimi ile kesinlikle dalga boylarında oynama olmayacak.
Docsis 3.0 Uyumlu
CE Deklerasyon Belgeli
IP41
F-Female
SC/APC
220Vac
75 Ohm
(+/-) 1,5db
8W
< 1,5uS
(-20….+60)C
105 / 126
CWDM OBI Free Node
Optik Özellikler
İleri Yön
Maksimum Çıkış Seviyesi
(CENELEC 42 kanal, CSO: 60 dB ve CTB:60 dB için)
İleri Yön Dalga Boyu
Optik Giriş Seviyesi
Equivalent Noise Current
Photo-diode Sensitivity
Min. 96 dBuv
1550 nm (+/-5)
0….-5 dBm
<5,5pA/rt(Hz)
>0,8A/W
Geri Yön
Geri Yön Transmitter
Optik Çıkış seviye
Dalga boyu
DFB lazer
3dBm
CWDM
OBI free olacak şekilde ayarlanacak en az 16 adet dalga boyu
olacaktır.
Dalga Boyları*
(Tüm dalga boyları 1470 - 1620 nm arasında olacaktır.)
(PON dalgaboyları ve 1550 nm hariç)
US CER (Uncorrectable Codeword error rate)**
< % 0.1
*Dalga boyu node üzerinden manuel/otomatik olarak ayarlanabilecektir.
**6.4 MHz - QAM64 - 4 US kanal, FNRx=71-82 dBuV, RFOG_RRx= -20 dBm input, US Utilization > %80, US Tx Power: 39-50 dBmV,
PostFEC için
RF İLERİ YÖN
Frekans Aralığı
110-1000 MHz
Eğimm
0-15dB min
Kazanç Ayarı
0-15dB min
Return Loss
EN 50083/3 Çizelge 1 Class C
RF Geri Yön
Ferkans Aralığı
5-85 MHz
OMI Seviyesi
70-75dBuV Node İnput ile %14 per chan.
Geri Yön Kazanç
15dB
Genel Özellikler
Koruma Sınıfı
IP41
Rf Konnektör
F-Female
Optik Konnektör
SC/APC
Voltaj Aralığı
220Vac
Karakteristik Empedans
75 Ohm
Frekans Doğrusallığı
(+/-) 1,5dB
Power Consumption
15W
Tx Turn On/Off time
1,5uS
Çalışma Sıcaklığı***
(-40….+65)C
***Ortam sıcaklığı değişimi ve dış etkenler yüzünden kesinlikle OBI oluşmayacaktır.
Docsis 3.0 Uyumlu
CE Deklerasyon Belgeli
106 / 126
DAĞITIM DOLAPLARI
TEKNİK ÖZELLİKLERİ
107 / 126
GALVANİZLİ SAC KABİNETLER
108 / 126
BİNA DAĞITIM KUTULARI
Büyük BDK Dolabı
Küçük BDK Dolabı
Ürün Ölçüleri
Y 500 x G 400 x D 200 mm
Y 400 x G 300 x D 200 mm
Kapak Sacı
En az 0,60 mm kalınlığında DKP A1 Kalite Sac
En az 1 mm kalınlığında Galvanizli
En az 1 mm kalınlığında Galvanizli
Arka Sacı
Sac
Sac
RAL 7035 renginde olacak ve polyester tipi toz boyalar kullanılacaktır.
Renk
Kaplama 65 ± 15 mikron kalınlığında olacaktır
 Kapak, menteşeli ya da iki noktadan asılabilir yapıda olacaktır.
 Arka sac delikli olacak ve duvara monte edilecek yapıda olacaktır.
 Dolap Asma kilit aparatlı ve Mesan 055 olacaktır.
 Montaj için gerekli tüm aparatlar içinde yer alacaktır.
109 / 126
IP 55 FİBER NODE/UPS SAHA DOLABI
 Ürün ölçüleri, H 160 x W 75 x D 60 cm olacaktır.
 Çift cidarlı olup; dış panelleri: 2 mm, iç panelleri: 1,2mm kalınlığında TS 822 Galvaniz kullanılacaktır.
 Dolapların iki cidarı arasında minimum 25mm hava boşluğu olacak ve alttan giren taze ve serin havanın
arada ısınan sıcak havayı iterek üst boşluktan atılmasını sağlayan bir yapı bulunacaktır.
 Dolaplarının tavan sacı ile çatı sacı arasındaki boşluk, havanın dolaşmasına müsaade edecek şekilde
olacak ve çatının siperlerinde hava sirkülasyonuna izin veren panjurlar yer alacaktır.
 Tüm galvaniz parçalar kromatlama işleminden sonra dışarıdan görünen yüzeylerin tamamı Ral-7035
Polyester/antigrafiti esaslı pürüzsüz, renk dağılımı üniform elektrostatik toz boya ile boyanmış olacaktır.
Kaplama 65 ± 15 mikron kalınlığında olmalıdır.
