Copenhagen - Eclipse Lighting Inc.
Transkript
Copenhagen - Eclipse Lighting Inc.
Copenhagen We reserve the right to revise the design or components of any product without notice. EURO WALL PACK FAMILY; Surface Mount; Vandal Resistant HID, CFL, LED CATALOG # TYPE PROJECT/LOCATION APPROVED BY STYLE A SPECIFICATIONS STYLE B • REFLECTOR — .032 aluminum For High Efficiency • BALLAST — For Compact Fluorescent Electronic Cold Weather HPF is Standard. For HID Pulse Start is Standard. • DIFFUSER — Opal White Injection Molded Polycarbonate Standard. Optional Ribbed Clear (RC) or Frosted (RF) Prismatic Polycarbonate. • EMERGENCY — CFL, LED — Remote Only. • FASTENERS — (4) Stainless steel tamperproof Torx screws to secure lens to backplate • FINISH — Extremely durable oven baked Polyester Powder coat – Finishes include Black, Bronze or White. • GASKETING — One Piece Die Cut 3/16” Thick Black EPDM and/or neoprene rubber. STYLE D • HOUSING — Cast aluminum with injection-molded polycarbonate trim and diffuser. • LAMP — LED, Double Twin Tube or Triple Twin Tube mini-fluorescent; Medium Base Metal Halide STYLE C (Deep Cast only) as required — by others. • MOUNTING HOLES — (4) 5/16” Diameter Holes for 1/4” Diameter Bolts. • COMPLIANCE — Built to comply with U.S. and Canadian safety standards. Suitable for wet locations (requires 4-point mounting). STYLE E STYLE F DIMENSIONS 12" 1/2" 3-1/2" 12" 2-7/8" 5-7/8" 13-7/8" 4-1/3" 7-1/3" 9245 W. Ivanhoe St. I Schiller Park, IL 60176 P: 847-260-0333 I F:847-260-0344 I E: [email protected] I W: eclipselightinginc.com 8-7/8" © 2016 Eclipse Lighting Inc. Eclipse Lighting pg.55 Rev. Jun 1, 2016 Copenhagen LAMP TYPE/QTY/WATTAGE ❶ Visit www.eclipselightinginc.com for available IES files Fixture EURO WALL PACK FAMILY; Surface Mount; Vandal Resistant HID, CFL, LED Series Style COPENHAGEN Shallow COPENHAGEN Mid-Depth COPENHAGEN Deep 14” x 9” x 3½” (ADA) 14” x 9” x 6” 14” x 9” x 7½” (1 or 2)13w; (1)26w (1 or 2)13/26w (1 or 2)26w (1)26/32w (1 or 2)26/32; (1)42w (1 or 2)26/32w; (1)42w Dimensions - W x H x D (nominal) Compact Fluorescent DTT Double Twin Tube Compact Fluorescent TTT Triple Twin Tube Pulse Start Metal Halide MH N/A N/A 50/70w Light Emitting Diode LED 15w 20/35w 20/30/35w Lamp Type/Qty/Watt Color Temp Voltage: Primary/Emergency Finish Options ORDERING GUIDE: SERIES FINISH CP-S=Copenhagen Shallow Casting Series (4” deep, ADA)—Not for Use with Surface Conduit Entry CP-M = Copenhagen Mid-Depth Casting Series (6-1/2” deep) CP-D = Copenhagen Deep Casting Series (8” deep) STYLE A B C D E F = Style A: with Cage = Style B: no Cage = Style C: Horizontal Eyelid with Vertical Bar = Style D: Vertical Eyelid with Vertical Bar = Style E: Horizontal Eyelid 2 - no Bar = Style F: Vertical Eyelid 2 - no Bar No onsite Emergency Power (AC or DC) is provided Specify Fixture Voltage: 120V or 277V Power Feed A=120V or B=277V COLOR WINDOW EL2 = Integral (CP-M, CP-D); (1)TTT; 650 Lms REL2 = Remote: TTT; 1-2 Lamp; 650 Lms REL35 = Remote, Cold Weather TTT; 1-2 Lamp; 1250 Lms *SPECIFY FRONT/SIDES/BOTH AM =Amber BLU =Blue CC =Custom Color (Consult Factory) GN =Green OPL =Translucent Opal White RD =Red VOLTAGE LED COLOR TEMPERATURE LED OPTIONS Refer to Chart Above 120 =120 Volts 277 =277 Volts 347 =347 Volts (Consult Factory for “S” size) EBMH=Electronic Ballast for Metal Halide EBU=Universal Volt (120-277v) 3K =±3000K range LED (120 Initial LPW) 4K =±4000K range LED (132 Initial LPW) 5K =±5000K range LED (140 Initial LPW) 6K =±6000K range LED (145 Initial LPW) Fluorescent Emergency Battery OPTIONS 9002 9206 9221 9328 FUS DFUS GTD RC RF LAMP TYPE/QUANTITY/WATTAGE EMERGENCY BATTERY OPTIONS❸ BK =Black—Standard BZ =Bronze WH =White SGR =Titanium Silver Gray = Torx Tamperproof Screwdriver = Photocell – 120V = Photocell – 277V = Universal Photocell – 120/277V = Single Fusing = Double Fusing = Generator Transfer Device (Bodine) = Ribbed Clear Prism. Polycarbonate Diffuser = Ribbed Frosted Opal Diffuser BL = Dual Circuit for Bi-Level light (High/Low), includes 2EBU D7 = 0-10V low-voltage dimming (100-30% Standard, Consult Factory for Other) MSE = Motion Sensor External —Single circuit-all on, all off Specify Finish: White (WH)/Bronze (BZ) MSE2 = Motion Sensor External — Dual circuit, half on half off Specify Finish: White (WH)/Bronze (BZ) SG = 10KA Surge Protection for LED fixtures Available CP-M and CP-D Only (meets ANSI spec C62.41.2) LED Emergency Battery REL61 =Remote: LED 12W, ± 720 Lms (by Iota) REL63 =Remote: LED 23W, ± 1290 Lms (Bodine) REL67 =Remote, Cold Weather LED 23W, ± 1290 Lms (Iota) REL82=Remote: LED 4W (Fulham) —Factory Recom'd REL85 =Remote: LED 20W (Fulham) —Factory Recom'd REL88=Remote: LED 16W (Fulham) —Factory Recom'd LED EMERGENCY CIRCUIT Onsite Generator Power (AC) or Battery Power (DC) is provided via separate circuit to the fixture NOTES: ❶ Consult Factory with requests regarding lamp sources, including LED, color temp., wattages or voltages not shown. ❷ Emergency Battery (EL) includes Backbox ❸ Consult Factory for additional Emergency Battery options. Max WHIP length with the REL provided by the factory is 8 feet. EC1A = (1) 5W LED for Line Voltage (120VAC) EC2A = (1) 5W LED for Line Voltage (277VAC) EC3A = (2) 5W LED for Line Voltage (120VAC) EC4A = (2) 5W LED for Line Voltage (277VAC) EC1D = (1) 5W LED for Low Voltage (12VDC) EC2D = (1) 5W LED for Low Voltage (24VDC) EC3D = (2) 5W LED for Low Voltage (12VDC) EC4D = (2) 5W LED for Low Voltage (24VDC) Consult Factory for other Voltage. Due to form and fit, final selection of the Battery Pack under discretion of Factory © 2016 Eclipse Lighting Inc. pg.56 Eclipse Lighting Rev. Jun 1, 2016 9245 W. Ivanhoe St. I Schiller Park, IL 60176 P: 847-260-0333 I F:847-260-0344 I E: [email protected] I W: eclipselightinginc.com