 Boyanacak yüzeylerdeki, pas ve yağlar temizlenmeli, sivri kenarlar taşlanmalı ve pürüzlü yerler zımpara
ile düzeltilmelidir.
 Dolaplar IEC 60529 standartına göre IP55 sızdırmazlık şartlarını sağlayacak ve mekanik darbelere karşı
korunma sınıfı IK10 olacaktır.
 Dolapları 4 noktadan paslanmaz çelik bağlantı elemanları ile Baza ya bağlanacaktır.
 Dolapların imalatında kullanılacak malzemeler RoHS* standartına uygun olacaktır.
 Kapılarda da çift cidar uygulaması olacaktır.
 Dolapların kapılarında, gövdeyi en az 3 noktadan kavrayacak, paslanmaz çelik veya ZAMAK malzemeden
üretilmiş kilit mekanizması bulunacaktır.
 Galvanizleme işlemi ve galvanize edilmiş yüzeyler üzerindeki deneyler, TS 822 standartlarına uygun
olarak yapılacaktır.
 Boyanamayan ve soğuk galvaniz yapılamayan küçük parçalar elektro galvaniz kaplama yapılacaktır.
Elektro galvaniz kalınlığı 12 mikrondan az olmayacak ve galvanizlemeden sonra uygun bir metotla
pasifleme işlemi yapılacaktır.
 Dolap içinde Alüminyum Profil Gövdeli 6'lı Priz Modülü yer alacak.
 Dolap içinde 1 adet 600/800MM Sabit Raf yer alacaktır.
 Dolap içinde 1 adet 600/800MM Hareketli Raf yer alacaktır.
 Elektrik dağıtım şirketlerinin farklı uygulamaları sebebiyle dolap içinde 3x25A veya 1x16A Otomatik
Sigorta yer alacaktır.
 Elektrik dağıtım şirketlerinin farklı uygulamaları sebebiyle dolap içinde Kaçak Akım Rolesi 3x25 30mA
veya 1x25 30mA yer alacaktır.
 Dolap içinde Parafudur 250VAC 40kA 10/350ms yer alacaktır.
 Kilit mekanizması için 9 mm ispanyolet demiri kullanılacaktır.
 Kilit: MESAN 408 Yüksek Güvenlikli Silindir Barel kullanılacaktır.
Opsiyonel olarak aşağıdaki aksesurlar takılabilir olacaktır.
 Eşanjör Modülü 60 W/K Eşanjör Modülü 80 W/K
 Eşanjör Modülü 110 W/K
 3’lü Fan Modülü Dijital Termostatlı Emergency Free Cooling
 F5 Filitre Modülü Emergency Free Cooling
 Aşağıda özellikleri verilen UPS Dolabı Akü Koruma Kapağı
 Kasa Ölçüsü
: G687 x Y330 mm
 Kapak Ölçüsü
: G607 x Y258 mm
 2 mm Galvaniz Sac'dan imal edilecektir.
 Kilit : MESAN 056 Yüksek Güvenlikli Silindir Barel ( Kapak üzerinde 2 adet Bulunacak)
110 / 126
IP 55 P-OTD (PASİF OPTİK TERMİNASYON DOLABI)

IP55 Fiber Node / UPS saha dolabının teknik özelliklerini sağlayacaktır. İçerisinde enerji ünitesi ve
raflar olmayıp , 4 adet 19’’ cihaz montaj dikmesi olacaktır.
YÜKSELTİCİ SAHA DOLABI (TİP B)
Yükseltici Dolabı
Ürün Ölçüleri
Y 92 x G 40 x D 27
Yan, Şapka, Arka ve Kapak Sacı
1,20 mm kalınlığında Galvanizli Sac
RAL 7035 renginde olacak ve polyester tipi toz boyalar
Renk
kullanılacaktır. Kaplama 65 ± 15 mikron kalınlığında olacaktır
 Dolap Asma kilit aparatlı ve Mesan 001 olacaktır.
 Yanlarda havalandırma boşlukları olacaktır.
 Malzeme bağlantıları için arkada en az 1,20mm kalınlığında galvanizli sac plaka olacaktır. Sac plaka
dolabın arkasına vidalamaya uygun şekilde yeterince mesafeli sabitlenmelidir.
 Dolap altında vidalanarak tutturulabilen ve kablo deliklerinin bulunduğu kapama sacı olacaktır.
 Montaj için gerekli tüm aparatlar içinde yer alacaktır.
111 / 126
PASİF SAHA DOLABI (TİP C)
Yükseltici Dolabı
Ürün Ölçüleri
Y 65.5 x G 27 x D 25
Yan, Şapka, Arka ve Kapak Sacı
1,20 mm kalınlığında Galvanizli Sac
RAL 7035 renginde olacak ve polyester tipi toz boyalar
Renk
kullanılacaktır. Kaplama 65 ± 15 mikron kalınlığında olacaktır
 Dolap Asma kilit aparatlı ve Mesan 001 olacaktır.
 Yanlarda havalandırma boşlukları olacaktır.
 Montaj için gerekli tüm aparatlar içinde yer alacaktır.
112 / 126
IP55 HARİCİ TİP
ALÜMİNYUM KABİNETLER
113 / 126
GENEL ÖZELLİKLER
Ebatlar
TİP 80: W=800, H=1400mm, D=800mm
TİP 125: W=1250, H=1400mm, D=800mm
TİP 190: W=1900, H=1520mm, D=900mm
Kapılar ve Kilit
180º açılabilir kapılar, üç noktadan kilitleyen zamak veya paslanmaz
çelikten mamul kilit mekanizması.
Koruma sınıfı
Kabinet IEC 60529 standartına göre IP55 sızdırmazlık şartlarını
sağlayacak ve mekanik darbelere karşı korunma sınıfı IK10 olacaktır.
Kablo girişleri
Tabanda yer alacak
Konstrüksiyon
Temel malzemeler ve standartlar
Boya ve yüzey işlem süreçleri
Topraklama
Mapalar
Menteşeler
Baza
İç yapısı
19” montaj dikmesi
Ön Kapı Sayısı
 Modüler yapıda,
 Çekme profil yapısında,
 Bağlantı elemanları profilde bulunan kanal içine tutturulacak,
 Kapılar, yan-arka paneller ve kabinet tavanı çift cidarlı olacak,
 Uygun yerlerde havalandırma panjuru olacak,
 Kabin üzerinde kullanılan tüm bağlama elemanları; vidalar, pullar,
somunlar, perçinler, somun perçinler v.s. paslanmaz çelikten
olacaktır.
 Ana taşıyıcı profiller, kapılar, paneller ve kabinet tavanı
alüminyumdan üretilecek,
 Kabinet içi bileşenler paslanmaz çelikten üretilecek,
 Kullanılan tüm malzemeler alev geciktirici özelliğe sahip olacak,
 Çift cidarlı dış panellerde: 3mm, iç panellerde: 1,5mm kalınlığında
AlMg3 malzeme kullanılacaktır.
 Kabinetin iki cidarı arasında minimum 20mm hava boşluğu olup
alttan giren taze ve serin havanın arada ısınan sıcak havayı iterek üst
boşluktan atılmasını sağlayan bir yapı bulunacaktır.
 Kabinetin tavan sacı ile çatı sacı arasındaki boşluk, havanın
dolaşmasına müsaade edecek şekilde olacak ve çatının siperlerinde
hava sirkülasyonuna izin veren panjurlar yer alacaktır.
 Kabinetin dış panelleri değiştirilebilir yapıda olacaktır.
 Alüminyum levhalar özel yüzey işlem sürecinden geçtikten sonra
RAL 7032 boya ile boyanacak.
 Boya kalınlığı: 60-80 mikron olacak.
 Tüm alüminyum parçalar aludin kaplamalı (kromatlama), dışarıdan
görünen yüzeylerin tamamı Ral-7035 (Ral-7032 yerine)
Polyester/antigrafiti esaslı pürüzsüz, renk dağılımı üniform
elektrostatik toz boya ile boyanmış olacaktır.
Her kapının iç kısmının alt tarafında menteşeye yakın boyasız noktaya
topraklama için M6 somun konulacak.
Ayrıca kabinet içindeki her bölümde 6’lı veya 8’li topraklama barası
bulunacak.
Taşıma için şapkanın altında dört adet mapa monte edilecek.
Anti-vandal özellikli alüminyum menteşe, kabinet kapısının profili
içerisinde boydan boya kanal içine sabitlenerek kapının bir uzantısını
oluşturacak.
2 mm paslanmaz sacdan imal edilip, W=100 mm olacak.
Standartta (çizimde) belirtilen iç yapısı montaj dikmesi/raf eklenerek
veya çıkarılarak değiştirilebilecektir.
TİP 80: 4 adet 19" cihaz montaj dikmesi - 28U
TİP 125: 4 adet 19" cihaz montaj dikmesi - 28U
TİP 190: 8 adet 19" cihaz montaj dikmesi - 30U
TİP 80: 1 kapılı
114 / 126
TİP 125: 2 kapılı
TİP 190: 3 kapılı
Soğutma ünitesi
İsteğe göre aşağıdaki çözümler uygulanabilecektir.
 Filtreli fan
 Isı eşanjörü
 Klima
Beton Şablonu
Beton kaidenin üstüne kılavuz olarak kullanılmak üzere ölçülere uygun
beton şablonu olacaktır.
 Kabin içinde Alüminyum Profil Gövdeli 6'lı Priz Modülü yer alacak.
 Kabin içinde 1 adet 600/800MM Sabit Raf yer alacaktır.
 Kabin içinde 1 adet 600/800MM Hareketli Raf yer alacaktır.
 Kabin içinde 3x63 A Otomatik Sigorta yer alacaktır.
 Kabin içinde Kaçak Akım Rolesi 3x63 30mA yer alacaktır.
 Kabin içinde Parafudur 250VAC 40kA 10/350ms yer alacaktır.
 Kabin içinde 1 adet 32Amp Erkek Jeneratör Prizi yer alacaktır.
 Kabin içinde 1 adet Jeneratör için Pako Şalter 1-0-2 Monofaze yer alacaktır.
Aüminyum profil
Alüminyum levha
Paslanmaz sac levha
Boya
Kilit
Fan
Kullanılan bağlantı elemanları
Yüzey işlem prosesi
MALZEME ÖZELLİKLERİ
TS EN 755-9
EN AW5754 H22, TS EN 485 – 1, TS EN 485-2, TS EN 485-4
DIN 17455
ISO 9001, ISO2178,ISO6272,ISO8130-5, TS EN 8130-3 RAL 7035
DIN 1743, DIN 5371
CE (2004 / 108 / EC EMC / 2006 / 95 / EC LVD), RoHS
DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933
DIN50939 standardına göre kromatlama
ÜRÜN TEST SERTİFİKASYONLARI
Güneş ışınları radyasyon standardına uyumluluk
ETS 300 019 1-4
Elektromanyetik radyasyon etkileşim standardına
EN 300 386-2
uyumluluk (EMC / ERM)
Nakledilme
ETS 300 019 -1 - 2 CLASS 2.3
Depolama
ETS 300 019 - 1 - 1 CLASS 1.2
Dış darbelere karşı koruma
IEC 62208-9.6
IP55 Toz ve sızdırmazlık
EN60529
115 / 126
116 / 126
117 / 126
ÇEŞİTLİ MALZEMELER
118 / 126
PVC KABLO KANALLARI
119 / 126
1) Genel Özellikler
a) Kullanılacak PVC kablo kanalları en az 40x25 mm 25x25 mm 60x40 mm 80x40 mm ve ölçülerinde tam
raduslu, tam kapaklı ve tum montaj tamamlama aksasurlarına sahıp olmalıdır. (iç köşe ve dış köşe menteşeli
hareketli olmalıdır)
b) Kablo kanalları TSE 50085-2-1, ISO 9001–2008 ve VDE belgesine sahip olmalı ve belgelendirilmelidir.
c) Kullanılacak kablo kanalları boyanabilir ve güneş 500 W lık UV ışığına dayanıklı olmalıdır. Bu test
belgelendirilmiş olmalıdır.
d) Kablo Kanalları M1 sınıfı hammaddeden üretilmiş olup alev iletmeme özelliğine ve (M1 UL94 V-0) test
raporuna sahip olmalıdır.
e) Kablo kanalları TSE’den belgeli IP 40 koruma sınıfında olmalıdır.
f) Kullanılacak kablo kanalları kurşunsuz hammaddeden üretilmiş olmalı ve (VDE den ROHS) özelliğine sahip
olmalıdır ve belgelendirilmelidir.
0
0
g) VDE den çalışma ortam sıcaklığı (- 25 C +60 C) raporu olmalıdır.
h) Kullanılacak kablo kanalları hidrolik ve sülfirik asitlere maruz kaldığında yüzeyinde ve renginde herhangi bir
değişiklik olmamalıdır.
i) PVC kablo kanallarının yatay ve dikey montaj delikleri olmalıdır. Kanallar 25 cm aralıklarla çapraz şekilde vida
ve pul kullanılarak monte edilecektir.
2) Hammadde Özellikleri
Malzeme Özellikleri
İstenen Değer
25x25
Renk
Yığın Yoğunluğu
40x25
Test Yöntemi
RAL 9010 ve 9016 Aralığında beyaz
Min. 0,52 g/cm³
TS 448 EN ISO 60
109.0 - 122.0 cm³/g.
TS EN ISO 1628-2
66 - 70
TS EN ISO 1628-2
Tane Boyut Dağılımı:
> 0.250 mm.
> 0.063 mm.
Max. 8 % wt
Max. 90 % wt
ISO 13320
Uçucu Madde
Max. 0.5 % wt
TS EN ISO 1269
Max. 60 adet / 9 dm²
TS EN ISO 1265
Viskozite Sayısı (Siklohekzanon 25°C)
K Sayısı (Siklohekzanon 25°C)
Kirlilik
19” RACK SİSTEM KABİNİ 42 U (80X80 CM) (4 lü fan ve 2x18 li grup priz (otomat) dahil )
Kabinin arka tarafında sağda ve solda iki adet metal kablo kanalı bulunacaktır. Ön tarafta sağda ve solda olmak üzere
boydan boya kablo organizer yer alacaktır. Kabinin arka tarafında sağda 2x9, solda 2x9 grup priz yer alacaktır ve her
Grup priz için 16A sigorta bulunacaktır. Kabin alttan ve üstten kablo girişine uygun olacaktır. Kabin tekerlekli yapıda
olacaktır.
120 / 126
MALZEME LİSTESİ
VE
ÜRÜN KODLARI
121 / 126
CİDARLI HDPE BORULAR VE
AKSESURLARI
HDPE BORULAR VE AKSESURLARI
EK ODALARI VE KAPAKLARI
FİBER OPTİK KABLOLAR
(FOY: Yeraltı, FOH: Havai)
FİBER OPTİK ARA BAĞLANTI
KABLOSU VE TERMİNASYON
SETLERİ
FİBER OPTİK EK KUTULARI
YERALTI KOAKSİYEL KABLOLAR
MALZEME
50 mm HDPE Boru
75 mm HDPE Boru
Birleştirme Manşonu
2x40 HDPE Boru
2X40 Tıkama Kepi
2X40 Birleştirme Manşonu
16 ATU Boru
40X32X32 3'lü Hdpe Göz Çoklayıcı Boru
63 mm PE Boru
TİP 200A EK Odası
TİP 200B EK Odası
TİP 100A EK Odası
TİP 100B EK Odası
Kompozit EK Odası Kapağı
Kompozit Kare EK Odası
Çelik Spiral Boru Ø26mm.
Ek Odası Kapağı (Sfero Döküm 60x80cm.)
Ek Odası Kapak Çerçevesi (Sfero Döküm 60x80cm.)
Tip 300A Ek Odası
Kompozit Ek Odası Kapağı – Metal Levhalı
4 FOY Fiber Optik Kablo
12 FOY Fiber Optik Kablo
24 FOY Fiber Optik Kablo
96 FOY Fiber Optik Kablo
144 FOY Fiber Optik Kablo
216 FOY Fiber Optik Kablo
12 FOH Fiber Optik Kablo
24 FOH Fiber Optik Kablo
96 FOH Fiber Optik Kablo
216 FOH Fiber Optik Kablo
Patchcord SC/APC to SC/APC, SM, Simplex, L= 1m
Patchcord SC/APC to SC/APC, SM, Simplex, L= 5m
Patchcord SC/APC to SC/APC, SM, Simplex, L= 10m
Patchcord SC/APC to E2000, Simplex, L= 1m
Patchcord SC/APC to E2000, Simplex, L= 5m
Patchcord SC/APC to E2000, Simplex, L= 10m
Pigtail SC/APC, SM, Simplex, L= 3m
12FO 19" Terminasyon Seti (Full Dolu)
24FO 19" Terminasyon Seti (Full Dolu)
48FO 19" Terminasyon Seti (Full Dolu)
96FO 19" Terminasyon Seti (Full Dolu)
ZIRHLI PATCHCORD
ZIRHLI PIGTAIL
Patchcord SC/APC TO SC/APC,SM,Simplex, L=1M
Patchcord SC/APC TO E2000,Simplex, L=1M
Pigtail SC/APC, SM, Simplex , L=1M
SC/APC SM Simplex Adapter
19” 1U Patch Panel (BOŞ)
Fiber Optik Kablo Ek Kutusu (1Kaset / 12Port)
Fiber Optik Kablo Ek Kutusu (2Kaset / 24Port)
Fiber Optik Kablo Ek Kutusu (4Kaset / 48Port)
Fiber Optik Kablo Ek Kutusu (8Kaset / 96Port)
Fiber Optik Kablo Ek Kutusu (18Kaset / 216Port)
12 Port EK Kaseti
Dahili Fiber Optik Kablo Ek Kutusu (1Kaset / 12Port)
4 Port Dahili FO Ek Kutusu(Full Dolu)
Yeraltı Koaksiyel Kablo - 2,2 mm Bakır
Türksat Kodu
TKS-ALT-01
TKS-ALT-02
TKS-ALT-03
TKS-ALT-04
TKS-ALT-05
TKS-ALT-06
TKS-ALT-07
TKS-ALT-17
TKS-ALT-18
TKS-ALT-08
TKS-ALT-09
TKS-ALT-10
TKS-ALT-11
TKS-ALT-12
TKS-ALT-13
TKS-ALT-14
TKS-ALT-15
TKS-ALT-16
TKS-ALT-19
TKS-ALT-20
TKS-FOM-35
TKS-FOM-01
TKS-FOM-02
TKS-FOM-03
TKS-FOM-29
TKS-FOM-04
TKS-FOM-05
TKS-FOM-06
TKS-FOM-07
TKS-FOM-08
TKS-FOM-09
TKS-FOM-10
TKS-FOM-11
TKS-FOM-12
TKS-FOM-13
TKS-FOM-14
TKS-FOM-15
TKS-FOM-16
TKS-FOM-17
TKS-FOM-18
TKS-FOM-19
TKS-FOM-27
TKS-FOM-28
TKS-FOM-30
TKS-FOM-31
TKS-FOM-32
TKS-FOM-33
TKS-FOM-34
TKS-FOM-20
TKS-FOM-21
TKS-FOM-22
TKS-FOM-23
TKS-FOM-24
TKS-FOM-25
TKS-FOM-26
TKS-FOM-35
TKS-KAB-01
122 / 126
HAVAİ KOAKSİYEL KABLOLAR
DAHİLİ KOAKSİYEL KABLOLAR
DAHİLİ RF BÖLÜCÜLER
HARİCİ RF BÖLÜCÜLER
DAHİLİ RF DAĞITICILAR
HARİCİ RF DAĞITICILAR
AHTAPOT TİPİ DAĞITICI / BÖLÜCÜ
DC & PI & GI
HARİCİ (TRUNK) KONNEKTÖRLER
DAHİLİ KONNEKTÖRLER
SONLANDIRMA KONNEKTÖRLERİ
UPS & AKÜ
Yeraltı Koaksiyel Kablo - 3,3 mm Bakır
Yeraltı Koaksiyel Kablo - 3,15 mm Aluminyum
Yeraltı Koaksiyel Kablo - 4,22 mm Aluminyum
Fider Kablo – RG11 Bakır
Fider Kablo – TRS 2,2 Bakır
JUMPER (0 - 5m) (5/8 or 3,5/12-RG-5/8 or 3,5/12)
Havai Koaksiyel Kablo - 2,2 mm Bakır
Havai Koaksiyel Kablo - 3,3 mm Bakır
Havai Koaksiyel Kablo - 3,15 mm Aluminyum
Havai Koaksiyel Kablo - 4,22 mm Aluminyum
Havai Fider Kablo – RG11 Bakır
Havai Fider Kablo – TRS 2,2 Bakır
Dahili Koaksiyel Kablo – RG11 Bakır
Dahili Koaksiyel Kablo – RG6 CCS
CMTS Kablosu
2 yollu dahili bölücü (splitter)
3 yollu dahili bölücü (splitter)
4 yollu dahili bölücü (splitter)
DATA-TV Bölücüsü
2 yollu harici bölücü (splitter)
3 yollu harici bölücü (splitter)
4 yollu dahili dağıtıcı (tap-off)
6 yollu dahili dağıtıcı (tap-off)
8 yollu dahili dağıtıcı (tap-off)
2 yollu harici dağıtıcı (tap-off)
4 yollu harici dağıtıcı (tap-off)
8 yollu harici dağıtıcı (tap-off)
4 yollu harici dağıtıcı (tap-off / F-port enerji geçişli)
2 yollu ahtapot dağıtıcı (tap-off)
3 yollu ahtapot dağıtıcı (tap-off)
4 yollu ahtapot dağıtıcı (tap-off)
2 yollu ahtapot bölücü
Directional Coupler (DC)
Power Inserter
Galvanik Izolator
3,5/12 Konnektör (Tüm Yeraltı Kablolar İçin)
5,8”(PIN) Konnektör (Tüm Yeraltı Kablolar İçin)
Splice Konnektör (Tüm Yeraltı Kablolar İçin)
F-Male Konnektör (Tüm Yeraltı Kablolar İçin)
KES Konnektör (Tüm Yeraltı Kablolar İçin)
IEC Konnektör (Tüm Dahili Kablolar İçin)
F-F Konnektör
F-Male Konnektör (RG6 Kablolar İçin)
F-Male Konnektör (RG11 Kablolar İçin)
MCX Konnektör (CMTS Kablosu İçin)
F Kilitli Sonlandırma
F Sonlandırma
5/8” Sonlandırma
3,5/12 Sonlandırma
KES Tipi Sonlandırma
Kablo TV Saha UPS (380VA-48Vac)
12V-55Ah AKÜ
1000VA 19” Rack UPS
2000VA 19” Rack UPS
12V-9Ah AKÜ
12V-18Ah AKÜ
12V-100Ah AKÜ
100W-300W Micro UPS (FTTx/RFOG)
TKS-KAB-02
TKS-KAB-03
TKS-KAB-04
TKS-KAB-05
TKS-KAB-06
TKS-KAB-07
TKS-KAB-08
TKS-KAB-09
TKS-KAB-10
TKS-KAB-11
TKS-KAB-12
TKS-KAB-13
TKS-KAB-14
TKS-KAB-15
TKS-KAB-16
TKS-RFP-01
TKS-RFP-02
TKS-RFP-03
TKS-RFP-04
TKS-RFP-05
TKS-RFP-06
TKS-RFP-07
TKS-RFP-08
TKS-RFP-09
TKS-RFP-10
TKS-RFP-11
TKS-RFP-12
TKS-RFP-13
TKS-RFP-14
TKS-RFP-15
TKS-RFP-16
TKS-RFP-20
TKS-RFP-17
TKS-RFP-18
TKS-RFP-19
TKS-KON-01
TKS-KON-02
TKS-KON-03
TKS-KON-04
TKS-KON-05
TKS-KON-06
TKS-KON-07
TKS-KON-08
TKS-KON-09
TKS-KON-10
TKS-KON-11
TKS-KON-12
TKS-KON-13
TKS-KON-14
TKS-KON-15
TKS-ENJ-01
TKS-ENJ-02
TKS-ENJ-03
TKS-ENJ-04
TKS-ENJ-05
TKS-ENJ-06
TKS-ENJ-07
TKS-ENJ-08
123 / 126
UPS/NODE Dolabı UPS/NODE
DolabPS/NOD
RF YÜKSELTİCİLERİ
OPTİK TAŞIYICI ÜNİTELER
OPTİK BÖLÜCÜLER
CWDM MUX / DEMUX / FILTER
DWDM MUX / DEMUX / FILTER
WDM
1310nm MULTIWAVELENGHT
TRANSMITTER
C-BAND DWDM TRANSMITTER
NARROWCAST TRANSMITTER
OPTİK YÜKSELTİCİLER
GERİYÖN OPTİK RECEIVER
FIBER NODE
MALZEME
Bina Yükselticisi (BA-TİP585)
Hat Yükselticisi (HA-TİP585)
Hat Yükselticisi DOCSIS Yönetim Modülü
Aktif Optik Taşıyıcı Ünite (SubRack) - 2 Power Supply ve
Yönetim Modülü Dahil - 2RU/3RU/4RU
Pasif Optik Taşıyıcı Ünite (SubRack)-3RU/4RU/5RU
1:2 Optik Splitter
1:4 Optik Splitter
1:8 Optik Splitter
1:16 Optik Splitter
1:32 Optik Splitter
1:32 Aktif Optik Splitter
8 Kanal CWDM Mux-Demux
16 Kanal CWDM Mux-Demux
High/Low Band CWDM Filter
4 ITU GRID Kanal DWDM Mux-Demux
8 ITU GRID Kanal DWDM Mux-Demux
OADF/OADM (Optical Add Drop Filter/Mux)
Wavelenght Division Multiplexer (WDM-1)
Wavelenght Division Multiplexer (WDM-2)
1310nm MV 8 dBm Transmitter
1310nm MV 10 dBm Transmitter
1310nm MV 12 dBm Transmitter
C-Band ST Transmitter
C-Band EM Transmitter
Narrowcast Transmitter
1x13 dB EDFA
1x16 dB EDFA
4x20 dB EDFA
1x13 dB GFEDFA
1x16 dB GFEDFA
Geriyön Optik Receiver (2x2 Rx)
Geriyön Optik Receiver (4x4 Rx)
Geriyön RFOG Receiver (2x2 RFOG Rx)
Geriyön RFOG Receiver (4x4 RFOG Rx)
Fiber Node - 1x1FN (İAM, GVM ve DYM hariç)
Fiber Node - 2x2FN (İAM, GVM ve DYM hariç)
İleriyön alıcı modülü (İAM)
+3 dBm CWDM geriyön verici modülü (GVM)
+6 dBm CWDM geriyön verici modülü (GVM)
FN DOCSIS Yönetim Modülü (DYM)
FTTB Node
RFOG FN
1610nm OBI Free RFOG Node
Türksat Ürün
Numarası
TKS-RFY-01
TKS-RFY-02
TKS-RFY-03
TKS-OPS-01
TKS-OPS-02
TKS-OPS-03
TKS-OPS-04
TKS-OPS-05
TKS-OPS-06
TKS-OPS-07
TKS-OPS-40
TKS-OPS-08
TKS-OPS-09
TKS-OPS-10
TKS-OPS-11
TKS-OPS-12
TKS-OPS-13
TKS-OPS-14
TKS-OPS-15
TKS-OPS-16
TKS-OPS-17
TKS-OPS-18
TKS-OPS-19
TKS-OPS-20
TKS-OPS-21
TKS-OPS-22
TKS-OPS-23
TKS-OPS-24
TKS-OPS-25
TKS-OPS-26
TKS-OPS-27
TKS-OPS-28
TKS-OPS-29
TKS-OPS-30
TKS-OPS-31
TKS-OPS-32
TKS-OPS-33
TKS-OPS-34
TKS-OPS-35
TKS-OPS-36
TKS-OPS-37
TKS-OPS-38
TKS-OPS-39
124 / 126
MALZEME
GALVANİZLİ SAC DOLAPLAR
IP55 HARİCİ TİP
ALÜMİNYUM KABİNETLER
ÇEŞİTLİ MALZEMELER
Küçük BDK Dolabı
Büyük BDK Dolabı
IP 55 Fiber Node/UPS Saha Dolabı
Yükseltici Saha Dolabı (TİP B)
Pasif Saha Dolabı (TİP C)
IP 55 P-OTD (Pasif Optik Terminasyon Dolabı)
Saha Dolabı 700 lük
UPS Dolabı
UPS Dolabı Akü Koruma Kapağı
Outdoor TİP 190
Outdoor TİP 125
Outdoor TİP 80
Outdoor Kabin Isı Eşanjörü 60 W
Outdoor Kabin Isı Eşanjörü 80 W
Outdoor Kabin Isı Eşanjörü 110 W
Optik zayıflatıcı (1-10 dB)
Topraklı Priz (İkili)
Antigron Kablo NYM 3*2,5
Antigron Kablo NYM 3*1,5
V Otomat 6 A (Komple Kutulu Koruyuculu)
Yeraltı Enerji Kablosu-Zırhlı (4x10 mm²)
Topraklama kablosu
Asma kilit (Kilit, Asma Aparatı, Somun Cıvata dahil)
İzoleli Çelik Halat
Numaratör (Orjinal)
Kablo Bağı
Saha Dolabı Topraklama Çubuğu (Aparatları ile birlikte) 12x85
Saha Dolabı Topraklama Çubuğu (Aparatları ile birlikte) 15x100
Saha Dolabı Topraklama Çubuğu (Aparatları ile birlikte) 18x120
AĞAÇ DİREK L=8 m. ø=13 cm.
AĞAÇ DİREK L=10 m. ø=13 cm.
Basınç dayanım sınıfı C 25/30 (BS 25 B 300) olan hazır
beton
ASFALT
Büyük Parke Taşı (120-130mm)
Küçük Parke Taşı (80-100mm)
Mozaik Parke Taşı (50-60mm)
Galvaniz Boru 1/2
Galvaniz Boru 1
Galvaniz Boru 1-1/2
Yüksek Geçiren Filtre (High Pass Filter)
180 cm Ku Band Anten (Fiber katkılı polyester veya
alüminyum) (Ayak ve montaj aparatları dahil)
Profesyonel Quattro LNB
LO Stability: ±25 kHz
Noise figure: <1,2dB
LO Phase noise: -120 dBc @ >1 MHz
Türksat Ürün
Numarası
TKS-DLP-01
TKS-DLP-02
TKS-DLP-03
TKS-DLP-04
TKS-DLP-05
TKS-DLP-14
TKS-DLP-12
TKS-DLP-13
TKS-DLP-15
TKS-DLP-06
TKS-DLP-07
TKS-DLP-08
TKS-DLP-09
TKS-DLP-10
TKS-DLP-11
TKS-DGR-01
TKS-DGR-02
TKS-DGR-03
TKS-DGR-04
TKS-DGR-05
TKS-DGR-06
TKS-DGR-07
TKS-DGR-08
TKS-DGR-09
TKS-DGR-10
TKS-DGR-11
TKS-DGR-12
TKS-DGR-13
TKS-DGR-14
TKS-DGR-15
TKS-DGR-16
TKS-DGR-17
TKS-DGR-18
TKS-DGR-19
TKS-DGR-20
TKS-DGR-21
TKS-DGR-22
TKS-DGR-23
TKS-DGR-24
TKS-DGR-25
TKS-DGR-26
TKS-DGR-27
125 / 126
MALZEME
ÇEŞİTLİ MALZEMELER
19” RACK SİSTEM KABİNİ - 42 U (60X60 CM) 4 lü fan ve
10 lu grup priz dahil
19” RACK SİSTEM KABİNİ - 42 U (60X80 CM) 4 lü fan ve
10 lu grup priz dahil
PVC Kablo Kanalı (25x25)
PVC Kablo Kanalı (25x40)
240 CM KU BAND ANTEN (FİBER KATKILI POLYESTER
VEYA ALÜMİNYUM)
(AYAK VE MONTAJ APARATLARI DAHİL)
RF ZAYIFLATICI (1-10 dB)
50X40mm Galvanizli Metal Kablo Kanalı (1,5mm Et
kalınlığı)
PVC Kablo Kanalı 60x40
PVC Kablo Kanalı 80x40
4x16 Çelik Zırhlı Elektrik Kablosu
2x25A 30MA K.A.K. Rölesi
1*16 A C Otomat Sigorta
NH 00 Boy Yatay Yük Kesici
WGT 10 Topraklama Klemensi
25x30 Taban Saçlı Pano
19” RACK SİSTEM KABİNİ - 42 U (80X80 CM) 4 lü fan ve
2x18 li grup priz(otomat dahil) dahil
Parke Taşı
Galvanizli Boru 2
Türksat Ürün
Numarası
TKS-DGR-28
TKS-DGR-29
TKS-DGR-30
TKS-DGR-31
TKS-DGR-32
TKS-DGR-33
TKS-DGR-34
TKS-DGR-35
TKS-DGR-36
TKS-DGR-37
TKS-DGR-38
TKS-DGR-39
TKS-DGR-40
TKS-DGR-41
TKS-DGR-42
TKS-DGR-43
TKS-DGR-44
TKS-DGR-45
126 / 126

Benzer belgeler